The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Drowsiness detection using heart rate variability
Abstract
It is estimated that 10-30 % of road fatalities are related to drowsy driving. Driver's drowsiness detection based on biological and vehicle signals is being studied in preventive car safety. Autonomous nervous system activity, which can be measured noninvasively from the heart rate variability (HRV) signal obtained from surface electrocardiogram, presents alterations during stress, extreme fatigue and drowsiness episodes. We hypothesized that these alterations manifest on HRV and thus could be used to detect driver's drowsiness. We analyzed three driving databases in which drivers presented different sleep-deprivation levels, and in which each driving minute was annotated as drowsy or awake. We developed two different drowsiness detectors based on HRV. While the drowsiness episodes detector assessed each minute of driving as "awake" or "drowsy" with seven HRV derived features (positive predictive value 0.96, sensitivity 0.59, specificity 0.98 on 3475 min of driving), the sleep-deprivation detector discerned if a driver was suitable for driving or not, at driving onset, as function of his sleep-deprivation state. Sleep-deprivation state was estimated from the first three minutes of driving using only one HRV feature (positive predictive value 0.80, sensitivity 0.62, specificity 0.88 on 30 drivers). Incorporating drowsiness assessment based on HRV signal may add significant improvements to existing car safety systems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Whether it is subjective scale (40), heart rate variability analysis (41, 42), or electroencephalograph (EEG) analysis (43), SD increased fatigue and sleepiness.”
From Sleep deprivation alters utilization of negative feedback in risky decision-making (2024) · cites this paper as [42]
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Heart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820
Research works printed but not linked: 23
- Baharav A, Kotagal S, Gibbons V, Rubin BK, Pratt G, Karin J, Akselrod S (1995) Fluctuations in autonomic nervous activity during sleep displayed by power spectrum analysis of heart rate variability. Neurology 45(6):1183–1187 · DOI
- Bailón R, Laouini G, Grao C, Orini M, Laguna P, Meste O (2011) The integral pulse frequency modulation model with time-varying threshold: Application to heart rate variability analysis during exercise stress testing. IEEE Trans Biomed Eng 58(3):642–652 · DOI
- Bailón R, Mainardi L, Orini M, Sörnmo L, Laguna P (2010) Analysis of heart rate variability during exercise stress testing using respiratory information. Biomed Signal Process Control 5(4):299–310 · DOI
- Drake C, Roehrs T, Breslau N, Johnson E, Jefferson C, Scofield H, Roth T (2010) The 10-year risk of verified motor vehicle crashes in relation to physiologic sleepiness. Sleep 33(6):745 · DOI
- Furman G, Baharav A, Cahan C, Akselrod S (2008) Early detection of falling asleep at the wheel: a heart rate variability approach. Comput Cardiol, pp 1109–112 · DOI
- Gunzelmann G, Gross JB, Gluck KA, Dinges DF (2009) Sleep deprivation and sustained attention performance: integrating mathematical and cognitive modeling. Cogn Sci 33(5):880–910 · DOI
- Lachenbruch PA, Goldstein M (1979) Discriminant analysis. Biometrics 35(1): 69–85. http://www.jstor.org/stable/2529937 · DOI
- Li G, Chung WY (2013) Detection of driver drowsiness using wavelet analysis of heart rate variability and a support vector machine classifier. Sensors 13(12):16494–16511 · DOI
- Martínez JP, Almeida R, Olmos S, Rocha AP, Laguna P (2004) A wavelet-based ecg delineator: evaluation on standard databases. IEEE Trans Biomed Eng 51(4):570–581 · DOI
- Mateo J, Laguna P (2003) Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal. IEEE Trans Biomed Eng 50(3):334–343 · DOI
- Michail E, Kokonozi A, Chouvarda I, Maglaveras N (2008) Eeg and hrv markers of sleepiness and loss of control during car driving. In: Conf Proc IEEE Eng Med Biol Soc, pp 2566 –2569 · DOI
- Paik H (2000) Comments on neural networks. Sociol Methods Res 28(4):425–453. doi: 10.1177/0049124100028004002 . http://smr.sagepub.com/content/28/4/425.abstract · DOI
- Patel M, Lal S, Kavanagh D, Rossiter P (2011) Applying neural network analysis on heart rate variability data to assess driver fatigue. Expert Syst Appl 38(6):7235–7242 · DOI
- Philip P, Akerstedt T (2006) Transport and industrial safety, how are they affected by sleepiness and sleep restriction? Sleep Med Rev 10(5):347–356 · DOI
- Ripley BD (2007) Linear discriminant analysis. Pattern recognition and neural networks. Cambridge University Press, Cambridge, pp 91–120
- Rodríguez-Ibáñez N, García-González M, Fernández-Chimeno M, Ramos-Castro J (2011) Drowsiness detection by thoracic effort signal analysis in real driving environments. In: Conf Proc IEEE Eng Med Biol Soc · DOI
- Shinar Z, Akselrod S, Dagan Y, Baharav A (2006) Autonomic changes during wake-sleep transition: a heart rate variability based approach. Auton Neurosci 130:17–27 · DOI
- Strohl K (2012) Assessments of driving risk in sleep apnea., Respiratory medicineHumana Press, USA
- Task Force of ESC and NASPE (1996) Heart rate variability : standards of measurement, physiological interpretation, and clinical use. Circulation 93(5):1043–1065 · DOI · Paper page
- Valenza G, Citi L, Barbieri R (2014) Estimation of instantaneous complex dynamics through lyapunov exponents: A study on heartbeat dynamics. PLoS One 9(8):e105,622. doi: 10.1371/journal.pone.0105622 · DOI
- Verster JC, Taillard J, Sagaspe P, Olivier B, Philip P (2011) Prolonged nocturnal driving can be as dangerous as severe alcohol-impaired driving. J Sleep Res 20(4):585–588 · DOI
- Wessel N, Voss A, Malberg H, Ziehmann C, Voss HU, Schirdewan A, Meyerfeldt U, Kurths J (2000) Nonlinear analysis of complex phenomena in cardiological data. Herzschrittmachertherapie und Elektrophysiologie 11(3):159–173 · DOI
- Yang G, Lin Y, Bhattacharya P (2010) A driver fatigue recognition model based on information fusion and dynamic bayesian network. Inf Sci (Ny) 180(10):1942–1954 · DOI
Cited by
Sorted by citations
Spectral Analysis of Heart Rate Variability: Time Window Matters
Li, K., Rüdiger, H., & Ziemssen, T. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00545 · Cited by 215
Sleep deprivation alters utilization of negative feedback in risky decision-making
Xu, W., Wang, L., Yang, L., Zhu, Y., & Chen, P. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1307408 · Cited by 2
Metadata
- Authors
- Vicente, J., Laguna, P., Bartra, A., & Bailón, R.
- ORCID
- Vicente, José
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-01-16
- Volume
- 54
- Issue
- 6
- Pages
- 927-937
- ISSN
- 0140-0118
- 1741-0444
- Cited by
- 255
- References
- 2
- Language
- en
- Licence
- www.springer.com/tdm (tdm)
- Funders
- Ministerio de Ciencia e Innovación (TIN2014-53567-R, TEC2013-42140-R, TRA2009-0127, UZ2014-TEC-01)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drowsiness detection using heart rate variability. https://app.cochat.ai/papers/10.1007/s11517-015-1448-7
- The paper
- Vicente, J., Laguna, P., Bartra, A., & Bailón, R. (2016). Drowsiness detection using heart rate variability. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-015-1448-7