The DOI matches its Crossref record; 34 of the 36 references it cites were found in a registry or an index.
Insomnia symptoms influence CPAP compliance
Abstract
Purpose The aim of this study is to determine parameters which influence 6-month compliance of continuous positive airway pressure therapy (CPAP) in patients with obstructive sleep apnea syndrome (OSAS).Methods This prospective study investigated 73 patients (24 females) with OSAS and medical indication for CPAP therapy: age 55.1 ± 11.5 years, body mass index (BMI) 30.8 ± 5.0 kg/m2, Apnea-Hypopnea Index (AHI) 39.2 ± 26.7/h, Oxygen Desaturation Index (ODI) 33.2 ± 25.4/h, minimum O(2) saturation 78.9 ± 7.6%. The influence of baseline parameters (demographic and polysomnographic data, sleeping medication intakes, BMI, psychometrics [Epworth Sleepiness Scale, Regensburg Insomnia Scale, Vigilance test and Beck Depression Inventory]) on 6-month compliance was evaluated with a correlation and a linear regression analysis.Results The baseline value of the Regensburg Insomnia Scale (RIS) predicts 6-month CPAP compliance (r = -0.376, R (2) = 0.14, p < 0.001), although no other baseline parameter correlates. Patients with a compliance of <4 h/night show higher RIS scores, i.e., more insomnia symptoms (17.6 ± 8.8) compared to those with ≥4 h/night (12.6 ± 6.9; p < 0.05).Conclusions Insomnia symptoms prior to the beginning of CPAP treatment show a negative influence on CPAP compliance. Further studies should clarify, if a treatment of insomnia symptoms leads to a benefit in compliance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Importantly, recent research indicates that OSA patients with comorbid insomnia are less likely to accept and use CPAP therapy compared to OSA patients without insomnia [19][20][21][22][23][24].”
Citations
Cites
The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Beck, A. T., Steer, R. A., & Brown, G. (2011) · PsycTESTS Dataset · doi:10.1037/t00742-000 · Cited by 7,535 · cited 2×
“Beck Depression Inventory (BDI) second version [24] in German language [25]: A 21-item self-report inventory for measuring the severity of depression.”
MethodResultMarin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
International Classification of Sleep Disorders
Thorpy, M. (2017) · Sleep Disorders Medicine · doi:10.1007/978-1-4939-6578-6_27 · Cited by 2,505
Reliability and factor analysis of the Epworth Sleepiness Scale.
Johns, M. (1992) · Sleep · doi:10.1093/sleep/15.4.376 · Cited by 2,193
Sleep Apnea and Cardiovascular Disease
Somers, V. K., White, D. P., Amin, R. S., Abraham, W. T., Costa, F., Culebras, A., Daniels, S. R., Floras, J. S., Hunt, C. E., Olson, L. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.002 · Cited by 1,530
Weaver, T. E., Maislin, G., Dinges, D. F., Bloxham, T., George, C. F. P., Greenberg, H., Kader, G., Mahowald, M., Younger, J., & Pack, A. I. (2007) · Sleep · doi:10.1093/sleep/30.6.711 · Cited by 1,058
Kushida, C. A., Littner, M. R., Hirshkowitz, M., Morgenthaler, T. I., Alessi, C., Bailey, D. R., Boehlecke, B. A., Brown, T. M., Coleman, J., Friedman, L., et al. (2006) · SLEEP · doi:10.1093/sleep/29.3.375 · Cited by 784
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749 · cited 1×
“The titration procedure was performed similar to the clinical guidelines for manual titration of the American Academy of Sleep Medicine [21].”
