Abstract
Cool roofs—roofs that stay cool in the sun by minimizing solar absorption and maximizing thermal emission—lessen the flow of heat from the roof into the building, reducing the need for space cooling energy in conditioned buildings. Cool roofs may also increase the need for heating energy in cold climates. For a commercial building, the decrease in annual cooling load is typically much greater than the increase in annual heating load. This study combines building energy simulations, local energy prices, local electricity emission factors, and local estimates of building density to characterize local, state average, and national average cooling energy savings, heating energy penalties, energy cost savings, and emission reductions per unit conditioned roof area. The annual heating and cooling energy uses of four commercial building prototypes—new office (1980+), old office (pre-1980), new retail (1980+), and old retail (pre-1980)—were simulated in 236 US cities. Substituting a weathered cool white roof (solar reflectance 0.55) for a weathered conventional gray roof (solar reflectance 0.20) yielded annually a cooling energy saving per unit conditioned roof area ranging from 3.30 kWh/m2 in Alaska to 7.69 kWh/m2 in Arizona (5.02 kWh/m2 nationwide); a heating energy penalty ranging from 0.003 therm/m2 in Hawaii to 0.14 therm/m2 in Wyoming (0.065 therm/m2 nationwide); and an energy cost saving ranging from 0.126/m2 in West Virginia to 1.14/m2 in Arizona ( 0.356/m2 nationwide). It also offered annually a CO2 reduction ranging from 1.07 kg/m2 in Alaska to 4.97 kg/m2 in Hawaii (3.02 kg/m2 nationwide); an NOx reduction ranging from 1.70 g/m2 in New York to 11.7 g/m2 in Hawaii (4.81 g/m2 nationwide); an SO2 reduction ranging from 1.79 g/m2 in California to 26.1 g/m2 in Alabama (12.4 g/m2 nationwide); and an Hg reduction ranging from 1.08 μg/m2 in Alaska to 105 μg/m2 in Alabama (61.2 μg/m2 nationwide). Retrofitting 80% of the 2.58 billion square meters of commercial building conditioned roof area in the USA would yield an annual cooling energy saving of 10.4 TWh; an annual heating energy penalty of 133 million therms; and an annual energy cost saving of 735 million. It would also offer an annual CO2 reduction of 6.23 Mt, offsetting the annual CO2 emissions of 1.20 million typical cars or 25.4 typical peak power plants; an annual NOx reduction of 9.93 kt, offsetting the annual NOx emissions of 0.57 million cars or 65.7 peak power plants; an annual SO2 reduction of 25.6 kt, offsetting the annual SO2 emissions of 815 peak power plants; and an annual Hg reduction of 126 kg.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calculating energy-saving potentials of heat-island reduction strategies
Akbari, H., & Konopacki, S. (2005) · Energy Policy · doi:10.1016/j.enpol.2003.10.001 · Cited by 360
Self-citationAkbari, H., Konopacki, S., & Pomerantz, M. (1999) · Energy · doi:10.1016/s0360-5442(98)00105-4 · Cited by 217
Self-citationInclusion of cool roofs in nonresidential Title 24 prescriptive requirements
Levinson, R., Akbari, H., Konopacki, S., & Bretz, S. (2005) · Energy Policy · doi:10.1016/s0301-4215(03)00206-4 · Cited by 123
Self-citationModeling the effects of reflective roofing
Gartland, L. M., Konopacki, S., & Akbari, H. (1996) · University of North Texas Digital Library (University of North Texas) · Cited by 30
Self-citationKonopacki, S. (1998) · eScholarship (California Digital Library) · Cited by 21
Levinson, R., Akbari, H., & Gartland, L. M. (1996) · University of North Texas Digital Library (University of North Texas) · Cited by 16
Self-citation
Research works printed but not linked: 7
- Akbari, H., Eto, J., Turiel, I., Heinemeier, K., Lebot, B., Nordman, B., & Rainer, L. (1989). Integrated estimation of commercial sector end-use load shapes and energy use intensities (Report No. LBL-27512). Berkeley, CA: Lawrence Berkeley National Laboratory. · doi:10.2172/7260522
- Akbari, H., Rainer, L., & Eto, J. (1991). Integrated estimation of commercial sector end-use load shapes and energy use intensities, Phase II (Report No. LBL-30401). Berkeley, CA: Lawrence Berkeley National Laboratory. · doi:10.2172/5297856
- Akbari, H., Konopacki, S., Parker, D., Wilcox, B., Eley, C., & Van Geem, M. (1998). Calculations in support of SSP90.1 for reflective roofs. ASHRAE Transactions, 104(1B), 984–995.
