Cited by 117Silk-based biomaterials and applicationsElectrospun Nanofibers in Biomedical ApplicationsBone Tissue Engineering Materials

The DOI matches its Crossref record.

Preparation of 3-D regenerated fibroin scaffolds with freeze drying method and freeze drying/foaming technique

Lv, Qiang, Feng, QingLing·2006·Journal of Materials Science: Materials in Medicine

Abstract

Although three-dimensional fibroin scaffolds have been prepared with freeze drying method, the porosity and pore sizes still can not satisfy the requirement of tissue engineering. In this article, fibroin porous scaffold with high porosity and > 100 microm diameter interconnected pores was firstly prepared with freeze drying method through adjusting fibroin concentration. The morphology of different scaffolds lyophilized from different fibroin concentration was observed by SEM. A novel freeze drying improved method, freeze drying/foaming technique, was also devised to prepare fibroin scaffolds at different fibroin concentrations. Using the said method, the porosity and pore size of fibroin scaffolds prepared from 12% concentration were 85.8 +/- 4% and 109 +/- 20 microm respectively with yield strength up to 450 +/- 6 KPa while the porosity and pore size of fibroin scaffolds prepared from 8% concentration were 96.9 +/- 3.6% and 120 +/- 30 microm respectively with yield strength up to 30 +/- 1 KPa. The freeze drying/foaming technique produced scaffolds with a useful combination of high yield strength, interconnected pores, and pore sizes greater than 100 microm in diameter. Through adjusting fibroin concentration and thawing time, the porosity, pore sizes and mechanical properties could be controlled to satisfy the different requirements of tissue engineering. The results suggested that fibroin scaffolds prepared with the above methods could be formed for utility in biomaterial application.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10856-006-0610-z

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Silk fibroin sponge-like porous scaffolds are prepared through methods such as freeze-drying, salt leaching, and chemical crosslinking.

    “Silk fibroin sponge-like porous scaffolds are prepared through methods such as freeze-drying, salt leaching, and chemical crosslinking [38,62,63].”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 18

