Non-invasive Mapping of Cardiac Arrhythmias
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Since more than 100 years, 12-lead electrocardiography (ECG) is the standard-of-care tool, which involves measuring electrical potentials from limited sites on the body surface to diagnose cardiac disorder, its possible mechanism, and the likely site of origin. Several decades of research has led to the development of a 252-lead ECG and computed tomography (CT) scan-based three-dimensional electro-imaging modality to non-invasively map abnormal cardiac rhythms including fibrillation. These maps provide guidance towards ablative therapy and thereby help advance the management of complex heart rhythm disorders. Here, we describe the clinical experience obtained using non-invasive technique in mapping the electrical disorder and guide the catheter ablation of atrial arrhythmias (premature atrial beat, atrial tachycardia, atrial fibrillation), ventricular arrhythmias (premature ventricular beats), and ventricular pre-excitation (Wolff-Parkinson-White syndrome).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BSPM has nowadays got a real clinical breakthrough as a method for non-invasive 3D EAI, with the competitive concept of “ECG imaging” (ECGi) (239–241), a technology that has rapidly evolved in clinically available devices (242), increasingly used for non-invasive pre-interventional assessment of patients undergoing catheter ablation procedures (243, 244).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [243]
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Self-citationBraunwald's Heart Disease: A Textbook of Cardiovascular Medicine
Mann, D. L., Zipes, D. P., Libby, P., Bonow, R. O., & D, E. B. M. (2011) · Medical Entomology and Zoology · Cited by 3,745
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationTreatment of Atrial Fibrillation by the Ablation of Localized Sources
Narayan, S. M., Krummen, D. E., Shivkumar, K., Clopton, P., Rappel, W.-J., & Miller, J. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.022 · Cited by 1,117
Driver domains in persistent atrial fibrillation
Haissaguerre, M., Hocini, M., Denis, A., Shah, A. J., Komatsu, Y., Yamashita, S., Daly, M., Amraoui, S., Zellerhoff, S., Picat, M.-Q., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005421 · Cited by 734
Self-citationMother rotors and fibrillatory conduction: a mechanism of atrial fibrillation
Jalife, J. (2002) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00223-7 · Cited by 587
Solutions of ill-posed problems
Tikhonov, A. N., & Arsenin, V. Y. (1977) · International Linear Collider · Cited by 574
Research works printed but not linked: 1
- Rudy Y, Oster HS. Crit Rev Biomed Eng. 1992;20:25–45.
Cited by
The role of catheter ablation in the management of ventricular tachycardia
Tanawuttiwat, T., Nazarian, S., & Calkins, H. G. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv421 · Cited by 83
“65 Therefore, it is very important to have a 12-lead ECG of clinical (spontaneous) VT available to help identify and target the clinical VT.”
MethodInfluentialClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Persistent atrial fibrillation vs paroxysmal atrial fibrillation: differences in management
Margulescu, A. D., & Mont, L. (2017) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2017.1355237 · Cited by 79
“The anatomy of the heart and its spatial relationship to the unipolar electrodes is documented using computed tomography [102].”
MethodCheniti, G., Puyo, S., Martin, C., Frontera, A., Vlachos, K. G., Takigawa, M., Bourier, F. J., Kitamura, Τ., Lam, A., Dumas-Pomier, C., et al. (2019) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2019.05.004 · Cited by 35
Self-citationBeltrami, M., Palazzuoli, A., Padeletti, L., Cerbai, E., Coiro, S., Emdin, M., Marcucci, R., Morrone, D., Cameli, M., Savino, K., et al. (2017) · International Journal of Clinical Practice · doi:10.1111/ijcp.13050 · Cited by 26
Noninvasive cardiac arrhythmia ablation with particle beams
Graeff, C., & Bert, C. (2018) · Medical Physics · doi:10.1002/mp.12595 · Cited by 26
“Achieving one key-benefit of radiation therapy based arrhythmia treatment, namely noninvasiveness, seems also feasible since recently noninvasive mapping techniques were reported.(29,30)”
Electrocardiographic imaging in the atria
Hernández‐Romero, I., Molero, R., Santos, C. F., Herrero-Martín, C., Climent, A. M., & Guillem, M. S. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02709-7 · Cited by 24
“In this sense, the inverse problem of electrocardiography or electrocardiographic imaging (ECGI) can provide an extra value as an estimation of the electrical information over cardiac surfaces from non-contact recordings [11].”
BackgroundShi, R., Norman, M. W., Chen, Z., & Wong, T. (2018) · Future Cardiology · doi:10.2217/fca-2017-0109 · Cited by 22
Dilaveris, P., Antoniou, C. K., & Gatzoulis, K. A. (2017) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.06.003 · Cited by 16
“tomography could provide the necessary data(71, 72).”
