Artificial Neural Network Based Epileptic Detection Using Time-Domain and Frequency-Domain Features
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Electroencephalogram (EEG) signal plays an important role in the diagnosis of epilepsy. The long-term EEG recordings of an epileptic patient obtained from the ambulatory recording systems contain a large volume of EEG data. Detection of the epileptic activity requires a time consuming analysis of the entire length of the EEG data by an expert. The traditional methods of analysis being tedious, many automated diagnostic systems for epilepsy have emerged in recent years. This paper discusses an automated diagnostic method for epileptic detection using a special type of recurrent neural network known as Elman network. The experiments are carried out by using time-domain as well as frequency-domain features of the EEG signal. Experimental results show that Elman network yields epileptic detection accuracy rates as high as 99.6% with a single input feature which is better than the results obtained by using other types of neural networks with two and more input features.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032 · cited 5×
“The subjects are relaxed in an awaken state with eyes open.(10) Depth electrodes are implanted symmetrically into the hippocampal formations and strip electrodes are implanted into the lateral and basal regions (middle and bottom) of the neocortex.”
BackgroundMethodInfluentialAutomatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674 · cited 5×
“The method proposed by Weng and Khorasani(5) uses the features proposed by Gotman,(6) namely, average EEG amplitude, average EEG duration, coefficient of variation, dominant frequency, and average power spectrum as inputs to an adaptive structured neural network.”
BackgroundMethodInfluentialDescription of the Entropy™ algorithm as applied in the Datex‐Ohmeda S/5™ Entropy Module
Viertiö‐Oja, H., Maja, V., Särkelä, M., Talja, P., Tenkanen, N., Tolvanen‐Laakso, H., Paloheimo, M., Vakkuri, A., Yli‐Hankala, A., & Meriläinen, P. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.00322.x · Cited by 582 · cited 3×
“( 9 ) The last feature, namely, normalized spectral entropy has been so far”
BackgroundMethodInfluentialA neural-network-based detection of epilepsy
Nigam, V. P., & Graupe, D. (2004) · Neurological Research · doi:10.1179/016164104773026534 · Cited by 350 · cited 10×
“The overall detection accuracy rate obtained in this case is about 99.6%, which is better than the overall detection accuracy of 98.4% obtained with the LAMSTAR neural network(8) using two time-domain features, namely, spike rhythmicity and relative spike amplitude as the inputs.”
BackgroundMethodInfluentialQu, H., & Gotman, J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.552241 · Cited by 248 · cited 9×
“(4) APMEZ is obtained by dividing the power in this band by its width.(4) The spectral entropy (SE)(9) corresponding to the frequency range [f1, f2] is calculated for each epoch of the EEG signal using equation (2)”
BackgroundMethodInfluentialDetection of Seizure Activity in EEG by an Artificial Neural Network: A Preliminary Study
Pradhan, N., Puthusserypady, S. K., & Arunodaya, G. R. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0022 · Cited by 143 · cited 5×
“The method proposed by Pradhan et al.(7) uses raw EEG signal as input to a learning vector quantization (LVQ) network.”
BackgroundMethodInfluentialState-dependent spike detection: concepts and preliminary results
Gotman, J., & Wang, L. Y. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90151-s · Cited by 129 · cited 5×
“The method proposed by Weng and Khorasani(5) uses the features proposed by Gotman,(6) namely, average EEG amplitude, average EEG duration, coefficient of variation, dominant frequency, and average power spectrum as inputs to an adaptive structured neural network.”
BackgroundMethodInfluentialAn Adaptive Structure Neural Networks with Application to EEG Automatic Seizure Detection
Weng, W., & Khorasani, K. (1996) · Neural Networks · doi:10.1016/0893-6080(96)00032-9 · Cited by 107 · cited 6×
“The dominant frequency (DF)(5) is the most important characteristic for each epoch of the EEG signal in the frequency-domain.”
BackgroundMethodInfluentialComputerized seizure detection of complex partial seizures
Murro, A. M., King, D. W., Smith, J. R., Gallagher, B. B., Flanigin, H. F., & Meador, K. J. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90128-q · Cited by 92 · cited 3×
“The normalized spectral entropy (NSE) is obtained by dividing SE by a factor log (N) where N is equal to the total number of frequency components in the range [f1, f2] as defined in equation (3).”
BackgroundMethodInfluentialKıymık, M. K., Subaşı, A., & Özçalık, H. R. (2004) · Journal of Medical Systems · doi:10.1023/b:joms.0000044954.85566.a9 · Cited by 64 · cited 1×
“The frequency domain features employed in this work is based on the periodogram pre-processing approach and hence would be more suitable for real time applications as they require less overall processing time.(13)”
Method
Research works printed but not linked: 1
- Demuth, H., and Beale, M., Neural Network Toolbox (for use with Matlab), Mathworks, Natick, Massachusetts, 2000.
Cited by
Automated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
“[103] Time & frequency domain features Elman network 99.”
BackgroundEpileptic Seizure Detection in EEGs Using Time–Frequency Analysis
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2017939 · Cited by 744
“Principal component analysis (PCA), using 1% threshold, was employed to reduce the dimension of the feature set [44] resulting in three to four features in all cases.”
MethodOrhan, U., Hekim, M., & Ozer, M. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.04.149 · Cited by 645
“Subasi (2007) found that ME and MLPNN models classified healthy segments and epileptic seizure segments with the accuracy of 94.”
Automated diagnosis of epileptic EEG using entropies
Acharya, U. R., Molinari, F., Sree, S. V., Chattopadhyay, S., Ng, K.-H., & Suri, J. S. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.07.007 · Cited by 626
“[59] Time and frequency domain features – Recurrent neural network 99.”
Approximate Entropy-Based Epileptic EEG Detection Using Artificial Neural Networks
Srinivasan, V., Eswaran, C., & Sriraam, N. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.884369 · Cited by 591
“It can be concluded from the results that, in general, EN performs better than PNN for almost for all the combinations of m, r, and N. The feedback configuration and the incremental training process associated with the EN may be considered as possiblereasonsforitssuperiorperformance.Theoveralldetection accuracy values…”
MethodInfluentialSelf-citation
Metadata
- Authors
- Srinivasan, V., Eswaran, C., & Sriraam, A. N.
- Affiliations
- Multimedia University (MY)
- Corresponding author
- Srinivasan, V.
- Venue
- Journal of Medical Systems
- Published
- 2005-12
- Volume
- 29
- Issue
- 6
- Pages
- 647-660
- ISSN
- 0148-5598 (ISSN-L)
- 1573-689X
- OpenAlex
- W1989801867
- Cited by
- 417
- References
- 12
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 15 · 2023: 10 · 2022: 20 · 2021: 29 · 2020: 36 · 2019: 36 · 2018: 43 · 2017: 42 · 2016: 26 · 2015: 27 · 2014: 30 · 2013: 20 · 2012: 17
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Medical Systems (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- seizure detection, EEG signals, Elman neural network, time-domain features, frequency-domain features
- MeSH terms
- Electroencephalography, Epilepsy, Humans, Seizures, Signal Processing, Computer-Assisted, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Neural Network Based Epileptic Detection Using Time-Domain and Frequency-Domain Features. https://app.cochat.ai/papers/10.1007/s10916-005-6133-1
- The paper
- Srinivasan, V., Eswaran, C., & Sriraam, A. N. (2005). Artificial Neural Network Based Epileptic Detection Using Time-Domain and Frequency-Domain Features. Journal of Medical Systems. https://doi.org/10.1007/s10916-005-6133-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.