A Survey on Fault Diagnosis and Fault Tolerant Methodologies for Permanent Magnet Synchronous Machines
The DOI matches its Crossref record; 146 of the 146 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Nevertheless, it is also the weak link where different faults occur frequently [19], [22], [23].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [22]
In the citing paper
“It concerned also PMSM drives and examples of such control concepts can be found in [22], [23].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [22]
In the citing paper
“The open-switch fault may result in current distortion, abnormal load operation, overheating, decreased efficiency and the motor output irresistible torque gap, resulting in large torque ripple or even braking torque [22], [251].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [22]
Citations
Cites
Kennedy, J., & Eberhart, R. (2002) · Proceedings of ICNN'95 - International Conference on Neural Networks · doi:10.1109/icnn.1995.488968 · Cited by 58,192
Classification and Regression by randomForest
Liaw, A. I., & Wiener, M. C. (2007) · Cited by 18,594
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
Diagnosis and Fault-Tolerant Control
Blanke, M., Kinnaert, M., Lunze, J., & Staroswiecki, M. (2003) · Springer eBooks · doi:10.1007/978-3-662-05344-7 · Cited by 2,789
Bibliographical review on reconfigurable fault-tolerant control systems
Zhang, Y., & Jiang, J. (2008) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2008.03.008 · Cited by 2,652
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Artificial intelligence for fault diagnosis of rotating machinery: A review
Liu, R., Yang, B., Zio, E., & Chen, X. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.02.016 · Cited by 2,188
Overview of Permanent-Magnet Brushless Drives for Electric and Hybrid Electric Vehicles
Chau, K. T., Chan, C. C., & Liu, C. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.918403 · Cited by 1,496
Failure Mode and Effect Analysis: FMEA From Theory to Execution
Schneider, H. (1996) · Technometrics · doi:10.1080/00401706.1996.10484424 · Cited by 1,493
A Survey of Fault Detection, Isolation, and Reconfiguration Methods
Hwang, I., Kim, S., Kim, Y., & Seah, C. E. (2010) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2009.2026285 · Cited by 1,305
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Critical Design and Control Issues of Indoor Autonomous Mobile Robots: A Review
Niloy, M. A., Shama, A., Chakrabortty, R. K., Ryan, M. J., Badal, F. R., Tasneem, Z., Ahamed, M. H., Moyeen, S. I., Das, S. K., Ali, M. F., et al. (2021) · IEEE Access · doi:10.1109/access.2021.3062557 · Cited by 187
“Basic Block Diagram of Particle Swarm Optimization Algorithm [214].”
Self-citationFault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 138
Cheng, M., Zhou, J., Qian, W., Wang, B., Zhao, C., & Han, P. (2024) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000048 · Cited by 80
Pietrzak, P., & Wolkiewicz, M. (2023) · Sensors · doi:10.3390/s23041757 · Cited by 76
“Over the years, several methods have been developed for the diagnosis of the PMSM demagnetization [13].”
Method
Metadata
- Authors
- Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I.
- Affiliations
- Rajshahi University of Engineering and Technology (BD)
- Corresponding author
- Bhuiyan, Erphan A.
- ORCID
- Venue
- International Journal of Automation and Computing
- Published
- 2020-11-11
- Volume
- 17
- Issue
- 6
- Pages
- 763-787
- ISSN
- 1476-8186 (ISSN-L)
- 1751-8520
- OpenAlex
- W3098358675
- Cited by
- 68
- References
- 145
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 16 · 2023: 12 · 2022: 13 · 2021: 6
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Machine Intelligence Research (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Keywords
- permanent magnet synchronous motor, fault diagnosis, fault tolerance, electric drives, inverter faults, stator winding faults, sensor faults, insulation failure, torque ripple
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Survey on Fault Diagnosis and Fault Tolerant Methodologies for Permanent Magnet Synchronous Machines. https://app.cochat.ai/papers/10.1007/s11633-020-1250-3
- The paper
- Bhuiyan, E. A., Akhand, M. M. A., Das, S. K., Ali, M. F., Tasneem, Z., Islam, M. R., Saha, D. K., Badal, F. R., Ahamed, M. H., & Moyeen, S. I. (2020). A Survey on Fault Diagnosis and Fault Tolerant Methodologies for Permanent Magnet Synchronous Machines. International Journal of Automation and Computing. https://doi.org/10.1007/s11633-020-1250-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.