Atrial Abnormalities in Brugada Syndrome
Bisignani, A., Pannone, L., Monte, A. D., Eltsov, I., Cappello, I. A., Sieira, J. A., Monaco, C., Bala, G., Mouram, S., Rocca, D. G. D., et al. (2023) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.06.011 · Cited by 13
Graham, A. J., & SCHILLING, R. J. (2021) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2021.27 · Cited by 10
Advanced Mapping and Navigation Modalities
Issa, Z. F., Miller, J. M., & Zipes, D. P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-52356-1.00006-2 · Cited by 10
Sörnmo, L., Alcaraz, R., Laguna, P., & Rieta, J. J. (2018) · Series in bioengineering · doi:10.1007/978-3-319-68515-1_6 · Cited by 11
High-Resolution Body Surface Potential Mapping in Exercise Assessment of Ischemic Heart Disease
Kania, M., Maniewski, R., Zaczek, R., Kobylecka, M., Zbiec, A., Królicki, L., & Opolski, G. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02231-2 · Cited by 9
Dhillon, G. S., Honarbakhsh, S., Graham, A. J., Abbass, H., Welch, S., Daw, H., Sporton, S. C., Providencia, R. A., CHOW, A. W. C., Earley, M. J., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15644 · Cited by 5
“ECGI has been used in several studies to record PD data and has been validated in terms of mapping focal and re‐entrant tachycardias.(29) To date, there have been limited studies published using ECGI in AF.”
Mayorca-Torres, D., Salas, A. L., & Peluffo-Ordóñez, D. H. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03264-z · Cited by 4
“ECGI has proven invaluable in guiding catheter ablation for arrhythmias and ventricular pre-excitation [129], as well as in managing heart failure, cardiac resynchronization therapy [102,151],anddiagnosingandtreatingatrialarrhythmiasand ventricular tachycardia [122, 130].”
Catheter Ablation for Ventricular Tachycardia in Patients with Nonischemic Cardiomyopathy
Thompson, N. C., Frontera, A., Takigawa, M., Cheniti, G., Massoullié, G., Cochet, H., Denis, A., Chaumeil, A., Derval, N., Hocini, M., et al. (2016) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2016.10.003 · Cited by 4
Self-citationArtyukhina, Е. А., Yashkov, М. V., Викторовна, Д. Е., Азатовна, Т. И., & Revishvili, A. S. (2022) · Patologiya krovoobrashcheniya i kardiokhirurgiya · doi:10.21688/1681-3472-2022-1-73-82 · Cited by 2
“Время флюороскопии в группе ПНЭК составило 35,3 мин, в группе контроля 24,4 мин [5].”
Gagyi, R. B., Hoogendijk, M. G., Yap, S., & Szili‐Törok, T. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.2012449 · Cited by 2
“Cardiac mapping has evolved in the last few years from a direct single point-by-point registration of electrical activity to furthermost complex multimodal real-time techniques [5,16].”
BackgroundAdvances in Atrial Fibrillation Ablation
Verma, A., & Shenasa, M. (2019) · Wiley eBooks · doi:10.1002/9781119152637.ch20 · Cited by 1
Geschichte der Katheterablation
Pfeiffer, D., Tebbenjohanns, J., Klein, N., Metze, M., & Neef, M. (2019) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-019-00661-y
Peruzza, F., Maines, M., Angheben, C., Moggio, P., Catanzariti, D., & Greco, M. D. (2021) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2021.01.019
“Its efficacy has been demonstrated in a variety of arrhythmic scenarios, ranging from the mapping of premature ventricular complex and accessory pathways to the mapping of complex arrhythmias such as atrial fibrillation and ventricular tachycardia.(12,13) To our knowledge, this is the first report that describes the u…”
BackgroundNovel interventional methods for catheter ablation in the treatment of brief cardiac arrhythmias
Gagyi, R. B. (2025) · SZTE Repository of Dissertations (University of Szeged) · doi:10.14232/phd.12343
Metadata
- Authors
- Shah, A., Hocini, M., Haissaguerre, M., & Jaïs, P.
- Affiliations
- Université de Bordeaux (FR)
- ORCID
- Shah, Ashok
- Venue
- Current Cardiology Reports
- Published
- 2015-06-14
- Volume
- 17
- Issue
- 8
- Pages
- 60-60
- ISSN
- 1523-3782 (ISSN-L)
- 1534-3170
- OpenAlex
- W644229815
- Semantic Scholar
- 00547cf5a0aff3b810d3b4f84f50fac54e94e3de
- Cited by
- 22
- References
- 43
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2019: 5 · 2018: 3 · 2017: 3 · 2016: 1 · 2015: 1
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Current Cardiology Reports (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- cardiac arrhythmias, atrial fibrillation, atrial tachycardia, atrial arrhythmias, ventricular arrhythmias, premature ventricular contractions, Wolff-Parkinson-White syndrome, catheter ablation
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Heart, Humans, Models, Cardiovascular, Imaging, Three-Dimensional, Electrophysiologic Techniques, Cardiac
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.