The Vibration Monitoring Methods and Signal Processing Techniques for Structural Health Monitoring: A Review
The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is usually used in measuring low-frequency vibration of less than 10 Hz, but it can also measure vibration up to 300 Hz [45].”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [45]
In the citing paper
“According to Goyal and Pabla [45], cepstrum analysis is important in gearbox diagnosis.”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [45]
In the citing paper
“WVD has several advantages such as better resolution than STFT, excellent accuracy, and window function is not needed for its analysis [45].”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [45]
In the citing paper
“HHT has several advantages such as low computational time, and it does not associate with any convolution [45].”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [45]
In the citing paper
“It requires very little processing power and can be directly computed by FFT or by converting the autocorrelation function [45].”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [45]
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564 · cited 2×
“introduced the HHT as a data analysis tool or an adaptive signal processing technique to extract the properties of stationary, non-stationary and transient signals, especially for timefrequency-energy representations [67].”
MethodA theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 1×
“factor is chosen as a power of two and it is generally implemented through a pair of lowpass and highpass wavelet filters [74].”
MethodProbability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Probability, Random Variables, and Stochastic Processes
Papoulis, A., & Hoffman, J. G. (1967) · Physics Today · doi:10.1063/1.3034123 · Cited by 4,107
Los Alamos National Lab., N. (. S., Doebling, S., USDOE, W., Farrar, C., Prime, M., & Shevitz, D. (1996) · doi:10.2172/249299 · Cited by 2,899 · cited 1×
“Natural frequencies are most widely used parameters in vibration based SHM, but alterations in these frequencies are not much valuable to determine the damages if not very accurate measurements are acquired or large levels of damage have appeared [9].”
Background(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Vibration Based Condition Monitoring: A Review
Carden, E. P., & Fanning, P. (2004) · Structural Health Monitoring · doi:10.1177/1475921704047500 · Cited by 1,543 · cited 2×
“the distortion identification functions) [11].”
BackgroundImproved time-frequency representation of multicomponent signals using exponential kernels
Choi, H.-I., & Williams, W. J. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/assp.1989.28057 · Cited by 1,299
Bogert, B. P. (1963) · Medical Entomology and Zoology · Cited by 1,108
Generalized Phase-Space Distribution Functions
Cohen, L. (1966) · Journal of Mathematical Physics · doi:10.1063/1.1931206 · Cited by 1,105 · cited 1×
“Cohen’s class (CC) distribution is a technique to evaluate the energy of time-varying systems [66].”
MethodP., A. L. (1948) · Nature · doi:10.1038/161503c0 · Cited by 1,015
Vibration‐based Condition Monitoring: Industrial, Aerospace and Automotive Applications
Randall, R. B. (2011) · Wiley eBooks · doi:10.1002/9780470977668 · Cited by 868 · cited 3×
“environments or to analyze the small and weal structures [21, 38].”
BackgroundMethod(1993) · Cited by 822
Sensor signals for tool-wear monitoring in metal cutting operations—a review of methods
Dimla, D. E. (2000) · International Journal of Machine Tools and Manufacture · doi:10.1016/s0890-6955(99)00122-4 · Cited by 696
Damage diagnosis using time series analysis of vibration signals
Sohn, H., & Farrar, C. R. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/3/304 · Cited by 569 · cited 1×
“The time series analysis of vibration signals was used to diagnose the damages in mechanical structures [49].”
MethodFault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512 · cited 1×
“This technique consumes a small amount of processing power, and it is used for fault diagnoses of induction machines [22].”
MethodBogert, B. P. (1963) · Medical Entomology and Zoology · Cited by 507
Vibration-based Condition Monitoring: Industrial, Aerospace and Automotive Applications
Randall, R. B. (2011) · Cited by 504
Joint time-frequency analysis : methods and applications
Qian, S., & Chen, D. (1996) · Cited by 489
Signal Processing Techniques for Vibration-Based Health Monitoring of Smart Structures
Amezquita-Sanchez, J. P., & Adeli, H. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9135-7 · Cited by 487 · cited 3×
“The various wavelets are used for structural health monitoring [48].”
BackgroundMethodInfluentialLaser Doppler Vibrometry: Development of advanced solutions answering to technology's needs
Castellini, P., Martarelli, M., & Tomasini, E. P. (2006) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2005.11.015 · Cited by 483
An improved Hilbert–Huang transform and its application in vibration signal analysis
Peng, Z. K., Tse, P. W., & Chu, F. L. (2005) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2004.10.005 · Cited by 463 · cited 1×
“and non-stationary signal, but it also has some shortcomings [80].”
BackgroundOn-line metal cutting tool condition monitoring.