- Energy Information Administration (EIA) (1979). Commercial buildings consumption and expenditures (nonresidential buildings energy consumption survey). Washington, DC: US Department of Energy.
- Energy Information Administration (EIA) (1983). Commercial buildings consumption and expenditures (nonresidential buildings energy consumption survey). Washington, DC: US Department of Energy.
- Energy Information Administration (EIA) (1994a). Commercial buildings consumption and expenditures. Washington, DC: US Department of Energy.
- Konopacki, S., Akbari, H., Pomerantz, M., Gabersek, S., & Gartland, L. (1997). Cooling energy savings potential of light-colored roofs for residential and commercial buildings in 11 US metropolitan areas (Report No. LBNL-39433). Berkeley, CA: Lawrence Berkeley National Laboratory.
Cited by
A review on the development of cool pavements to mitigate urban heat island effect
Qin, Y. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.177 · Cited by 596
Paints as a Scalable and Effective Radiative Cooling Technology for Buildings
Mandal, J., Yang, Y., Yu, N., & Raman, A. P. (2020) · Joule · doi:10.1016/j.joule.2020.04.010 · Cited by 595
Ulpiani, G. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141727 · Cited by 562
Feng, W., Zhang, Q., Ji, H., Wang, R., Zhou, N., Ye, Q., Hao, B., Li, Y., Luo, D., & Lau, S. S. Y. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109303 · Cited by 329
Lu, X., Xu, P., Wang, H., Yang, T., & Hou, J. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.07.058 · Cited by 299
Yang, J., Wang, Z.-H., & Kaloush, K. E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.03.092 · Cited by 290
State of the art on the development of cool coatings for buildings and cities
Pisello, A. L. (2017) · Solar Energy · doi:10.1016/j.solener.2017.01.068 · Cited by 272
Designing Mesoporous Photonic Structures for High-Performance Passive Daytime Radiative Cooling
Chen, M., Pang, D., Mandal, J., Chen, X., Yan, H., He, Y., Yu, N., & Yang, Y. (2021) · Nano Letters · doi:10.1021/acs.nanolett.0c04241 · Cited by 254
Cool pavements for urban heat island mitigation: A synthetic review
Wang, C., Wang, Z.-H., Kaloush, K. E., & Shacat, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111171 · Cited by 214
Dabaieh, M., Wanas, O., Hegazy, M. A., & Johansson, E. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.034 · Cited by 190
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Self-citationThermal performance of reflective materials applied to exterior building components—A review
Hernández-Pérez, I., Álvarez, G., Xamán, J., Zavala-Guillén, I., Arce, J., & Simá, E. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.05.008 · Cited by 167
Falasca, S., Ciancio, V., Salata, F., Golasi, I., Rosso, F., & Curci, G. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106242 · Cited by 147
Comprehensive evaluation of thermal and energy performance of radiative roof cooling in buildings
Chen, J., & Lu, L. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101631 · Cited by 93
Sun, K., Zhang, W., Zeng, Z., Levinson, R., Wei, M., & Hong, T. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111383 · Cited by 86
Self-citationDesign, characterization, and fabrication of solar-retroreflective cool-wall materials
Levinson, R., Chen, S., Slack, J., Goudey, H., Harima, T., & Berdahl, P. (2020) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2019.110117 · Cited by 49
Self-citationSghiouri, H., Charai, M., Mezrhab, A., & Karkri, M. (2020) · Building Simulation · doi:10.1007/s12273-019-0562-0 · Cited by 42
Metadata
- Authors
- Levinson, R., & Akbari, H.
- Venue
- Energy Efficiency
- Published
- 2009-03-14
- Volume
- 3
- Issue
- 1
- Pages
- 53-109
- ISSN
- 1570-646X (ISSN-L)
- 1570-6478
- OpenAlex
- W2014997056
- Cited by
- 264
- References
- 6
- FWCI
- 16.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- creativecommons.org/licenses/by-nc/2.0 (tdm)
- creativecommons.org/licenses/by-nc/2.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.