Cited by 32Medical Imaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsCardiac Imaging and Diagnostics

Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI

Minamimoto, Ryogo, Levin, Craig, Jamali, Mehran, Holley, Dawn, Barkhodari, Amir, Zaharchuk, Greg, Iagaru, Andrei·2016·Molecular Imaging and Biology

Abstract

Purpose An integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) scanner with time of flight (TOF) technology is now available for clinical use. The aim of this study is to evaluate the potential of TOF PET in PET/MRI to reduce artifacts in PET images when compared to non-TOF PET/MRI, TOF PET/X-ray computed tomography (CT), and non-TOF PET/CT. Procedures All patients underwent a single 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) injection, followed first by PET/CT, and subsequently by PET/MRI. PET/CT exams were requested as standard-of-care for oncological indications. Using the PET acquisitions datasets, 4 series of images (TOF PET/CT, non-TOF PET/CT, TOF PET/MRI, and non-TOF PET/MRI) were reconstructed. These image series were visually evaluated for: (1) dental metal artifacts, (2) breathing artifacts, and (3) pelvic artifacts due to scatter correction errors from high bladder [(18)F]FDG concentration. PET image quality was assessed by a 3-point scale (1-clinically significant artifact, 2-non clinically significant artifact, and 3-no artifact). Results Twenty-five patients (mean ± SD age: 56 ± 13 years old; female: 10, male: 15) were enrolled. TOF PET/MRI, non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT scores 2.8, 2.5, 2.4, and 2.3, respectively for the presence of dental artifacts, 2.8, 2.5, 2.2, and 1.9, respectively, for the presence of breathing artifacts, and 2.7, 1.7, 2.0, and 1.3, respectively, for the presence of pelvic artifacts TOF PET…

Integrity signals

Registry

Crossref · 10.1007/s11307-016-0939-8

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Compared to standard OSEM reconstruction, OSEM with TOF shows improved noise characteristics.

    “Compared to standard ordered subset expectation maximization (OSEM) reconstruction, OSEM with TOF shows improved noise characteristics [49,94,156,157,158].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [156]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 26 · Cited by 32

Authors
Minamimoto, R., Levin, C., Jamali, M., Holley, D., Barkhodari, A., Zaharchuk, G., & Iagaru, A.
Affiliations
  • Stanford Medicine (US)
  • Stanford University (US)
Corresponding author
Iagaru, Andrei
Venue
Molecular Imaging and Biology
Published
2016-02-16
Volume
18
Issue
5
Pages
776-781
ISSN
  • 1536-1632 (ISSN-L)
  • 1860-2002
OpenAlex
W2283437346
Cited by
32
References
26
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 7 · 2017: 11 · 2016: 2
FWCI
6.36
Type
journal article
Language
en
Open access
closed
Locations
  • Molecular Imaging and Biology (publishedVersion)
  • PubMed (publishedVersion)
Funders
General Electric
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
time-of-flight PET, PET/MRI, PET image quality, breathing artifacts, scatter correction, 18F-FDG, PET/CT comparison, timing resolution
MeSH terms
Positron Emission Tomography Computed Tomography, Adult, Aged, Aged, 80 and over, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Time Factors, Tomography, X-Ray Computed, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review