The development of emissivity measurements under vacuum at the PTB

Adibekyan, A. R., Monte, C., Kehrt, M., Morozova, S. P., Gutschwager, B., Hollandt, J.·2013·Measurement Techniques

Overview

Integrity signals

Registry

Crossref · 10.1007/s11018-012-0103-z

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Adibekyan et al. system used liquid nitrogen to cool the system and a Fourier-transform infrared spectrometer (FTIR) to acquire radiation signals.

    “Liquid-nitrogen was used to cool the system, and a Fourier-transform infrared spectrometer (FTIR) was employed to acquire radiation signals.”
  • Adibekyan et al. (2013) developed an emissivity measurement apparatus operable above 173 K and covering the 4.5-20 μm wavelength range.

    “In 2013, Adibekyan et al. [49] developed an emissivity measurement apparatus operable above 173 K and covering the 4.5-20 µm wavelength range.”
  • The evolution of radiometric methods reveals a trend in cooling methods from reliance on external cryogenic liquids (such as liquid nitrogen and liquid helium) to integrated refrigeration systems.

    “Initially, cooling methods evolved from reliance on external cryogenic liquids [17,44,49,55], such as liquid nitrogen and liquid helium, to integrated refrigeration system [37,54].”
  • There has been a transition in the arrangement of key optical paths from external detectors to fully integrated designs.

    “Secondly, there has been a transition in the arrangement of key optical paths from external detectors [17,37,49,55] to fully integrated designs [54].”

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 5

  1. C. Monte et al., “Radiation thermometry and emissivity measurements under vacuum at the PTB,” Int. J. Thermophys., 30, 203–219 (2009). · DOI
  2. S. P. Morozova et al., “Vacuum variable temperature black body VLTBB100,” Int. J. Thermophys., 29, 341–351 (2008). · DOI
  3. S. P. Morozova et al., “Vacuum variable medium temperature black body VLTBB100,” Int. J. Thermophys., 31, 1809–1820 (2010). · DOI
  4. C. Monte and J. Hollandt, “The measurement of directional spectral emissivity in the temperature range from 80°C to 400°C at the Physikalisch-Technische Bundesanstalt,” High Temp. – High Press., 39, 151–164 (2010).
  5. C. Monte and J. Hollandt, “The determination of the uncertainties of spectral emissivity measurements in air at the PTB,” Metrologia, 47, S172–S181 (2010). · DOI

Cited by

Sorted by citations

Metadata

Authors
Adibekyan, A. R., Monte, C., Kehrt, M., Morozova, S. P., Gutschwager, B., & Hollandt, J.
Venue
Measurement Techniques
Published
2012-12-21
Volume
55
Issue
10
Pages
1163-1171
ISSN
  • 0543-1972
  • 1573-8906
Cited by
6
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review