Dimla, E., & Lister, P. M. (2000) · International Journal of Machine Tools and Manufacture · doi:10.1016/s0890-6955(99)00084-x · Cited by 394 · cited 1×
“A Kistler mini accelerometer is used to monitor the online condition of metal cutting tool, and to estimate the flank wear area in inserts for CNC turning [33, 34].”
MethodDetection of Rolling Element Bearing Damage by Statistical Vibration Analysis
Dyer, D., & Stewart, R. M. (1978) · Journal of Mechanical Design · doi:10.1115/1.3453905 · Cited by 354 · cited 1×
“The statistical parameter ‘kurtosis’ is used for predicting the condition of rolling element bearing by measuring the bearing housing vibration [54].”
MethodPractical Machinery Vibration Analysis and Predictive Maintenance
(2004) · Elsevier eBooks · doi:10.1016/b978-0-7506-6275-8.x5000-0 · Cited by 341 · cited 1×
“monitor the condition of the machine during startups, shutdowns and normal operations [17].”
BackgroundStaszewski, W. J., Worden, K., & Tomlinson, G. R. (1997) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1997.0102 · Cited by 329 · cited 1×
“A smooth pseudo The WVD is used to monitor the condition of the gearbox by detecting the broken tooth in a spur gear [70].”
MethodBAYDAR, N., & BALL, A. (2001) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.2000.1338 · Cited by 323 · cited 1×
“contrasting the acoustic and vibration signals to detect the failures in gear, and compare the time-frequency feature of cracked rotor [72, 73].”
BackgroundA summary of methods applied to tool condition monitoring in drilling
Jantunen, E. (2002) · International Journal of Machine Tools and Manufacture · doi:10.1016/s0890-6955(02)00040-8 · Cited by 322 · cited 1×
“In drilling, the direct measurements aren’t very efficient in economical and technical terms [19].”
BackgroundMODAL TESTING USING A SCANNING LASER DOPPLER VIBROMETER
STANBRIDGE, A. B., & EWINS, D. J. (1999) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1998.1209 · Cited by 302 · cited 1×
“The disadvantages include “speckle drop out” (the speckle noise can distort LDV signal), line of sight required from the laser head to the target, the time required for testing and demodulation of data [39].”
BackgroundCondition‐based maintenance: tools and decision making
Tsang, A. H. C. (1995) · Journal of Quality in Maintenance Engineering · doi:10.1108/13552519510096350 · Cited by 284
Mechanical Vibration and Shock Measurements
Broch, J. T. (1980) · Cited by 265
Rotating Machinery Vibration: From Analysis to Troubleshooting
Adams, M. L. (2000) · Thammasat University Digital Collections · Cited by 233
Condition Monitoring and Control for Intelligent Manufacturing
(2006) · Springer Series in Advanced Manufacturing · doi:10.1007/1-84628-269-1 · Cited by 200
Adeli, H., & Jiang, X. (2008) · CRC Press eBooks · doi:10.1201/9781482281767 · Cited by 194
Tool Wear Detection Using Time Series Analysis of Acoustic Emission
Liang, S. Y., & Dornfeld, D. A. (1989) · Journal of Engineering for Industry · doi:10.1115/1.3188750 · Cited by 186 · cited 1×
“The time series analysis of acoustic emission is also performed to monitor the wear of cutting tool [50].”
MethodAn integrated approach to fault diagnosis of machinery using wear debris and vibration analysis
Peng, Z., & Kessissoglou, N. (2003) · Wear · doi:10.1016/s0043-1648(03)00098-x · Cited by 163 · cited 1×
“the severity of the problem, whilst the frequency can indicate the source of the defect [5].”
Background(2008) · Medical Entomology and Zoology · Cited by 163
Damage identification in reinforced concrete structures by dynamic stiffness determination
Maeck, J., Wahab, M. M. A., Peeters, B., Roeck, G. D., Visscher, J. D., Wilde, W. P. D., Ndambi, J. M., & Vantomme, J. (2000) · Engineering Structures · doi:10.1016/s0141-0296(99)00074-7 · Cited by 146 · cited 1×
“Now, modern techniques are also available to directly convert the time domain data to modal domain data [45].”
BackgroundLawson, C. P., & Ivey, P. C. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2004.07.002 · Cited by 130 · cited 1×
“The vibration amplitude of turbomachinery blade has also been measured through tip timing with capacitance probe sensor [28].”
MethodAdams, M. L. (2000) · CRC Press eBooks · doi:10.1201/9780203902165 · Cited by 121 · cited 1×
“It is considered an optimum measurement method for rotor-to-stator position [26].”
