CoChat

Good practice for radiological reporting. Guidelines from the European Society of Radiology (ESR)

Open access
European Society of Radiology (ESR) · 2011 · Insights into Imaging
Cited by 174

The DOI matches its Crossref record.

Abstract

The views of the European Society of Radiology concerning what constitutes a good radiological report are outlined in this article. Some pertinent literature is reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13244-011-0066-7

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
European Society of Radiology (ESR)
Venue
Insights into Imaging
Published
2011-02-06
Volume
2
Issue
2
Pages
93-96
ISSN
1869-4101 (ISSN-L)
OpenAlex
W4233624763
Cited by
174
References
0
FWCI
3.91
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Good practice for radiological reporting. Guidelines from the European Society of Radiology (ESR). https://app.cochat.ai/papers/10.1007/s13244-011-0066-7
The paper
European Society of Radiology (ESR). (2011). Good practice for radiological reporting. Guidelines from the European Society of Radiology (ESR). Insights into Imaging. https://doi.org/10.1007/s13244-011-0066-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.