A performance comparison of sensitivity analysis methods for building energy models
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global sensitivity indices for nonlinear mathematical models and their monte carlo estimates
Sobol′, I. M. (2001) · Mathematics and Computers in Simulation · doi:10.1016/s0378-4754(00)00270-6 · Cited by 6,389 · cited 1×
“The calculation of the Sobol sensitivity indices imperatively needs the input sample generated by the Sobol sequence (Sobol 2001).”
MethodFactorial Sampling Plans for Preliminary Computational Experiments
Morris, M. D. (1991) · Technometrics · doi:10.1080/00401706.1991.10484804 · Cited by 4,943
Sensitivity Estimates for Nonlinear Mathematical Models
Sobol, I. M. (1990) · Medical Entomology and Zoology · Cited by 2,806
A Quantitative Model-Independent Method for Global Sensitivity Analysis of Model Output
Saltelli, A., Tarantola, S., & Chan, K. P.-S. (1999) · Technometrics · doi:10.1080/00401706.1999.10485594 · Cited by 2,275
An effective screening design for sensitivity analysis of large models
Campolongo, F., Cariboni, J., & Saltelli, A. (2007) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2006.10.004 · Cited by 2,011 · cited 3×
“…that used or supported the Sobol method as the reference method (Saltelli and Bolado 1998; Ridolfi 2013; Massmann and Holzmann 2012; Wainwright et al. 2013; Confalonieri et al. 2010; Campolongo et al. 2007; Yang 2011), the Sobol method was considered the reference method for further investigations.”
BackgroundMethodA review of techniques for parameter sensitivity analysis of environmental models
Hamby, D. M. (1994) · Environmental Monitoring and Assessment · doi:10.1007/bf00547132 · Cited by 1,952
A review on simulation-based optimization methods applied to building performance analysis
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.061 · Cited by 1,379 · cited 2×
“Many studies have indicated that building simulation outputs are generally nonlinear, multimodal, discontinuous (Nguyen et al. 2014; Kampf et al. 2010), thus non-differentiable”
BackgroundSelf-citationA review of sensitivity analysis methods in building energy analysis
Tian, W. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.12.014 · Cited by 977 · cited 2×
“Table 1: SA methods investigated in this study and their basic features (adapted from (Morris 1991; Sobol 1993; Hamby 1994; Frey et al. 2003; Giglioli and Saltelli 2008; Tian 2013; Saltelli et al. 2004; Nossent el al. 2011))”
MethodKendall, M. G., & Smith, B. B. (1939) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177732186 · Cited by 944 · cited 3×
“We performed chisquare tests to see whether an observed value of KCC is significant, using the test method of Kendall and Smith (1939).”
MethodEldred, M., Dalbey, K., Bohnhoff, W., Adams, B., Swiler, L., Hough, P., Gay, D., Eddy, J., & Haskell, K. (2010) · doi:10.2172/991842 · Cited by 776
Sobol’ sensitivity analysis of a complex environmental model
Nossent, J., Elsen, P., & Bauwens, W. (2011) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2011.08.010 · Cited by 738
Nonlinear sensitivity analysis of multiparameter model systems
Cukier, R. I., Levine, H. B., & Shuler, K. E. (1978) · Journal of Computational Physics · doi:10.1016/0021-9991(78)90097-9 · Cited by 694
Sensitivity measures,anova-like Techniques and the use of bootstrap
Archer, G. E. B., Saltelli, A., & Sobol, I. M. (1997) · Journal of Statistical Computation and Simulation · doi:10.1080/00949659708811825 · Cited by 545 · cited 2×
“…non-monotonic function, namely the “g-function” (Model 7 in reference (Campolongo et al. 2000), (Saltelli and Sobol 1995; Saltelli and Bolado 1998; Archer et al. 1997; Helton and Davis 2002)), which is defined by: 1 1 4 2 ( ) ( ) 1 n n i i i i i i i x a f x g x a (3) The function f(x)…”
BackgroundSensitivity Analysis in Practice: A Guide to Assessing Scientific Models
Saltelli, A., Tarantola, S., Campolongo, F., & Ratto, M. (2002) · Wiley eBooks · doi:10.1002/0470870958 · Cited by 490 · cited 5×
“SA has been conceived and defined as a measure of the effect of a given input on the output (Saltelli et al. 2004).”
BackgroundMethodInfluentialUncertainty analysis in building performance simulation for design support
Hopfe, C. J., & Hensen, J. L. M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.06.034 · Cited by 457 · cited 3×
“Hopfe and Hensen (2011) performed uncertainty analysis and SA on three groups of input parameters of an office building, including: physical parameters, design parameters and scenario parameters.”
