Gait analysis in children with cerebral palsy via inertial and magnetic sensors
Open accessThe DOI matches its Crossref record.
Abstract
3D kinematic measurements in children with cerebral palsy (CP) to assess gait deviations can only be performed in gait laboratories using optoelectronic systems. Alternatively, an inertial and magnetic measurement system (IMMS) can be applied for ambulatory motion-tracking. A protocol named Outwalk has recently been developed to measure the 3D kinematics during gait with IMMS. This study preliminary validated the application of IMMS, based on the Outwalk protocol, in gait analysis of six children with CP and one typically developing child. Reference joint kinematics were simultaneously obtained from a laboratory-based system and protocol. On average, the root mean square error (RMSE) of Outwalk/IMMS, compared to the reference, was less than 17° in the transversal plane, and less than 10° in the sagittal and frontal planes. The greatest differences were found in offsets in the knee and ankle rotation, and in the hip flexion. These offset differences were mainly caused by a different anatomical calibration in the protocols. When removing the offsets, RMSE was always less than 4°. Therefore, IMMS is suitable for gait analysis of major joint angles in a laboratory-free setting. Further studies should focus on improvement of anatomical calibrations of IMMS that can be performed in children with CP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
Wearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Bolink, S. A. A. N., Naisas, H., Senden, R., Essers, H., Heyligers, I. C., Meijer, K., & Grimm, B. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.11.009 · Cited by 147
“[5] evaluated 3D inematic measurements of the hip, knee and ankle joints in chilren with cerebral palsy (CP), with optical MOCAP markers attached nto the IMUs, and found a RMSE in the range of [4.”
Background
Metadata
- Authors
- van den Noort, J. C., Ferrari, A., Cutti, A. G., Becher, J. G., & Harlaar, J.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2012-12-09
- Volume
- 51
- Issue
- 4
- Pages
- 377-386
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1994581337
- Cited by
- 93
- References
- 0
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gait analysis in children with cerebral palsy via inertial and magnetic sensors. https://app.cochat.ai/papers/10.1007/s11517-012-1006-5
- The paper
- van den Noort, J. C., Ferrari, A., Cutti, A. G., Becher, J. G., & Harlaar, J. (2013). Gait analysis in children with cerebral palsy via inertial and magnetic sensors. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-012-1006-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.