MethodSilva, R., Reuben, R. L., Baker, K. J., & Wilcox, S. J. (1998) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1997.0123 · Cited by 115 · cited 1×
“These are employed to measure the vertical vibrations for tool wear monitoring of turning operations [32].”
MethodMechatronics: Electronic Control Systems in Mechanical and Electrical Engineering
Bolton, W. C. (2015) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.6477422 · Cited by 111
The Detection of Tool Breakage in Milling Operations
Altıntaş, Y., Yellowley, I., & Tlusty, J. (1988) · Journal of Engineering for Industry · doi:10.1115/1.3187881 · Cited by 106
Lawson, C. P., & Ivey, P. C. (2005) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(04)00482-0 · Cited by 106
Detecting damage in vibrating structures with a scanning LDV
Khan, A., Stanbridge, A. B., & Ewins, D. J. (1999) · Optics and Lasers in Engineering · doi:10.1016/s0143-8166(00)00004-x · Cited by 95
Vass, J., Šmíd, R., Randall, R. B., Sovka, P., Cristalli, C., & Torcianti, B. (2007) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2007.08.008 · Cited by 92 · cited 1×
“Currently, however, they are not really a viable option for regular condition monitoring, even though they are used in production quality control measurements [41].”
BackgroundAnalysis of earthquake ground motions using an improved Hilbert–Huang transform
Yinfeng, D., Li, Y., Mingkui, X., & Ming, L. (2007) · Soil Dynamics and Earthquake Engineering · doi:10.1016/j.soildyn.2007.05.002 · Cited by 89
Time-varying lapped transforms and wavelet packets
de Queiroz, R. L., & Rao, K. R. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.258074 · Cited by 84 · cited 1×
“In the improved version [81], wavelet packet transform (WPT) is used as a preprocessor to separate the analyzed signal”
MethodStructural Damage Detection in the Frequency Domain using Neural Networks
Lee, J., & Kim, S. (2007) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x06073640 · Cited by 78
A new capacitive sensor for displacement measurement in a surface-force apparatus
Restagno, F., Crassous, J., Charlaix, É., & Monchanin, M. (2000) · Measurement Science and Technology · doi:10.1088/0957-0233/12/1/302 · Cited by 77 · cited 1×
“These are allowed for dynamic measurement in a surface force apparatus within the range of 0-100 Hz [27].”
BackgroundShin, Y. S., & Jeon, J.-J. (1993) · Shock and Vibration · doi:10.1155/1993/372086 · Cited by 67
Zou, J., & Chen, J. (2004) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2003.07.002 · Cited by 65 · cited 11×
“The WVD is one of the so-called ‘Cohen’s class’ of time frequency distributions [60].”
BackgroundMethodInfluentialCEPSTRUM ANALYSIS AND GEARBOX FAULT DIAGNOSIS
Randall, R. B., & Rb, R. (1976) · Cited by 59
An Introduction to Optoelectronic Sensors
Righini, G. C., Tajani, A., & Cutolo, A. (2009) · Series in optics and photonics · doi:10.1142/6987 · Cited by 58 · cited 2×
“environments or to analyze the small and weal structures [21, 38].”
BackgroundMethodCondition Monitoring of Rotary Machines
Tandon, N., & Parey, A. (2006) · Springer series in advanced manufacturing · doi:10.1007/1-84628-269-1_5 · Cited by 57
Interpretation of crack-induced rotor non-linear response using instantaneous frequency
Yang, B., & Suh, C. S. (2003) · Mechanical Systems and Signal Processing · doi:10.1016/s0888-3270(03)00019-0 · Cited by 51 · cited 1×
“It is used for the crack-induced motor to interpret the non-linear response [78].”
MethodDetection of rolling element bearing defects by adaptive filtering
Khemili, I., & Chouchane, M. (2004) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2004.10.003 · Cited by 49 · cited 1×
“Too much noise in the vibration signals makes impossible to extract the useful information through signal processing techniques so Adaptive noise cancellation (ANC) is one such technique that enhances the signal to noise ratio [44].”
BackgroundShin, Y. S., & Jeon, J.-J. (1993) · Calhoun: The Naval Postgraduate School Institutional Archive (Naval Postgraduate School) · doi:10.3233/sav-1993-1109 · Cited by 44 · cited 1×
“a different frequency at each instant of time has a distinct frequency [58].”
BackgroundVibration-based estimation of tool major flank wear in a turning process using ARMA models
Aghdam, B. H., Vahdati, M., & Sadeghi, M. H. (2014) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-014-6296-3 · Cited by 44 · cited 1×
“turning process and establish the direct relation to the natural frequency of the tool/holder set by developing a metric calculated based eigen value system [51].”
