The DOI matches its Crossref record.
Patient preparation for cardiac fluorine-18 fluorodeoxyglucose positron emission tomography imaging of inflammation
Open accessAbstract
Although the number of clinical applications for fluorine-18 fluorodeoxyglucose (18F-FDG) cardiac positron emission tomography (PET) has continued to grow, there remains a lack of consensus regarding the ideal method of suppressing normal myocardial glucose utilization for image optimization. This review describes various patient preparation protocols that have been used as well as the success rates achieved in different studies. Collectively, the available literature supports using a high-fat, no-carbohydrate diet for at least two meals with a fast of 4-12 hours prior to 18F-FDG PET imaging and suggests that isolated fasting for less than 12 hours and supplementation with food or drink just prior to imaging should be avoided. Each institution should adopt a protocol and continuously monitor its effectiveness with a goal to achieve adequate myocardial suppression in greater than 80% of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chareonthaitawee, P., Beanlands, R. S., Chen, W., Dorbala, S., Miller, E. J., Murthy, V. L., Birnie, D. H., Chen, E. S., Cooper, L. T., Tung, R. H., et al. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.196287 · Cited by 300
Self-citationVita, T., Okada, D. R., Veillet-Chowdhury, M., Bravo, P. E., Mullins, E., Hulten, E., Agrawal, M., Madan, R., Taqueti, V. R., Steigner, M., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007030 · Cited by 275
Self-citationCardiac sarcoidosis: state-of-the-art review
Kouranos, V., & Sharma, R. (2021) · Heart · doi:10.1136/heartjnl-2019-316442 · Cited by 259
Cheng, R. K., Kittleson, M. M., Beavers, C. J., Birnie, D. H., Blankstein, R., Bravo, P. E., Gilotra, N. A., Judson, M. A., Patton, K. K., Rose-Bovino, L., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001240 · Cited by 259
Self-citationChareonthaitawee, P., Beanlands, R. S., Chen, W., Dorbala, S., Miller, E. J., Murthy, V. L., Birnie, D. H., Chen, E. S., Cooper, L. T., Tung, R. H., et al. (2017) · Journal of Nuclear Cardiology · doi:10.1007/s12350-017-0978-9 · Cited by 254
Self-citation
Metadata
- Authors
- Osborne, M. T., Hulten, E. A., Murthy, V. L., Skali, H., Taqueti, V. R., Dorbala, S., DiCarli, M. F., & Blankstein, R.
- Venue
- Journal of Nuclear Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 24
- Issue
- 1
- Pages
- 86-99
- ISSN
- 1071-3581 (ISSN-L)
- OpenAlex
- W2414343713
- Cited by
- 235
- References
- 0
- FWCI
- 16.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient preparation for cardiac fluorine-18 fluorodeoxyglucose positron emission tomography imaging of inflammation. https://app.cochat.ai/papers/10.1007/s12350-016-0502-7
- The paper
- Osborne, M. T., Hulten, E. A., Murthy, V. L., Skali, H., Taqueti, V. R., Dorbala, S., DiCarli, M. F., & Blankstein, R. (2017). Patient preparation for cardiac fluorine-18 fluorodeoxyglucose positron emission tomography imaging of inflammation. Journal of Nuclear Cardiology. https://doi.org/10.1007/s12350-016-0502-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.