Effects of serum and plasma matrices on multiplex immunoassays
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Multiplexed fluorescence or electrochemiluminescence immunoassays of soluble cytokines are commonly performed in the context of human serum or plasma, to look for disease biomarkers and to monitor the immune system in a simple and minimally invasive way. These assays provide challenges due to the complexities of the matrix (serum or plasma) and the presence of many cytokines near the limit of detection of the assay. Here, we compare the readout of matched serum and plasma samples, which are generally correlated. However, a subset of cytokines usually have higher levels in serum, and the non-specific background is significantly increased in serum versus plasma. Presumably as a result of this non-specific background, disease-related decreases in low-abundance cytokines can sometimes be detected in plasma but not in serum. We further show, through spike recovery experiments, that both serum and plasma inhibit the readout of many cytokines, with some variability between donors, but with serum causing greater inhibition than plasma in many cases. Standard diluents from different vendors can partially reverse this inhibition to varying degrees. Dilution of samples can also partly overcome the inhibitory effect of the matrix. We also show that dilution is nonlinear and differentially affects various cytokines. Together, these data argue that (1) plasma is a more sensitive matrix for detecting changes in certain low-abundance cytokines; (2) calculation of concentrations in serum or plasma matrices is inherently inaccurate; and (3) dilution of samples should not be assumed to be linear, i.e., all comparisons need to be made among similarly diluted samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays
de Jager, W., Bourcier, K., Rijkers, G. T., Prakken, B. J., & Seyfert-Margolis, V. (2009) · BMC Immunology · doi:10.1186/1471-2172-10-52 · Cited by 427
Cited by
Cytokines: From Clinical Significance to Quantification
Liu, C., Chu, D., Kalantar‐Zadeh, K., George, J., Young, H. A., & Liu, G. (2021) · Advanced Science · doi:10.1002/advs.202004433 · Cited by 940
Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials
Sena-Torralba, A., Álvarez-Diduk, R., Parolo, C., Piper, A., & Merkoçi, A. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c01012 · Cited by 388
Inflammation and the dimensions of depression: A review
Majd, M., Saunders, E. F. H., & Engeland, C. G. (2020) · Frontiers in Neuroendocrinology · doi:10.1016/j.yfrne.2019.100800 · Cited by 217
Masucci, G. V., Cesano, A., Hawtin, R., Janetzki, S., Zhang, J., Kirsch, I., Dobbin, K. K., Alvarez, J., Robbins, P. B., Selvan, S. R., et al. (2016) · Journal for ImmunoTherapy of Cancer · doi:10.1186/s40425-016-0178-1 · Cited by 202
“…differences exist in the protein profile of plasma and serum, it is important that once chosen as the primary sample type either serum or plasma is consistently used during the entire course of the validation of a blood biomarker test, unless these fluids have been shown to be interchangeable [90].”
BackgroundLu, R., Munroe, M. E., Guthridge, J. M., Bean, K. M., Fife, D. A., Chen, H., Slight-Webb, S. R., Keith, M. P., Harley, J. B., & James, J. A. (2016) · Journal of Autoimmunity · doi:10.1016/j.jaut.2016.06.001 · Cited by 164
“After performing quality control as described previously [32], four mediators (IFN-α, TNF-α, IL-10, and IL-15) were excluded from further analysis due ≥ 50% of cytokine measurements falling below the lowest level of detection [33].”
Method
Metadata
- Authors
- Rosenberg-Hasson, Y., Hansmann, L., Liedtke, M., Herschmann, I., & Maecker, H. T.
- Venue
- Immunologic Research
- Published
- 2014-02-13
- Volume
- 58
- Issue
- 2-3
- Pages
- 224-233
- ISSN
- 0257-277X (ISSN-L)
- 1559-0755
- OpenAlex
- W2053003735
- Cited by
- 152
- References
- 1
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of serum and plasma matrices on multiplex immunoassays. https://app.cochat.ai/papers/10.1007/s12026-014-8491-6
- The paper
- Rosenberg-Hasson, Y., Hansmann, L., Liedtke, M., Herschmann, I., & Maecker, H. T. (2014). Effects of serum and plasma matrices on multiplex immunoassays. Immunologic Research. https://doi.org/10.1007/s12026-014-8491-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.