MethodPiezoelectric-Based Degradation Assessment of a Pipe Using Fourier and Wavelet Analyses
Cheraghi, N., Zou, G. P., & Taheri, F. (2005) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/j.1467-8667.2005.00403.x · Cited by 44
FPGA-Based Fused Smart-Sensor for Tool-Wear Area Quantitative Estimation in CNC Machine Inserts
Trejo-Hernández, M., Osornio-Rios, R. A., Romero-Troncoso, R. D. J., Rodríguez-Donate, C., Domínguez-González, A., & Herrera-Ruíz, G. (2010) · Sensors · doi:10.3390/s100403373 · Cited by 41
Structural Health Monitoring: A Contribution to the Intelligent Aircraft Structure
Speckmann, H., & Roesner, H. (2006) · Cited by 38
Estimation of elastic and modal parameters in composites using vibration analysis
Yeşilyurt, İ., & Gursoy, H. (2013) · Journal of Vibration and Control · doi:10.1177/1077546313486275 · Cited by 32
Engine noise characterisation with Wigner-Ville time-frequency analysis
Chiollaz, M., & Favre, B. (1993) · Mechanical Systems and Signal Processing · doi:10.1006/mssp.1993.1022 · Cited by 30
Blading Vibration and Failures in Gas Turbines: Part B — Compressor and Turbine Airfoil Distress
Meher-Homji, C. B. (1995) · doi:10.1115/95-gt-419 · Cited by 27 · cited 2×
“Meher-Homji, C.B. (1995b).”
BackgroundIntroductory course on theory and practice of mechanical vibrations
Rao, J., & Gupta, K. K. (1985) · Wiley eBooks · Cited by 25
Self-Monitoring and Self-Healing Jointed Structures
Park, G., Muntges, D. E., & Inman, D. J. (2001) · Key engineering materials · doi:10.4028/www.scientific.net/kem.204-205.75 · Cited by 25 · cited 1×
“[43] suggests ‘level 5’ in the context of smart structures with emergence of shape memory alloys i.”
BackgroundAmézquita-Sánchez, J. P., García-Pérez, A., Romero-Troncoso, R. D. J., Osornio-Rios, R. A., & Herrera-Ruíz, G. (2012) · Journal of Vibration and Control · doi:10.1177/1077546312456228 · Cited by 23 · cited 1×
“Also, it doesn’t allow observing two closed natural frequencies [65].”
BackgroundHardware-software system for simulating and analyzing earthquakes applied to civil structures
Amézquita-Sánchez, J. P., Osornio-Rios, R. A., Romero-Troncoso, R. D. J., & Domínguez-González, A. (2012) · Natural hazards and earth system sciences · doi:10.5194/nhess-12-61-2012 · Cited by 22
Rotating Machinery: Practical Solutions to Unbalance and Misalignment
McMillan, R. B. (2003) · Cited by 21
Signal Processing in Manufacturing Monitoring
Li, C. J. (2006) · Springer eBooks · doi:10.1007/1-84628-269-1_10 · Cited by 20
Turbomachinery prognostics and health management via eddy current sensing: current developments
Dowell, M., & Sylvester, G. W. (1999) · IEEE Aerospace Conference (AERO) · doi:10.1109/aero.1999.789758 · Cited by 20 · cited 1×
“The prognostics and health management for jet engines and other turbomachinery are also described by eddy current sensing [25].”