BackgroundMethodAn alternative way to compute Fourier amplitude sensitivity test (FAST)
Saltelli, A., & Bolado, R. (1998) · Computational Statistics & Data Analysis · doi:10.1016/s0167-9473(97)00043-1 · Cited by 367 · cited 6×
“All variables were considered continuous and their probability distribution functions are uniform (Saltelli and Bolado 1998; Archer et al. 1997; Campolongo et al. 2000; Helton and Davis 2002).”
BackgroundMethodInfluentialApplication of sensitivity analysis in design of sustainable buildings
Heiselberg, P., Brohus, H., Hesselholt, A., Rasmussen, H., Seinre, E., & Thomas, S. (2009) · Renewable Energy · doi:10.1016/j.renene.2009.02.016 · Cited by 359 · cited 2×
“FAST* sensitivity index Screeningbased method (Heiselberg et al. 2009) 9.”
MethodAbout the use of rank transformation in sensitivity analysis of model output
Saltelli, A., & Sobol', I. M. (1995) · Reliability Engineering & System Safety · doi:10.1016/0951-8320(95)00099-2 · Cited by 340 · cited 1×
“…third test was performed using a strongly nonlinear non-monotonic function, namely the “g-function” (Model 7 in reference (Campolongo et al. 2000), (Saltelli and Sobol 1995; Saltelli and Bolado 1998; Archer et al. 1997; Helton and Davis 2002)), which is defined by: 1 1 4 2 ( ) ( ) 1 n n i i i…”
MethodConvergence and uncertainty analyses in Monte-Carlo based sensitivity analysis
Yang, J. (2011) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2010.10.007 · Cited by 326 · cited 3×
“…that used or supported the Sobol method as the reference method (Saltelli and Bolado 1998; Ridolfi 2013; Massmann and Holzmann 2012; Wainwright et al. 2013; Confalonieri et al. 2010; Campolongo et al. 2007; Yang 2011), the Sobol method was considered the reference method for further investigations.”
MethodResultIllustration of Sampling‐Based Methods for Uncertainty and Sensitivity Analysis
Helton, J. C., & Davis, F. J. (2002) · Risk Analysis · doi:10.1111/0272-4332.00041 · Cited by 312 · cited 6×
“The first test function is a linear function (Model 3, reference (Campolongo et al. 2000; Helton and Davis 2002)) which is defined by:”
BackgroundMethodInfluentialHelton, J. C., Davis, F. J., & Johnson, J. D. (2005) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2004.09.006 · Cited by 278 · cited 3×
“Particularly, Helton et al. (2005) compared the SA results obtained by different sampling strategies and they recommended the LHS.”
MethodResultSensitivity analysis of energy performance of office buildings
Lam, J. C., & Hui, S. C. M. (1996) · Building and Environment · doi:10.1016/0360-1323(95)00031-3 · Cited by 243 · cited 2×
“Lam and Hui (1996) performed a study on the effects of various design parameters on building energy consumption.”
BackgroundComparison of sensitivity analysis techniques: A case study with the rice model WARM
Confalonieri, R., Bellocchi, G., Bregaglio, S., Donatelli, M., & Acutis, M. (2010) · Ecological Modelling · doi:10.1016/j.ecolmodel.2010.04.021 · Cited by 238 · cited 4×
“…that used or supported the Sobol method as the reference method (Saltelli and Bolado 1998; Ridolfi 2013; Massmann and Holzmann 2012; Wainwright et al. 2013; Confalonieri et al. 2010; Campolongo et al. 2007; Yang 2011), the Sobol method was considered the reference method for further investigations.”
MethodResultInfluentialAn adaptive thermal comfort model for hot humid South-East Asia
Nguyen, A. T., Singh, M. K., & Reiter, S. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.03.021 · Cited by 228 · cited 1×
“The comfort assessment method in this EnergyPlus model was based on the adaptive thermal comfort theory and the result of a comprehensive metaanalysis conducted by the authors (Nguyen et al. 2012).”
MethodSelf-citation96/05445 Sensitivity analysis of energy performance of office buildings
(1996) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(96)80114-7 · Cited by 193
Uncertainty and sensitivity decomposition of building energy models
Eisenhower, B., O'Neill, Z., Fonoberov, V. A., & Mezić, I. (2012) · Journal of Building Performance Simulation · doi:10.1080/19401493.2010.549964 · Cited by 168 · cited 1×
“In Eisenhower et al. (2012), the authors proposed and applied a decomposition of sensitivity indices to quantify which intermediate processes (e.g. Air handling unit, heating sources, cooling sources…) contributed the most to the uncertainty of building simulation outputs.”
BackgroundUncertainties and sensitivity analysis in building energy simulation using macroparameters
Calleja Rodríguez, G., Carrillo Andrés, A., Domínguez Muñoz, F., Cejudo López, J. M., & Zhang, Y. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.009 · Cited by 164 · cited 1×
“As an example, some studies (Yang 2011; Rodríguez et al. 2013) employed the SRC for SA, but these studies did not provide any specific justification for the choice of the SRC.”
