Dual fluoroscopic imaging and CT-based finite element modelling to estimate forces and stresses of grafts in anatomical single-bundle ACL reconstruction with different femoral tunnels

Open access
Xiao, Yang, Ling, Ming, Liang, Zhenming, Ding, Jian, Zhan, Shi, Hu, Hai, Chen, Bin · 2021 · International Journal of Computer Assisted Radiology and Surgery

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index; 3 of the 36 sources its claims cite were checked for support.

Abstract

PURPOSE: Little is known about the in vivo forces and stresses on grafts used in anterior cruciate ligament (ACL) reconstruction. The aims of this study were to evaluate and compare the forces and stresses on grafts used in anatomical single-bundle ACL reconstruction at different locations of the femoral footprint (anterior vs middle vs posterior; high vs middle vs low) during a lunge motion. METHODS: Establish subject-specific finite element models with different graft's tunnel loci to represent the primary ACL reconstructions. A displacement controlled finite element method was used to simulate lunge motions (full extension to ~ 100° of flexion) with six-degree-of-freedom knee kinematics data obtained from the validated dual fluoroscopic imaging techniques. The reaction force of the femur and maximal principal stresses of the grafts were subsequently calculated during knee flexion. RESULTS: Increased and decreased graft forces were observed when the grafts were located higher and lower on the femoral footprint, respectively; anterior and posterior graft placement did not significantly affect the graft force. Lower and posterior graft placement resulted in less stress on the graft at higher degrees of flexion; there were no significant differences in stress when the grafts were placed from 0° to 30° of flexion on the femoral footprint. CONCLUSION: The proposed method is able to simulate knee joint motion based on in vivo kinematics. The results demonstrate that posterior to the centre of the femoral footprint is the strategic location for graft placement, and this placement results in anatomical graft behaviour with a low stress state.

Overview

CoChat Summary

TL;DR

This single-subject study combined dual fluoroscopic imaging with CT-based finite element modeling to test how femoral tunnel placement affects ACL graft force and stress during a lunge. It found that placing the graft posterior to the center of the femoral footprint produced more anatomical behavior and lower stress, especially at higher flexion angles.

Key findings

  • A single healthy male volunteer was modeled; the lunge simulation covered full extension to about 100° of flexion.
  • Graft force peaked at approximately 30° of flexion, then decreased; force was significantly affected by higher–lower tunnel location (P < 0.001) but not anterior–posterior location (P = 0.971).
  • Maximal principal graft stress did not change significantly before 30° of flexion, then rose and fell after a peak at 90° of flexion; stress differed by higher–lower location (P < 0.001) and by anterior vs posterior location (P = 0.037), but not by anterior–posterior location overall (P = 0.104).
  • The low and posterior tunnel locations produced lower stress; the authors conclude that posterior to the center of the femoral footprint is the strategic graft placement location.

Methods

  • Subject-specific finite element models were built for ACL reconstruction at 21 femoral attachment points spanning anterior/middle/posterior and high/middle/low locations; the tibial attachment was fixed at the midpoint of the tibial ACL footprint.
  • One healthy 26-year-old male underwent CT scanning and dual fluoroscopic imaging during a lunge from full extension to ~100° flexion; 6DOF knee kinematics from the fluoroscopy were applied to the FE models.
  • The simulation used displacement-controlled finite element analysis in Abaqus with an initial graft tension of 80 N; reaction force and maximal principal stress were computed, and differences were tested with repeated-measures ANOVA plus Kruskal–Wallis/Mann–Whitney U tests.

Limitations

  • The paper states that the full range of motion was not studied: hyperextension and flexion beyond 100° were not analyzed; only lunge activity was tested; other activities such as walking and stair ascent were not considered.
  • The study used data from a single subject, so the authors state the procedure should be repeated in other subjects to see whether the result generalizes.
  • Evident from the text: the models were simulation-based rather than direct in vivo force/stress measurements, so the conclusions depend on modeling assumptions (for example, graft material properties and boundary conditions).

