Single-Dose Intravenous Toxicity Study of IRDye 800CW in Sprague-Dawley Rats
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Fluorophore-labeled contrast imaging agents are moving toward clinical use for a number of applications. The near-infrared dye IRDye 800CW is frequently used in its N-hydroxysuccinamide (NHS) ester form for labeling these agents. Following conjugation or breakdown of a labeled ligand, excess NHS ester is converted to the carboxylate form. To prepare for clinical use as a near-infrared fluorophore, a toxicity study was conducted on IRDye 800CW carboxylate. METHODS: Male and female Sprague-Dawley rats were given a single intravenous or intradermal administration of IRDye 800CW carboxylate; Indocyanine Green was used as a comparative control. Animals were injected with varying doses of the test and control articles and observed for up to 14 days. Clinical chemistry, hematological, and pharmacokinetic analyses were performed on subgroups of animals. Organs were analyzed for content of the test article. Tissues were analyzed microscopically for pathological changes. RESULTS: Based on hematologic, clinical chemistry, and histopathologic evaluation, single administration of IRDye 800CW carboxylate intravenously at dose levels of 1, 5, and 20 mg/kg or 20 mg/kg intradermally produced no pathological evidence of toxicity. CONCLUSION: A dose of 20 mg/kg was identified as the no observed adverse effect level following IV or ID routes of administration of IRDye 800CW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677 · cited 1×
“Indocyanine green (ICG) has been used for decades as an angiographic contrast agent and has been recently translated to the clinic for noninvasive lymph mapping [3–6].”
MethodAdverse Reactions due to Indocyanine Green
Hope-Ross, M., Yannuzzi, L. A., Gragoudas, E. S., Guyer, D. R., Slakter, J. S., Sorenson, J. A., Krupsky, S., Orlock, D. A., & Puliafito, C. A. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31303-0 · Cited by 631
Retinal Damage from Indocyanine Green in Experimental Macular Surgery
Gandorfer, A., Haritoglou, C., Gandorfer, A., & Kampik, A. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.02-0545 · Cited by 266 · cited 1×
“In these studies, however, the dose of ICG was significantly above the clinical dose in humans [23–27].”
BackgroundTanaka, E., Choi, H. S., Fujii, H., Bawendi, M. G., & Frangioni, J. V. (2006) · Annals of Surgical Oncology · doi:10.1245/s10434-006-9194-6 · Cited by 262 · cited 3×
“Tanaka et al. [ 9 ] reported the successful use of IRDye 800CW-labeled human serum albumin for sentinel lymph node mapping and surgical resection of spontaneous metastatic melanomas in Sinclair minipigs.”
BackgroundMethodInfluentialLymphatic imaging in humans with near-infrared fluorescence
Rasmussen, J. C., Tan, I.-C., Marshall, M. V., Fife, C. E., & Sevick-Muraca, E. M. (2009) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2009.01.009 · Cited by 219 · cited 2×
“The fluorescence-assisted resection and exploration instrumentation system described by Tanaka [10], the optical system described by Sevick-Muraca and coworkers [8, 9], and the Artemis (O2View, Marken, the Netherlands) also have great potential for NIR fluorescence molecular imaging.”
BackgroundMethodSelf-citationSampath, L., Kwon, S., Ke, S., Wang, W., Schiff, R., Mawad, M. E., & Sevick-Muraca, E. M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.042234 · Cited by 191 · cited 2×
“The fluorescence-assisted resection and exploration instrumentation system described by Tanaka [ 10 ], the optical system described by Sevick-Muraca and coworkers [8, 9], and the Artemis (O2View, Marken, the Netherlands) also have great potential for NIR fluorescence molecular imaging.”
MethodSelf-citation(1998) · Ophthalmology · doi:10.1016/s0161-6420(98)98048-4 · Cited by 158
Houston, J. P., Shi, K., Wang, W., Li, C., & Sevick-Muraca, E. M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2114748 · Cited by 107 · cited 1×
“[11] compared gamma scintigraphy and NIR fluorescence imaging using a dual-labeled cyclic RGD motif to show that on a 1:1 labeling basis, the NIR fluorescence from IRDye 800CW provided greater signal to noise than the radiotracer (111)In, even though camera integration times were hundreds of milliseconds rather than m…”
BackgroundSelf-citationIntegrated studies of biology: multiplexed imaging assays from molecules to man and back
Eliceiri, K. W., & Contag, C. H. (2009) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2009.04.001 · Cited by 99
Near‐Infrared Fluorescence Optical Imaging and Tomography
Gurfinkel, M., Shi, K., Wen, X., Li, C., & Sevick-Muraca, E. M. (2004) · Disease Markers · doi:10.1155/2004/474818 · Cited by 89
Self-citation
Cited by
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Liu, J., Yu, M., Zhou, C., Yang, S., Ning, X., & Zheng, J. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401612x · Cited by 597
Beyond the margins: real-time detection of cancer using targeted fluorophores
Zhang, R. R., Schroeder, A. B., Grudzinski, J. J., Rosenthal, E. L., Warram, J. M., Pinchuk, A. N., Eliceiri, K. W., Kuo, J. S., & Weichert, J. P. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.212 · Cited by 485
Safety and Tumor Specificity of Cetuximab-IRDye800 for Surgical Navigation in Head and Neck Cancer
Rosenthal, E. L., Warram, J. M., de Boer, E., Chung, T. K., Korb, M. L., Brandwein-Gensler, M., Strong, T. V., Schmalbach, C. E., Morlandt, A. B., Agarwal, G., et al. (2015) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-14-3284 · Cited by 469
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
Self-citationTranslation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
Sevick-Muraca, E. M. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-070910-083323 · Cited by 339
Self-citationTerwisscha van Scheltinga, A. G. T., van Dam, G. M., Nagengast, W. B., Ntziachristos, V., Hollema, H., Herek, J. L., Schröder, C. P., Kosterink, J. G. W., Lub-de Hoog, M. N., & de Vries, E. G. E. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092833 · Cited by 202
Cyanine polyene reactivity: scope and biomedical applications
Gorka, A. P., Nani, R. R., & Schnermann, M. J. (2015) · Organic & Biomolecular Chemistry · doi:10.1039/c5ob00788g · Cited by 179
Crane, L. M. A., Themelis, G., Arts, H. J. G., Buddingh, K. T., Brouwers, A. H., Ntziachristos, V., van Dam, G. M., & van der Zee, A. G. J. (2011) · Gynecologic Oncology · doi:10.1016/j.ygyno.2010.10.009 · Cited by 176
Zhao, M., Wang, R., Li, B., Fan, Y., Wu, Y., Zhu, X., & Zhang, F. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201812878 · Cited by 171
Li, S., Goins, B., Zhang, L., & Bao, A. (2012) · Bioconjugate Chemistry · doi:10.1021/bc300175d · Cited by 168
Metadata
- Authors
- Marshall, M. V., Draney, D., Sevick-Muraca, E. M., & Olive, D. M.
- Venue
- Molecular Imaging and Biology
- Published
- 2010-04-08
- Volume
- 12
- Issue
- 6
- Pages
- 583-594
- ISSN
- 1536-1632 (ISSN-L)
- 1860-2002
- OpenAlex
- W2028946041
- Cited by
- 231
- References
- 13
- FWCI
- 15.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.