  1. R. LANGER and J. P. VACANTI, Tissue Eng. Sci. 260 (1993) 920–926.
  2. R. M. NEREM and A. SAMBANIS, Tissue engineering: From biology to biological substitutes. Tissue Eng. 1 (1995) 3–13. · DOI
  3. C. MAULI AGRAWAL and ROBERT B. Ray, Biodegrable polymeric scaffolds for musculoskeletal tissue engineering. J. Biomed. Mater. Res. 55 (2001) 141–150. · DOI
  4. C. J. LIAO., C. F. CHEN, J. H. CHEN, S. F. CHIANG, Y. J. LIN, K. Y. CHANG, Fabrication of porous biodegradable polymer scaffolds using a solvent merging/particulate leaching method. J. Biomed. Mater. Res. 59 (2002) 676–681. · DOI
  5. SUSAN SOFIA, MARY BETH MCARTHY, GLORIA GRONOWICZ and DAVID L. KAPLAN, Functionalized silk-based biomaterials for bone formation. J. Biomed. Mater. Res. 54 (2001) 139–148. · DOI
  6. J. PÉREZ-RIGUEIRO, C. VINEY, J. LLORCA and M. ELICES, Silkworm silk as an engineering material. J. Appl. Polym. Sci. 70 (1998) 2439–2447. · DOI
  7. UNGER RONALD E, WOLF MICHAEL, PETERS KIRSTEN, MOTTA ANTONELLA, MIGIARESI CLAUDIO and JAMES KIRKPATRICK C, Growth of human cells on a non-woven silk fibroin net: a potential for use in tissue engineering. Biomaterials 25 (2004) 1069–1075. · DOI
  8. H. ALTMAN GREGORY, L. HORAN REBECCA, H. LU HELEN, JODIE MOREAU, IVAN MARTIN and C. JOHN RICHMOND, Silk matrix for tissue engineered anterior cruciate ligaments. Biomaterials 23 (2002) 4131–4141. · DOI
  9. YOHKO GOTOH, SHINGO NIIMI, TAKAO HAYAKAWA and TOKUJI MIYASHITA, Preparation of lactose-silk fibroin conjugates and their application as a scaffold for hepatocyte attachment. Biomaterials 25 (2004) 1131–1140. · DOI
  10. A. G. MIKOS, Y. BAO, L. G. CIMA, D. E. INGBER, J. P. VACANTI and R. LANGER, Preparation of poly(glycolic acid) bonded fibers structures for cell attachment and transplantation. J. Biomed. Mater. Res. 27 (1993) 183–189. · DOI
  11. M. C. WAKE, P. K. GUPTA and A. G. MIKOS, Fabrication of pliable biodegradable polymer foams to engineer soft tissues. Cell Transplant 5 (1996) 465–473. · DOI
  12. R. A. GIORDANO, B. M. WU, S. W. BORLAND, L. G. CIMA, E. M. SACHS and M. J. CIMA, Mechanical properties of dense polylactic acid structures fabricated by three dimensional printing. J. Biomater. Sci. Polym. Ed. 8 (1996) 63–75. · DOI
  13. D. J. MOONEY, D. F. BALDWIN, N. P. SUH, J. P. VACANTI and R. LANGER, Novel approach to fabricate porous sponges of poly(D, L-lactic-co-glycolic acid) without the use of organic solvents. Biomaterials 17 (1996) 1417–1422. · DOI
  14. LI. MINGZHONG, WU. ZHENGYU, ZHANG CHANGSHENG, LU. SHENZHOU, YAN HAOJING, HUANG DONG and YE. HUILAN, Study on porous silk fibroin materials. II. Preparation and characteristics of spongy porous silk fibroin materials. J. Appl. Polym. Sci. 79 (2001) 2192–2199. · DOI
  15. YOON SUNG NAM and TAE GWAN PARK, Porous biodegradable polymeric scaffolds prepared by thermally induced phase separation. J. Biomed. Mater. Res. 47 (1999) 8–17. · DOI
  16. RINA NAZAROV, HYOUNG JOON JIN and DAVID L. KAPLAN, Porous 3-D scaffolds from regenerated silk fibroin. Biomacromolecules 5 (2004) 718–726. · DOI
  17. Q. LU, C. B. CAO, Y. ZHANG, X. L. MA and H. S. ZHU, Preparation and properties of insoluble fibroin films by novel method. Chem. J. Chinese Univ. 25 (2004) 1752–1755.
  18. LI. MINGZHONG, LU. SHENZHOU, WU. ZHENGYU, YAN HAOJING, MO. JINGYU and WANG LIHONG, Study on porous silk fibroin materials. I. Fine structure of freeze dried silk fibroin. J. Appl. Polym. Sci. 79 (2001) 2185–2191. · DOI

Cited by

Sorted by citations

Metadata

Authors
Lv, Q., & Feng, Q.
Affiliations
Tsinghua University (CN)
Corresponding author
Feng, QingLing
Venue
Journal of Materials Science: Materials in Medicine
Published
2006-12
Volume
17
Issue
12
Pages
1349-1356
ISSN
  • 0957-4530 (ISSN-L)
  • 1573-4838
OpenAlex
W2029284022
Cited by
117
References
0
Citations by year
2026: 4 · 2025: 6 · 2024: 5 · 2023: 1 · 2022: 6 · 2021: 11 · 2020: 7 · 2019: 9 · 2018: 6 · 2017: 7 · 2016: 6 · 2015: 5 · 2014: 10 · 2013: 4 · 2012: 3
FWCI
2.94
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Materials Science Materials in Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China
  • Tsinghua University
Topics
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
freeze-drying, porosity, pore size, interconnected pores, yield strength, mechanical properties, tissue engineering scaffolds, biomaterials
MeSH terms
Animals, Biocompatible Materials, Fibroins, Freeze Drying, Microscopy, Electron, Scanning, Bombyx, Solutions, Porosity, Tissue Engineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review