MethodImproving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 482
S3-Leitlinie Nicht erholsamer Schlaf/Schlafstörungen
Riemann, D. W., Baum, E., Cohrs, S., Crönlein, T., Hajak, G., Hertenstein, E., Klose, P., Langhorst, J., Mayer, G., Nissen, C., et al. (2017) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-016-0097-x · Cited by 354
Self-citationPredictors of long-term compliance with continuous positive airway pressure
Kohler, M., Smith, D., Tippett, V., & Stradling, J. R. (2010) · Thorax · doi:10.1136/thx.2010.135848 · Cited by 275
Frequency of insomnia report in patients with obstructive sleep apnoea hypopnea syndrome (OSAHS)
Smith, S. S., Sullivan, K. A., Hopkins, W., & Douglas, J. A. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2004.03.005 · Cited by 188
Factors that influence CPAP adherence: an overview
Shapiro, G., & Shapiro, C. (2010) · Sleep and Breathing · doi:10.1007/s11325-010-0391-y · Cited by 172
Ballard, R. D., Gay, P. C., & Strollo, P. J. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27027 · Cited by 137
Improving Compliance with Nasal CPAP and Vigilance in Older Adults with OSAHS
Aloia, M. S., Dio, L. D., Ilniczky, N., Perlis, M. L., Greenblatt, D. W., & Giles, D. E. (2001) · Sleep And Breathing · doi:10.1007/s11325-001-0013-9 · Cited by 133
Broström, A., Nilsén, P., Johansson, P., Ulander, M., Strömberg, A., Svanborg, E., & Fridlund, B. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2009.04.010 · Cited by 125
Compliance with nasal CPAP in obstructive sleep apnea patients
Collard, P., Pieters, T., Aubert, G., Delguste, P., & Rodenstein, D. O. (1997) · Sleep Medicine Reviews · doi:10.1016/s1087-0792(97)90004-6 · Cited by 125
CPAP compliance: video education may help!
Wiese, H. J., Boethel, C. D., Phillips, B. A., Wilson, J. F., Peters, J. C., & Viggiano, T. (2005) · Sleep Medicine · doi:10.1016/j.sleep.2004.08.006 · Cited by 122
Improving Compliance with Nasal CPAP and Vigilance in Older Adults with OSAHS
Aloia, M. S., Dio, L. D., Ilniczky, N., Perlis, M. L., Greenblatt, D. W., & Giles, D. E. (2001) · Sleep And Breathing · doi:10.1055/s-2001-12789 · Cited by 117
Olsen, S., Smith, S. S., & Oei, T. P. S. (2008) · Clinical Psychology Review · doi:10.1016/j.cpr.2008.07.004 · Cited by 104
CPAP compliance in patients with obstructive sleep apnea syndrome
Yetkin, O., Kunter, E., & Gunen, H. (2008) · Sleep And Breathing · doi:10.1007/s11325-008-0188-4 · Cited by 102
Psychological Status, Syndromatic Measures, and Compliance with Nasal CPAP Therapy for Sleep Apnea
Edinger, J. D., Carwile, S. T., Miller, P. P., Hope, V. T., & Mayti, C. (1994) · Perceptual and Motor Skills · doi:10.2466/pms.1994.78.3c.1116 · Cited by 91
Poulet, C., Veale, D., Arnol, N., Levy, P. A., Pépin, J., & Tyrrell, J. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2009.01.007 · Cited by 89
Social-cognitive correlates of CPAP adherence in experienced users
Stepnowsky, C. J., Marler, M., Palau, J. J., & Brooks, J. A. (2006) · Sleep Medicine · doi:10.1016/j.sleep.2005.11.004 · Cited by 77
Nguyên, X.-L., Chaskalovic, J., Rakotonanahary, D., & Fleury, B. (2010) · Sleep Medicine · doi:10.1016/j.sleep.2010.04.008 · Cited by 69
(2009) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-009-0430-8 · Cited by 52
CPAP Compliance in Sleep Apnea Patients with and without Laboratory CPAP Titration
Means, M. K., Edinger, J. D., & Husain, A. M. (2004) · Sleep And Breathing · doi:10.1007/s11325-004-0007-5 · Cited by 50
