The DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Impact of Donor Arm Cleaning with Different Aseptic Solutions for Prevention of Contamination in Blood Bags
Open accessAbstract
Transfusion associated sepsis cases are encountered occasionally and bacterial transmission remains the major cause. The goal of our study was to compare the efficacy of disinfectants in phlebotomy site preparation. After selection of donor the antecubital fossa area of the arm was disinfected with different types of disinfectants namely sprit (70% isopropyl alcohol), povidone iodine (0.5% w/v available iodine in distilled water), savlon (1.5% v/v chlorhexidine gluconate solution and 3.0% cetrimide solution) and combination of sprit and povidone iodine. Swabs were collected from 20 donors using a sterile forceps, after cleaning with different antiseptic solutions. Swab was streaked on blood agar plate aseptically and the plate was incubated at 37°C for 24 h. Colonies were counted and a single colony was re-cultured by growing on nutrient and Mac-Conkey agar. The biochemical characteristics were determined by performing Gram staining, Motility, Catalase and Oxidase tests. The mean values of colonies were significantly higher with savlon compared to other three solutions. The difference was statistically significant by "t" test (t values 1.7-3.0; P < 0.05). Staphylococcus epidermidis, Staphylococcus sp., Streptococcus sp., Micrococcus sp., Bacillus megaterium and Bacillus cereus were the organisms identified. After completion of bleeding, samples from the bag were aseptically inoculated in aerobic and anaerobic culture bottles to be tested on BacT/Alert system. The bag containing donor's blood did not show any contamination when three cleanings were carried out using sprit, povidone iodine and spirit respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Contamination of blood, by the normal flora of skin, during the blood collection procedure has been demonstrated to occur if the venepuncture site has not been properly cleaned [68], [69].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Blood Product-Associated Bacterial Sepsis
Goldman, M., & Blajchman, M. A. (1991) · Transfusion Medicine Reviews · doi:10.1016/s0887-7963(91)70194-6 · Cited by 242
Burrows, W. (1973) · Andalas University Repository (Andalas University) · Cited by 177
de Korte, D., Marcelis, J. H., Verhoeven, A. J., & Soeterboek, A. M. (2002) · Vox Sanguinis · doi:10.1046/j.1423-0410.2002.00189.x · Cited by 149
An Introduction to Microbiology
(1972) · Elsevier eBooks · doi:10.1016/c2013-0-06347-5 · Cited by 125
Larsen, C. P., Ezligini, F., Hermansen, N. O., & Kjeldsen‐Kragh, J. (2005) · Vox Sanguinis · doi:10.1111/j.1423-0410.2005.00596.x · Cited by 118
McDonald, C. P., Roy, A., Mahajan, P., Smith, R., Charlett, A., & Barbara, J. A. J. (2004) · Vox Sanguinis · doi:10.1111/j.0042-9007.2004.00404.x · Cited by 111
Evaluation of donor arm disinfection techniques
McDonald, C. P., Lowe, P., Roy, A., Robbins, S., Hartley, S., Harrison, J. F., Slopecki, A., Verlander, N. Q., & Barbara, J. A. J. (2001) · Vox Sanguinis · doi:10.1046/j.1423-0410.2001.00029.x · Cited by 97
Evaluation of donor skin disinfection methods
Goldman, M., Roy, G., Fréchette, N., Décary, F., Massicotte, L., & Delage, G. (1997) · Transfusion · doi:10.1046/j.1537-2995.1997.37397240214.x · Cited by 93
Kango, N. (2009) · Cited by 70
Bacterial contamination in platelet concentrates
Pietersz, R. N. I., Reesink, H. W., Panzer, S., Oknaian, S., Kuperman, S. L., Gabriel, C., Rapaille, A., Lambermont, M., Deneys, V., Sondag, D., et al. (2014) · Vox Sanguinis · doi:10.1111/vox.12098 · Cited by 67
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Joint EFLM-COLABIOCLI recommendation for venous blood sampling
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Annales de biologie clinique · doi:10.1684/abc.2019.1419 · Cited by 36
Arghittu, A., Dettori, M., Deriu, G. M., Soddu, S., Manca, P. C., Carboni, A. A., Collu, I., Palmieri, A., Deiana, G., Azara, A., et al. (2022) · Healthcare · doi:10.3390/healthcare10050845 · Cited by 9
Mehdaoui, F. E., Benajiba, M., Boulahdid, S., Hattimy, F. E., Soulaymani, A., & Alami, R. (2020) · Transfusion Medicine · doi:10.1111/tme.12704 · Cited by 5
Wspólne zalecenia EFLM-COLABIOCLI dotyczące pobierania krwi żylnej
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Diagnostyka Laboratoryjna · doi:10.5604/01.3001.0013.7785 · Cited by 2
Effect of donor arm washing on microbial growth at phlebotomy site in first time blood donors
(2018) · Hematology & Transfusion International Journal · doi:10.15406/htij.2018.06.00188 · Cited by 2
Rafiee, M. H., Kafiabad, S. A., Maghsudlu, M., Moradi, M., & Jalili, L. (2020) · Transfusion Clinique et Biologique · doi:10.1016/j.tracli.2020.01.005 · Cited by 2
Sánchez-Guzmán, M. D. J., Loyola-Cruz, M. Á., López-Ornelas, A., Cruz-Cruz, C., Durán-Manuel, E. M., & Bello–López, J. M. (2023) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2023.103854 · Cited by 1
Ganesan, N., Shanmugham, H., & Kumar, P. N. (2019) · Saudi Journal of Pathology and Microbiology · doi:10.36348/sjpm.2019.v04i09.008
Joint EFLM-COLABIOCLI recommendation for venous blood sampling - v 1.1, June 2018
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2024) · Revista română de medicină de laborator · doi:10.2478/rrlm-2024-0004
Gatt, N., Gialanze, J. P., Spiteri, N., & Zammit, V. (2024) · Microbiology Research Journal International · doi:10.9734/mrji/2024/v34i121521
Metadata
- Authors
- Patel, T. G., Shukla, R. V., & Gupte, S. C.
- Corresponding author
- Gupte, Snehalata C.
- Venue
- Indian Journal of Hematology and Blood Transfusion
- Published
- 2012-01-31
- Volume
- 29
- Issue
- 1
- Pages
- 17-20
- ISSN
- 0971-4502 (ISSN-L)
- 0974-0449
- PMC
- PMC3572260
- OpenAlex
- W2050539385
- Semantic Scholar
- 6f3c0a0453922052c985c22ad4553794c824afff
- Cited by
- 11
- References
- 19
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 1 · 2020: 2 · 2019: 3 · 2018: 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Indian Journal of Hematology and Blood Transfusion (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Surgery › Surgical site infection prevention
- Health Sciences › Medicine › Hematology › Blood donation and transfusion practices
- Keywords
- antiseptic solutions, transfusion-associated sepsis, bacterial transmission, isopropanol, povidone-iodine, chlorhexidine gluconate, cetrimide, Staphylococcus epidermidis, Bacillus cereus, Bacillus megaterium
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review