A randomized, controlled, crossover study of a noncustomized tongue retaining device for sleep disordered breathing
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Tongue retaining devices (TRDs) are one type of oral appliance used to treat sleep disordered breathing. Previous studies have evaluated customized TRDs in comparison to mandibular repositioner appliances. The purpose of this study was to evaluate a noncustomized TRD compared to a control device. A randomized, controlled, crossover design was utilized. The primary outcome was the difference in reduction of the respiratory disturbance index (RDI) between the active suction device (S) and the control, nonsuction device (NS). Secondary outcomes included snoring index, Epworth Sleepiness Scale as well as patient and partner quality-of-life index. Crossover analysis found that only the S device significantly reduced the RDI by 4.9 (95% confidence interval 0.85-8.9) events more than the NS device. This represented a reduction in mean RDI from baseline of 15.5 (+/-17.6) to 8.9 (+/-7.6) with the S device. Significant reduction in snoring index was also only found with the S device (214.7-132.9 per hour). Fifty-four percent of subjects indicated they would continue to use only the S device. The S device, with suction, showed better objective and subjective outcomes. Future studies are needed to evaluate these types of devices in larger populations with a wide range of disease severity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“One randomised controlled trial showed significant effects from TRD on sleep apnoeas compared with a control device in patients with mild to moderate sleep apnoea 103.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [103]
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 1×
“The ESS is a questionnaire commonly used to assess daytime sleepiness [19].”
MethodThe Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“Symptomatic OSA occurs in 2–4% of adults and milder sleep apnea in up to 9% of adults [1].”
BackgroundYoung, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
The two‐period cross‐over clinical trial.
Hills, M., & Armitage, P. (1979) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1979.tb05903.x · Cited by 1,395 · cited 1×
“We examined treatment differences after adjustment for period effects, following the Hills–Armitage approach [22].”
MethodContinuous positive airways pressure for obstructive sleep apnoea in adults
Giles, T., Lasserson, T., Smith, B., White, J., Wright, J., & Cates, C. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001106.pub2 · Cited by 1,001
Kushida, C. A., Morgenthaler, T. I., Littner, M. R., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2006) · Sleep · doi:10.1093/sleep/29.2.240 · Cited by 749
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687 · cited 1×
“A recent review reports therapeutic success (defined as no more than ten apneas per hour of sleep) in an average of 52% of treated patients [12].”
BackgroundA Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514 · cited 3×
“Tongue retaining devices (TRDs) and mandibular repositioning appliances (MRAs) are the two categories of oral appliances used in treatment of SDB.”
BackgroundUnderdiagnosis of Sleep Apnea Syndrome in U.S. Communities
Kapur, V., Strohl, K. P., Redline, S., Iber, C., O'Connor, G., & Nieto, J. (2002) · Sleep And Breathing · doi:10.1055/s-2002-32318 · Cited by 475
Underdiagnosis of Sleep Apnea Syndrome in U.S. Communities
Kapur, V. K., Strohl, K. P., Redline, S. S., Iber, C., O’Connor, G. T., & Nieto, F. J. (2002) · Sleep And Breathing · doi:10.1007/s11325-002-0049-5 · Cited by 433
Cited by
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
Non-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Comparative Effects of Two Oral Appliances on Upper Airway Structure in Obstructive Sleep Apnea
Sutherland, K., Deane, S. A., Chan, A. S. L., Schwab, R. J., Ng, A., Darendeliler, M. A., & Cistulli, P. A. (2011) · SLEEP · doi:10.1093/sleep/34.4.469 · Cited by 119
Scherr, S. C., Dort, L. C., Almeida, F. R., Bennett, K. M., Blumenstock, N. T., Demko, B. G., Essick, G., Katz, S. G., McLornan, P. M., Phillips, K. S., et al. (2014) · Journal of Dental Sleep Medicine · doi:10.15331/jdsm.3738 · Cited by 97
Self-citationImpact of Obstructive Sleep Apnea and Its Treatments on Partners: A Literature Review
Luyster, F. S. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6504 · Cited by 102
“33 The short study time period of 1-w acclimatization followed by a 1-w washout could account for these results.”
Metadata
- Authors
- Dort, L., & Brant, R.
- Affiliations
- University of Calgary (CA)
- University of British Columbia (CA)
- Corresponding author
- Dort, Leslie
- ORCID
- Brant, Rollin
- Venue
- Sleep and Breathing
- Published
- 2008-05-07
- Volume
- 12
- Issue
- 4
- Pages
- 369-373
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2010712500
- Cited by
- 68
- References
- 31
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 4 · 2017: 4 · 2016: 16 · 2015: 4 · 2014: 14 · 2012: 4
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- sleep-disordered breathing, respiratory disturbance index, snoring, sleepiness, quality of life, sleep apnea treatment
- MeSH terms
- Adult, Airway Obstruction, Equipment Design, Female, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Patient Acceptance of Health Care, Suction, Tongue, Occlusal Splints, Cross-Over Studies, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A randomized, controlled, crossover study of a noncustomized tongue retaining device for sleep disordered breathing. https://app.cochat.ai/papers/10.1007/s11325-008-0187-5
- The paper
- Dort, L., & Brant, R. (2008). A randomized, controlled, crossover study of a noncustomized tongue retaining device for sleep disordered breathing. Sleep and Breathing. https://doi.org/10.1007/s11325-008-0187-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.