BackgroundPresent Situation and Prospects of Vibration Sensors
Cao, Y. G., Rong, X. L., Shao, S., & He, K. P. (2012) · International Conference on Computer Distributed Control and Intelligent Environmental Monitoring · doi:10.1109/cdciem.2012.128 · Cited by 17
Forecasting Research Of Aero-engine Rotate Speed Signal Based on ARMA Model
Liu, Z., Cai, Z.-J., & Tan, X. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.08.024 · Cited by 13
Wavelet Analysis of Vibration Signals
Newland, D. E. (2007) · Wiley eBooks · doi:10.1002/9780470209707.ch49 · Cited by 11
Binaural Localization Based on Weighted Wiener Gain Improved by Incremental Source Attenuation
Nagata, Y., Iwasaki, S., Hariyama, T., Fujioka, T., Obara, T., Takayuki, W., & Abe, M. (2009) · IEEE Transactions on Audio Speech and Language Processing · doi:10.1109/tasl.2008.2006651 · Cited by 11
Calibration of Shock and Vibration Measuring Transducers
Bouche, R. R., & Saunders, H. (1982) · Journal of Mechanical Design · doi:10.1115/1.3256343 · Cited by 10 · cited 1×
“of the piezoelectric accelerometer include, light weight and high frequency range, compactness, ruggedness and high sensitivity [35]; the disadvantages are that these have a high output impedance that generate small voltages (order of 1mV), vulnerable to interference from the external environment, the weak output sign…”
BackgroundResearch on Vibration Sensor of Ultra Low Frequency
Li, Y. (2008) · Colliery Mechanical & Electrical Technology · Cited by 6
Machine tool vibrations and violin sound fields studied using laser vibrometry
Tatar, K. (2006) · Diva portal (Dalarna University Library) · Cited by 5
Research works printed but not linked: 8
- Fritzen CP, Balageas D, Güemes A (eds) (2006) Structural health monitoring, vol 493. ISTE, London
- Shah BM, Cannington JC, Ferko EJ, Kwon YS, Saunders SA, Phan N, Candela JM (2004) P-3C service life management. In: Proceedings of USAF ASIP conference
- Terpay GW, Zipfel Jr GG (1999) Measuring blade condition in a gas turbine engine using eddy-currents. In: Ninth international conference on adaptive structures and technologies. October 14–16, 1998, Boston, CRC, p 71
- Zhao-Hua W (2006) Capacitive sensor based on active bridge circuit and its measurement system. Beijing University of Chemical Technology Master Degree Thesis, 11
- Fu-Cheng X (2008) Common vibration sensor and its typical application circuit. Pract Electron 10:13–15
- Friswell MI, Penny JET (1997) Is damage location using vibration measurements, practical. In: Proceedings of EUROMECH 365 international workshop: DAMAS, vol 97
- Claasen TACM, Mecklenbrauker WFG (1980) The Wigner distribution—a tool for time–frequency signal analysis. Part I: continuous-time signals. Philips J Res 35(3):217–250
- Yang JN, Lei Y (2000) System identification of linear structures using Hilbert transform and empirical mode decomposition. In: SPIE proceedings series. Society of photo-optical instrumentation engineers, pp 213–219
Cited by
Zhang, C., Mousavi, A. A., Masri, S. F., Gholipour, G., Yan, K., & Li, X. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2022.109175 · Cited by 395
A Critical Review on Structural Health Monitoring: Definitions, Methods, and Perspectives
Gharehbaghi, V. R., Noroozinejad Farsangi, E., Noori, M., Yang, T. Y., Li, S., Nguyen, A., Málaga-Chuquitaype, C., Gardoni, P., & Mirjalili, S. (2022) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09665-9 · Cited by 330
“A summary review of vibration-based methods can be found in [35, 78, 79].”
BackgroundStructural Health Monitoring for Advanced Composite Structures: A Review
Güemes, A., Fernandez-Lopez, A., Pozo, A. R., & Sierra-Pérez, J. (2020) · Journal of Composites Science · doi:10.3390/jcs4010013 · Cited by 298
Condition Monitoring and Fault Diagnosis of Induction Motors: A Review
Choudhary, A., Goyal, D., Shimi, S. L., & Akula, A. (2019) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-018-9286-z · Cited by 302
Self-citationVibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review
Mohd Ghazali, M. H., & Rahiman, W. (2021) · Shock and Vibration · doi:10.1155/2021/9469318 · Cited by 249
“It is usually used in measuring low-frequency vibration of less than 10 Hz, but it can also measure vibration up to 300 Hz [45].”
BackgroundMethodInfluential
Metadata
- Authors
- Goyal, D., & Pabla, B. S.
- Affiliations
- National Institute of Technical Teachers Training and Research, Chandigarh (IN)
- National Institute of Technical Teachers’ Training and Research (IN)
- Corresponding author
- Goyal, D.
- Venue
- Archives of Computational Methods in Engineering
- Published
- 2015-03-10
- Volume
- 23
- Issue
- 4
- Pages
- 585-594
- ISSN
- 1134-3060 (ISSN-L)
- 1886-1784
- OpenAlex
- W2007030286
- Cited by
- 508
- References
- 78
- Citations by year
- 2026: 48 · 2025: 84 · 2024: 70 · 2023: 62 · 2022: 53 · 2021: 41 · 2020: 57 · 2019: 41 · 2018: 27 · 2017: 12 · 2016: 12 · 2015: 1
- FWCI
- 16.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Archives of Computational Methods in Engineering (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Mechanical Engineering › Advanced machining processes and optimization
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
- Keywords
- vibration monitoring, structural health monitoring, signal processing, machining operations, non-contact vibration measurement, machine condition monitoring, predictive maintenance, rotating machinery, manufacturing quality assurance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.