Charge Detection Mass Spectrometry with Resolved Charge States
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Charge detection mass spectrometry (CDMS) measurements have been performed for cytochrome c and alcohol dehydrogenase (ADH) monomer using a modified cone trap incorporating a cryogenically cooled JFET. Cooling the JFET increases its transconductance and lowers thermal noise, improving the signal to noise (S/N) ratio. Single ions with as few as 9 elementary charges (e) have been detected. According to simulations, the detection efficiency for ions with a charge of 13 e is 75%, and for charges above 13 e the detection efficiency rapidly approaches 95%. With the low limit of detection achieved here, adjacent charge states are easily resolved in the m/z spectrum, so the accuracy and precision of the image charge measurements can be directly evaluated by comparing the measured image charge to the charge deduced from the m/z spectrum. For ADH monomer ions with 32 to 43 charges, the root mean square deviation of the measured image charge is around 2.2 e. Ions were trapped for over 1500 cycles. The number of cycles detected appears to be limited mainly by collisions with the background gas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766 · cited 1×
“T here has been growing interest in using mass spectrometry to investigate protein complexes [1–3] but their high masses present a challenge.”
Background
Cited by
Integrative structure and functional anatomy of a nuclear pore complex
Kim, S. J., Fernandez-Martinez, J., Nudelman, I., Shi, Y., Zhang, W., Raveh, B., Herricks, T., Slaughter, B. D., Hogan, J. A., Upla, P., et al. (2018) · Nature · doi:10.1038/nature26003 · Cited by 490
Self-citationA Critical Review of Bottom-Up Proteomics: The Good, the Bad, and the Future of This Field
Dupree, E. J., Jayathirtha, M., Yorkey, H., Mihasan, M., Petre, B. A., & Darie, C. C. (2020) · Proteomes · doi:10.3390/proteomes8030014 · Cited by 353
Triboelectric nanogenerators for sensitive nano-coulomb molecular mass spectrometry
Li, A., Zi, Y., Guo, H., Wang, Z. L., & Fernández, F. M. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.17 · Cited by 324
Resolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
Self-citationSTORI Plots Enable Accurate Tracking of Individual Ion Signals
Kafader, J. O., Beu, S. C., Early, B. P., Melani, R. D., Durbin, K. R., Zabrouskov, V., Makarov, A. A., Maze, J. T., Shinholt, D. L., Yip, P. F., et al. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02309-0 · Cited by 85
“Due to limited detector sensitivity, this has been applied primarily to large molecules with tens to thousands of charges, but improvements have made this method applicable to ions with less than 10 elementary charges[10, 11].”
Metadata
- Authors
- Contino, N. C., Pierson, E. E., Keifer, D. Z., & Jarrold, M. F.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-11-30
- Volume
- 24
- Issue
- 1
- Pages
- 101-108
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2074740617
- Cited by
- 100
- References
- 2
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Charge Detection Mass Spectrometry with Resolved Charge States. https://app.cochat.ai/papers/10.1007/s13361-012-0525-5
- The paper
- Contino, N. C., Pierson, E. E., Keifer, D. Z., & Jarrold, M. F. (2013). Charge Detection Mass Spectrometry with Resolved Charge States. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-012-0525-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.