Predictors of continuous positive airway pressure adherence
CATCHESIDE, P. G. (2010) · F1000 Medicine Reports · doi:10.3410/m2-70 · Cited by 49
Sopkova, Z., Dorková, Z., & Tkáčová, R. (2009) · Wiener klinische Wochenschrift · doi:10.1007/s00508-009-1181-z · Cited by 46
Alves, C., Caminha, J. M. P. C., da Silva, A. M., & Mendonça, D. M. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0542-9 · Cited by 34
Die Kontrollüberzeugung ist ein Prädiktor für CPAP-Compliance bei obstruktivem Schlafapnoesyndrom
de Zeeuw, J., Baberg, H. T., Duchna, H., Kempkens, D., Walther, J., Schultze‐Werninghaus, G., Rasche, K., & Orth, M. (2007) · Pneumologie · doi:10.1055/s-2007-959162 · Cited by 16
Langzeit-Compliance der CPAP-Therapie - aktueller Stand, Prädiktoren und Interventionsmöglichkeiten
Orth, M., Kotterba, S., Walther, J., Rasche, K., Schultze‐Werninghaus, G., & Duchna, H. W. (2006) · Pneumologie · doi:10.1055/s-2006-944234 · Cited by 7
Flagged first, then by citations
2 of the 36 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Hautzinger M, Keller F, Kühner C (2006) Das Beck Depressionsinventar II. Deutsche Bearbeitung und Handbuch zum BDI II. Harcourt Test Services, Frankfurt
Cited by
Sorted by citations
Predictors of Continuous Positive Airway Pressure Adherence in Patients with Obstructive Sleep Apnea
Mehrtash, M., Bakker, J. P., & Ayas, N. (2019) · Lung · doi:10.1007/s00408-018-00193-1 · Cited by 231
Bi-directional relationships between co-morbid insomnia and sleep apnea (COMISA)
Sweetman, A., Lack, L., McEvoy, R. D., Smith, S., Eckert, D. J., Osman, A., Carberry, J. C., Wallace, D., Nguyen, P. D., & Catcheside, P. (2021) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2021.101519 · Cited by 203
Developing a successful treatment for co-morbid insomnia and sleep apnoea
Sweetman, A. M., Lack, L. C., Catcheside, P. G., Antic, N. A., Chai-Coetzer, C. L., Smith, S. S., Douglas, J. A., & McEvoy, R. D. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.04.004 · Cited by 185
Karimi, M., Hedner, J. A., Häbel, H., Nerman, O., & Grote, L. (2015) · SLEEP · doi:10.5665/sleep.4486 · Cited by 176
Björnsdóttir, E., Janson, C., Sigurdsson, J. F., Gehrman, P., Perlis, M., Juliusson, S., Arnardottir, E. S., Kuna, S. T., Pack, A. I., Gislason, T., et al. (2013) · Sleep · doi:10.5665/sleep.3226 · Cited by 174
Metadata
- Authors
- Pieh, C., Bach, M., Popp, R., Jara, C., Crönlein, T., Hajak, G., & Geisler, P.
- Affiliations
- University Hospital Regensburg (DE)
- Corresponding author
- Pieh, Christoph
- Venue
- Sleep And Breathing
- Published
- 2012-02-04
- Volume
- 17
- Issue
- 1
- Pages
- 99-104
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W1980731633
- Cited by
- 107
- References
- 36
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 13 · 2021: 6 · 2020: 7 · 2019: 7 · 2018: 7 · 2017: 9 · 2016: 3 · 2015: 5 · 2014: 6 · 2013: 6 · 2012: 2
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Sleep And Breathing (publishedVersion)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Keywords
- CPAP adherence, insomnia symptoms, obstructive sleep apnea
- MeSH terms
- Adult, Female, Follow-Up Studies, Germany, Humans, Sleep Initiation and Maintenance Disorders, Male, Middle Aged, Patient Compliance, Prospective Studies, Statistics as Topic, Utilization Review, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review