ResultApplication of global sensitivity analysis of model output to building thermal simulations
Mara, T. A., & Tarantola, S. (2008) · Building Simulation · doi:10.1007/s12273-008-8129-5 · Cited by 144 · cited 3×
“In this paper, the Monte Carlo-based SA consists of five major steps as follows (Mara and Tarantola 2008): - Select the model to perform SA; - Identify simulation inputs of the model that should be included in the SA and the probability distribution functions of these variables; - Generate a sample…”
MethodInfluentialCosenza, A., Mannina, G., Vanrolleghem, P. A., & Neumann, M. B. (2013) · Environmental Modelling & Software · doi:10.1016/j.envsoft.2013.07.009 · Cited by 134 · cited 1×
“We observe that several SA studies employed the LHS method to generate input samples (Kotek et al. 2007; Hopfe Hensen 2011, Cosenza et al. 2013).”
MethodEldred, M., Vigil, D. M., Dalbey, K., Bohnhoff, W., Adams, B., Swiler, L. P., Lefantzi, S., Hough, P., & Eddy, J. (2011) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1031910 · Cited by 104
Kämpf, J. H., Wetter, M., & Robinson, D. (2010) · Journal of Building Performance Simulation · doi:10.1080/19401490903494597 · Cited by 103 · cited 2×
“Many studies have indicated that building simulation outputs are generally nonlinear, multimodal, discontinuous (Nguyen et al. 2014; Kampf et al. 2010), thus non-differentiable”
BackgroundWainwright, H. M., Finsterle, S. A., Zhou, Q., & Birkhölzer, J. (2013) · International journal of greenhouse gas control · doi:10.1016/j.ijggc.2013.05.007 · Cited by 98 · cited 3×
“…the literature that used or supported the Sobol method as the reference method (Saltelli and Bolado 1998; Ridolfi 2013; Massmann and Holzmann 2012; Wainwright et al. 2013; Confalonieri et al. 2010; Campolongo et al. 2007; Yang 2011), the Sobol method was considered the reference method for…”
MethodResultSandia National Laboratories (SNL), A., Adams, B., (NNSA), U. N. N. S. A., Ebeida, M., Eldred, M., Stephens, J. D., Swiler, L., Stephens, J., Vigil, D. M., Wildey, T. M., et al. (2014) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1177077 · Cited by 98
Nguyen, A. T., & Reiter, S. (2013) · Journal of Building Performance Simulation · doi:10.1080/19401493.2013.770067 · Cited by 78 · cited 2×
“The implementation of this comfort model into EnergyPlus was carefully described in (Nguyen and Reiter 2014; Nguyen 2013).”
MethodSelf-citationOptimisation Stories: The Impact of Building Information Modelling on Contemporary Design Practice
Garber, R. (2009) · Architectural Design · doi:10.1002/ad.842 · Cited by 73 · cited 2×
“reducing energy consumption, decreasing environmental impacts or improving indoor thermal environment (Garber 2009).”
BackgroundFrey, H. C., Mokhtari, A., & Danish, T. (2003) · Cited by 66
Massmann, C., & Holzmann, H. (2012) · Journal of Hydrology · doi:10.1016/j.jhydrol.2012.09.026 · Cited by 52 · cited 2×
“…on many studies found from the literature that used or supported the Sobol method as the reference method (Saltelli and Bolado 1998; Ridolfi 2013; Massmann and Holzmann 2012; Wainwright et al. 2013; Confalonieri et al. 2010; Campolongo et al. 2007; Yang 2011), the Sobol method was considered the…”
MethodSustainable housing in Vietnam: Climate responsive design strategies to optimize thermal comfort
Nguyen, A. T. (2013) · Cited by 39
Self-citation
Cited by
Life Cycle Assessment of building stocks from urban to transnational scales: A review
Mastrucci, A., Marvuglia, A., Leopold, U., & Benetto, E. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.060 · Cited by 191
Co-simulating a greenhouse in a building to quantify co-benefits of different coupled configurations
Jans-Singh, M., Ward, R., & Choudhary, R. (2021) · Journal of Building Performance Simulation · doi:10.1080/19401493.2021.1908426 · Cited by 22
“Sensitivity analysis (SA) is the ideal mechanism to do so, and has been applied extensively in BESmodelling (Tian 2013; Nguyen and Reiter 2015; Menberg, Heo, and Choudhary 2016).”
Method
Metadata
- Authors
- Nguyen, A.-T., & Reiter, S.
- Venue
- Building Simulation
- Published
- 2015-07-14
- Volume
- 8
- Issue
- 6
- Pages
- 651-664
- ISSN
- 1996-3599 (ISSN-L)
- 1996-8744
- OpenAlex
- W2140513970
- Cited by
- 164
- References
- 38
- FWCI
- 15.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.