CoChat

Differential Diagnosis Generators: an Evaluation of Currently Available Computer Programs

Open access
Bond, William F., Schwartz, Linda M., Weaver, Kevin R., Levick, Donald, Giuliano, Michael, Graber, Mark L. · 2012 · Journal of General Internal Medicine
Cited by 132

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Differential diagnosis (DDX) generators are computer programs that generate a DDX based on various clinical data. OBJECTIVE: We identified evaluation criteria through consensus, applied these criteria to describe the features of DDX generators, and tested performance using cases from the New England Journal of Medicine (NEJM©) and the Medical Knowledge Self Assessment Program (MKSAP©). METHODS: We first identified evaluation criteria by consensus. Then we performed Google® and Pubmed searches to identify DDX generators. To be included, DDX generators had to do the following: generate a list of potential diagnoses rather than text or article references; rank or indicate critical diagnoses that need to be considered or eliminated; accept at least two signs, symptoms or disease characteristics; provide the ability to compare the clinical presentations of diagnoses; and provide diagnoses in general medicine. The evaluation criteria were then applied to the included DDX generators. Lastly, the performance of the DDX generators was tested with findings from 20 test cases. Each case performance was scored one through five, with a score of five indicating presence of the exact diagnosis. Mean scores and confidence intervals were calculated. KEY RESULTS: Twenty three programs were initially identified and four met the inclusion criteria. These four programs were evaluated using the consensus criteria, which included the following: input method; mobile access; filtering and refinement; lab values, medications, and geography as diagnostic factors; evidence based medicine (EBM) content; references; and drug information content source. The mean scores (95% Confidence Interval) from performance testing on a five-point scale were Isabel© 3.45 (2.53, 4.37), DxPlain® 3.45 (2.63-4.27), Diagnosis Pro® 2.65 (1.75-3.55) and PEPID™ 1.70 (0.71-2.69). The number of exact matches paralleled the mean score finding. CONCLUSIONS: Consensus criteria for DDX generator evaluation were developed. Application of these criteria as well as performance testing supports the use of DxPlain® and Isabel© over the other currently available DDX generators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11606-011-1804-8

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 132

Metadata

Authors
Bond, W. F., Schwartz, L. M., Weaver, K. R., Levick, D., Giuliano, M., & Graber, M. L.
Venue
Journal of General Internal Medicine
Published
2011-07-26
Volume
27
Issue
2
Pages
213-219
ISSN
  • 0884-8734 (ISSN-L)
  • 1525-1497
OpenAlex
W2013473976
Cited by
132
References
3
FWCI
6.78
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Differential Diagnosis Generators: an Evaluation of Currently Available Computer Programs. https://app.cochat.ai/papers/10.1007/s11606-011-1804-8
The paper
Bond, W. F., Schwartz, L. M., Weaver, K. R., Levick, D., Giuliano, M., & Graber, M. L. (2012). Differential Diagnosis Generators: an Evaluation of Currently Available Computer Programs. Journal of General Internal Medicine. https://doi.org/10.1007/s11606-011-1804-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.