ExMS: Data Analysis for HX-MS Experiments
Open accessThe DOI matches its Crossref record.
Abstract
A previous paper considered the problems that presently limit the hydrogen exchange-mass spectrometry (HX-MS) method for studying the biophysical and functional properties of proteins. Many of these problems can be overcome by obtaining and analyzing hundreds of sequentially overlapping peptide fragments that cover the protein many times over (Mayne et al. J. Am. Soc. Mass Spectrom. 2011: 10.1007/s13361-011-0235-4). This paper describes a computer program called ExMS that furthers this advance by making it possible to efficiently process crowded mass spectra and definitively identify and characterize these many peptide fragments. ExMS automatically scans through high resolution MS data to find the individual isotopic peaks and isotopic envelopes of a list of peptides previously identified by MS/MS. It performs a number of tests to ensure correct identification in spite of peptide overlap in both chromatographic and mass spectrometric dimensions and possible multi-modal envelopes due to static or dynamic structural heterogeneity or HX EX1 behavior. The program can automatically process data from many sequential HX time points with no operator intervention at the rate of ~2 sec per peptide per HX time point using desktop computer equipment, but it also provides for rapid manual checking and decision when ambiguity exists. Additional subroutines can provide a step by step report of performance at each test along the way and parameter adjustment, deconvolute isotopic envelopes, and plot the time course of single and multi-modal H-D exchange. The program will be available on an open source basis at: http://HX2.med.upenn.edu/download.html.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogen Tunneling Links Protein Dynamics to Enzyme Catalysis
Klinman, J. P., & Kohen, A. (2013) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-051710-133623 · Cited by 388
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
HDX Workbench: Software for the Analysis of H/D Exchange MS Data
Pascal, B. D., Willis, S., Lauer, J. L., Landgraf, R. R., West, G. M., Marciano, D., Novick, S., Goswami, D., Chalmers, M. J., & Griffin, P. R. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0419-6 · Cited by 293
Liu, X. R., Zhang, M. M., & Gross, M. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00815 · Cited by 242
Langelier, M.-F., Zandarashvili, L., Aguiar, P. M., Black, B. E., & Pascal, J. M. (2018) · Nature Communications · doi:10.1038/s41467-018-03234-8 · Cited by 227
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“…to monitor residue-specific deuterium uptake (Zehl et al , 2008), and sophisticated software tools for peptide mapping, data analysis, and structural interpretation (Slysz et al , 2009; Kan et al , 2011; Pascal et al , 2012; Rey et al , 2014) — have additionally streamlined the HDX-MS workflow.”
CENP-C reshapes and stabilizes CENP-A nucleosomes at the centromere
Falk, S. J., Guo, L. Y., Sekulic, N., Smoak, E. M., Mani, T., Logsdon, G. A., Gupta, K., Jansen, L. E. T., Van Duyne, G. D., Vinogradov, S. A., et al. (2015) · Science · doi:10.1126/science.1259308 · Cited by 212
Minimizing Back Exchange in the Hydrogen Exchange-Mass Spectrometry Experiment
Walters, B. T., Ricciuti, A., Mayne, L., & Englander, S. W. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0476-x · Cited by 182
“The combination of previously described methods for producing [31] and analyzing [32] many peptide fragments together with the ability to largely negate deleterious back exchange moves toward the goal of obtaining ultimate amino acid structural resolution for HX MS analysis.”
Self-citationStepwise protein folding at near amino acid resolution by hydrogen exchange and mass spectrometry
Hu, W., Walters, B. T., Kan, Z.-Y., Mayne, L., Rosen, L. E., Marqusee, S., & Englander, S. W. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1305887110 · Cited by 172
“J Am Soc Mass Spectrom 23(12):2132–2139.”
BackgroundMethodInfluentialSelf-citationAnalysis of Overlapped and Noisy Hydrogen/Deuterium Exchange Mass Spectra
Guttman, M., Weis, D. D., Engen, J. R., & Lee, K. K. (2013) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-013-0727-5 · Cited by 169
“Deconvolution of such bimodal behavior within the exchange profile is critical for accurate interpretation of HDX data [15], but this has only recently started to become incorporated into automated HDX analysis software [9, 10].”
BackgroundMethodInfluentialKoenig, P., Lee, C. V., Walters, B. T., Janakiraman, V., Stinson, J., Patapoff, T. W., & Fuh, G. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1613231114 · Cited by 107
Chetty, P. S., Mayne, L., Lund-Katz, S., Englander, S. W., & Phillips, M. C. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1617523114 · Cited by 58
Self-citation
Metadata
- Authors
- Kan, Z.-Y., Mayne, L., Sevugan Chetty, P., & Englander, S. W.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-09-15
- Volume
- 22
- Issue
- 11
- Pages
- 1906-15
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2023505696
- Cited by
- 126
- References
- 0
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.