Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study

Open access
Lonner, Jess H., John, Thomas K., Conditt, Michael A.·2010·Clinical Orthopaedics & Related Research

Abstract

UNLABELLED: The alignment of the components of unicompartmental knee arthroplasty (UKA) reportedly influences outcomes and durability. A novel robotic arm technology has been developed with the expectation that it could improve the accuracy of bone preparation in UKA. During the study period, we compared the postoperative radiographic alignment of the tibial component with the preoperatively planned position in 31 knees in 31 consecutive patients undergoing UKA using robotic arm-assisted bone preparation and in 27 consecutive patients who underwent unilateral UKA using conventional manual instrumentation to determine the error of bone preparation and variance with each technique. Radiographically, the root mean square error of the posterior tibial slope was 3.1 degrees when using manual techniques compared with 1.9 degrees when using robotic arm assistance for bone preparation. In addition, the variance using manual instruments was 2.6 times greater than the robotically guided procedures. In the coronal plane, the average error was 2.7 degrees +/- 2.1 degrees more varus of the tibial component relative to the mechanical axis of the tibia using manual instruments compared with 0.2 degrees +/- 1.8 degrees with robotic technology, and the varus/valgus root mean square error was 3.4 degrees manually compared with 1.8 degrees robotically. Further study will be necessary to determine whether a reduction in alignment errors of these magnitudes will ultimately influence implant function or survival. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s11999-009-0977-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Lonner, J. H., John, T. K., & Conditt, M. A.
Venue
Clinical Orthopaedics & Related Research
Published
2010-01
Volume
468
Issue
1
Pages
141-146
ISSN
0009-921X (ISSN-L)
OpenAlex
W2012458472
Cited by
215
References
0
FWCI
4.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study. https://app.cochat.ai/papers/10.1007/s11999-009-0977-5
The paper
Lonner, J. H., John, T. K., & Conditt, M. A. (2010). Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study. Clinical Orthopaedics & Related Research. https://doi.org/10.1007/s11999-009-0977-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.