CoChat

Surgical Outcomes After Gastric Electric Stimulator Placement for Refractory Gastroparesis

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Background Gastric electric stimulation (GES) is used for refractory gastroparesis symptoms. Although symptomatic improvement has been reported with GES, few studies describe the need for additional surgery after placement. Our goal was to evaluate the outcomes of a large series of GES at a single institution.Methods A retrospective review was performed for patients undergoing Enterra GES (Medtronic, Inc.) placement for refractory gastroparesis from October 2000 to October 2011. The main outcome measures were the need/indications for additional procedures and symptom improvement.Results A total of 266 patients had a GES implanted; 233 had complete records and were included in the analysis. Fifty-eight percent (n = 135) required an additional procedure after GES placement. Nutrition access (45 patients requiring 77 procedures) and subcutaneous pocket issues (n = 21) were the most common indications for subsequent procedures. Twelve percent (n = 29) had the GES explanted, mainly for continued gastroparetic symptoms (n = 11), mechanical issues (n = 9), or infection (n = 4). Ninety patients had subsequent hospitalizations, mainly for gastroparetic flares. Mortality during the follow-up period was 2.1 %. BMI was predictive of additional surgical procedure: when overweight, the risk of pocket revision increased 4.45 times (OR = 4.452). Of 74 most recent patients with prospective long-term outcome data, 70 % reported improved symptoms of pain, bloating, and nausea.Conclusions Although most patients reported symptomatic improvement after GES implantation, there is often a need for additional surgical procedures as well as associated complications after GES placement. Additional procedures were most frequent for surgical nutrition and subcutaneous pocket issues; pocket revisions were more frequent in obese patients. From our results, we amended our practice to add a jejunostomy tube in malnourished patients and suture the stimulator to the subcutaneous pocket fascia. Further studies will determine if these changes reduce the rate of complications and additional procedures after GES placement.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11605-013-2147-z

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 28

Metadata

Authors
Keller, D. S., Parkman, H. P., Boucek, D. O., Sankineni, A., Meilahn, J. E., Gaughan, J. P., & Harbison, S.
Affiliations
Temple University (US)
Corresponding author
Parkman, Henry P.
Venue
Journal of Gastrointestinal Surgery
Publisher
Elsevier BV
Published
2013-04
Volume
17
Issue
4
Pages
620-626
ISSN
1091-255X (ISSN-L)
OpenAlex
W2170662323
Cited by
27
References
15
Citations by year
2024: 4 · 2023: 2 · 2021: 1 · 2020: 6 · 2019: 4 · 2018: 1 · 2016: 2 · 2015: 3 · 2014: 2 · 2013: 1
FWCI
2.51
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Journal of Gastrointestinal Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal motility and disorders
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal Bleeding Diagnosis and Treatment
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
gastric electrical stimulation, refractory gastroparesis, additional surgical procedures, obesity, body mass index, jejunostomy tube, device explantation, symptom improvement
MeSH terms
Adolescent, Adult, Aged, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Retrospective Studies, Treatment Outcome, Gastroparesis, Young Adult, Implantable Neurostimulators

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surgical Outcomes After Gastric Electric Stimulator Placement for Refractory Gastroparesis. https://app.cochat.ai/papers/10.1007/s11605-013-2147-z
The paper
Keller, D. S., Parkman, H. P., Boucek, D. O., Sankineni, A., Meilahn, J. E., Gaughan, J. P., & Harbison, S. (2013). Surgical Outcomes After Gastric Electric Stimulator Placement for Refractory Gastroparesis. Journal of Gastrointestinal Surgery. https://doi.org/10.1007/s11605-013-2147-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.