Durability of treatment effects of the Sleep Position Trainer versus oral appliance therapy in positional OSA: 12-month follow-up of a randomized controlled trial
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: The Sleep Position Trainer (SPT) is a new option for treating patients with positional obstructive sleep apnea (POSA). This study investigated long-term efficacy, adherence, and quality of life during use of the SPT device compared with oral appliance therapy (OAT) in patients with POSA. METHODS: This prospective, multicenter trial randomized patients with mild to moderate POSA (apnea-hypopnea index [AHI] 5-30/h) to SPT or OAT. Polysomnography was performed at baseline and after 3 and 12 months' follow-up. The primary endpoint was OSA severity; adherence, quality of life, and adverse events were also assessed. RESULTS: Ninety-nine patients were randomized and 58 completed the study (29 in each group). Median AHI in the SPT group decreased from 13.2/h at baseline to 7.1/h after 12 months (P < 0.001); corresponding values in the OAT group were 13.4/h and 5.0/h (P < 0.001), with no significant between-group difference (P = 1.000). Improvements throughout the study were maintained at 12 months. Long-term median adherence was also similar in the two treatment groups; the proportion of patients who used their device for ≥ 4 h for 5 days in a week was 100% in the SPT group and 97.0% in the OAT group (P = 0.598). CONCLUSIONS: The efficacy of SPT therapy was maintained over 12 months and was comparable to that of OAT in patients with mild to moderate POSA. Adherence was relatively high, and similar in the two groups. TRIAL REGISTRATION: www.clinicaltrials.gov (NCT02045576).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of obstructive sleep apnea in the general population: A systematic review
Senaratna, C. V., Perret, J. L., Lodge, C. J., Lowe, A. J., Campbell, B. E., Matheson, M. C., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2016.07.002 · Cited by 2,581
Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study
Heinzer, R., Vat, S., Marques-Vidal, P., Marti-Soler, H., Andries, D., Tobback, N., Mooser, V, Preisig, M., Malhotra, A., Waeber, G., et al. (2015) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(15)00043-0 · Cited by 2,481 · cited 1×
“The proportion of men and women with an apneahypopnea index (AHI) of > 5/h on polysomnography (PSG) was 84 and 61%, respectively [2].”
BackgroundAdherence to Continuous Positive Airway Pressure Therapy: The Challenge to Effective Treatment
Weaver, T. E., & Grunstein, R. R. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-119mg · Cited by 1,680 · cited 2×
“CPAP is the gold standard therapy for moderate to severe OSA, but adherence to CPAP is often suboptimal, necessitating exploration of other options [12].”
BackgroundStrollo, P. J., & Rogers, R. M. (1996) · New England Journal of Medicine · doi:10.1056/nejm199601113340207 · Cited by 1,313
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299
Sawyer, A. M., Gooneratne, N. S., Marcus, C. L., Ofer, D., Richards, K. C., & Weaver, T. E. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.01.003 · Cited by 900
Caples, S. M., Rowley, J. A., Prinsell, J. R., Pallanch, J. F., Elamin, M. B., Katz, S. G., & Harwick, J. D. (2010) · Sleep · doi:10.1093/sleep/33.10.1396 · Cited by 541
Positional vs Nonpositional Obstructive Sleep Apnea Patients
Oksenberg, A., Arons, E., Radwan, H., & Silverberg, D. S. (1997) · Chest · doi:10.1378/chest.112.3.629 · Cited by 441
Maxillomandibular Advancement for Treatment of Obstructive Sleep Apnea: A Meta-analysis
Zaghi, S., Holty, J.-E. C., Certal, V., Abdullatif, J., Guilleminault, C., Powell, N. B., Riley, R. W., & Camacho, M. (2016) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2015.2678 · Cited by 355
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Positional Therapy for Positional Obstructive Sleep Apnea
Yingjuan, M., Siang, W. H., Leong Alvin, T. K., & Poh, H. P. (2019) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2018.10.003 · Cited by 28
Standardized framework to report on the role of sleeping position in sleep apnea patients
Ravesloot, M. J. L., Vonk, P. E., Maurer, J. T., Oksenberg, A., & de Vries, N. (2021) · Sleep and Breathing · doi:10.1007/s11325-020-02255-2 · Cited by 22
Metadata
- Authors
- de Ruiter, M. H. T., Benoist, L. B. L., de Vries, N., & de Lange, J.
- Venue
- Sleep and Breathing
- Published
- 2017-09-15
- Volume
- 22
- Issue
- 2
- Pages
- 441-450
- ISSN
- 1520-9512 (ISSN-L)
- 1522-1709
- OpenAlex
- W2754331151
- Cited by
- 59
- References
- 9
- FWCI
- 4.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.