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s11548-021-02307-2

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 a Dual fluoroscopy was used to record the motion of the subject's right knee while he performed a lunge motion. b CT imaging was used to create 3D models of both the femur and tibia. c The 3D models were synchronized with the dual fluoroscopic images to reproduce the motion of the subject's knee during the movements
Fig. 1 a Dual fluoroscopy was used to record the motion of the subject's right knee while he performed a lunge motion. b CT imaging was used to create 3D models of both the femur and tibia. c The 3D models were synchronized with the dual fluoroscopic images to reproduce the motion of the subject's knee during the movementsCC BY · PubMed Central
Fig. 2 a Definitions of the local femoral and tibial coordinate systems. b Definitions of the Euler angles and 3D translation. A reference point of the femur; B reference point of the tibia. Three angular rotations and a 3D translation steps were performed with finite element analysis
Fig. 2 a Definitions of the local femoral and tibial coordinate systems. b Definitions of the Euler angles and 3D translation. A reference point of the femur; B reference point of the tibia. Three angular rotations and a 3D translation steps were performed with finite element analysisCC BY · PubMed Central
Fig. 3 Screenshots of the alignment and the output of the results. a Projections of the models of each frame were matched. b 6DOF changes in the process of knee motion (ten points correspond to ten flexion angles from 10° to 100°)
Fig. 3 Screenshots of the alignment and the output of the results. a Projections of the models of each frame were matched. b 6DOF changes in the process of knee motion (ten points correspond to ten flexion angles from 10° to 100°)CC BY · PubMed Central
Fig. 4 a The twenty-one femoral attachment points of the ACL on the femoral footprint. a Lateral intercondylar ridge; b the edge of femoral articular cartilage. b, c The different locations. A anterior location; M middle location; P posterior location. H high location; M middle location; L low location. d The tibial attachment point of the ACL that was identified based on the bony landmarks on the 3D CT models. PL posterolateral; AM anteromedial; c anterior ridge; d medial intercondylar ridge
Fig. 4 a The twenty-one femoral attachment points of the ACL on the femoral footprint. a Lateral intercondylar ridge; b the edge of femoral articular cartilage. b, c The different locations. A anterior location; M middle location; P posterior location. H high location; M middle location; L low location. d The tibial attachment point of the ACL that was identified based on the bony landmarks on the 3D CT models. PL posterolateral; AM anteromedial; c anterior ridge; d medial intercondylar ridgeCC BY · PubMed Central
Fig. 5 a Anterior view of the model at 20° of flexion. b Lateral view of the model at 20° of flexion
Fig. 5 a Anterior view of the model at 20° of flexion. b Lateral view of the model at 20° of flexionCC BY · PubMed Central
Fig. 6 An example of the finite element analysis process with graft placement on the centre of the footprint is shown from a – e. a The model at 20° of knee flexion is shown after an initial graft tension of 80 N was applied. b, c The models at the initial and final positions (0° and 100°) are shown as examples. d The reaction force of the femur was calculated for each model during the entire range of motion. e The maximal principal stress on the graft was near the femoral tunnel
Fig. 6 An example of the finite element analysis process with graft placement on the centre of the footprint is shown from a – e. a The model at 20° of knee flexion is shown after an initial graft tension of 80 N was applied. b, c The models at the initial and final positions (0° and 100°) are shown as examples. d The reaction force of the femur was calculated for each model during the entire range of motion. e The maximal principal stress on the graft was near the femoral tunnelCC BY · PubMed Central
Fig. 7 The data were compared in both the higher–lower and anterior–posterior directions. a, b Comparison of the reaction force at the different locations during the entire range of motion. c, d Comparison of the maximal principal stress at the different locations during the entire range of motion. All values are presented as the mean and standard deviation
Fig. 7 The data were compared in both the higher–lower and anterior–posterior directions. a, b Comparison of the reaction force at the different locations during the entire range of motion. c, d Comparison of the maximal principal stress at the different locations during the entire range of motion. All values are presented as the mean and standard deviationCC BY · PubMed Central

Verification

Claims the paper makes

3 Valid · 1 Not valid · 20 Not checked · 31 Own results and interpretations

16 more claims

Create a free account to see all 55 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 21
  • Probably not a substantial claim. 25

Create a free account to see these claims.

Citations

Cites

Show all 35 references

Cited by

See all 14

Metadata

Authors
Xiao, Y., Ling, M., Liang, Z., Ding, J., Zhan, S., Hu, H., & Chen, B.
Affiliations
  • Nanfang Hospital (CN)
  • Shanghai Medical College of Fudan University (CN)
  • Shanghai Jiao Tong University (CN)
Corresponding author
  • Hu, Hai
  • Chen, Bin
Venue
International Journal of Computer Assisted Radiology and Surgery
Published
2021-01-20
Volume
16
Issue
3
Pages
495-504
ISSN
  • 1861-6410 (ISSN-L)
  • 1861-6429
OpenAlex
W3122638609
Cited by
14
References
35
Citations by year
2026: 1 · 2025: 3 · 2024: 3 · 2023: 2 · 2022: 5
FWCI
2.35
Type
journal article
Language
en
Open access
Licence
Locations
  • International Journal of Computer Assisted Radiology and Surgery (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
Keywords
anterior cruciate ligament reconstruction, femoral footprint, knee kinematics
MeSH terms
Adult, Biomechanical Phenomena, Cadaver, Femur, Fluoroscopy, Humans, Knee Joint, Male, Motion, Stress, Mechanical, Tibia, Tomography, X-Ray Computed, Range of Motion, Articular, Finite Element Analysis, Anterior Cruciate Ligament Reconstruction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual fluoroscopic imaging and CT-based finite element modelling to estimate forces and stresses of grafts in anatomical single-bundle ACL reconstruction with different femoral tunnels. https://app.cochat.ai/papers/10.1007/s11548-021-02307-2
The paper
Xiao, Y., Ling, M., Liang, Z., Ding, J., Zhan, S., Hu, H., & Chen, B. (2021). Dual fluoroscopic imaging and CT-based finite element modelling to estimate forces and stresses of grafts in anatomical single-bundle ACL reconstruction with different femoral tunnels. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-021-02307-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.