CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry
Open accessThe DOI matches its Crossref record.
Abstract
The emergence of argon-based gas cluster ion beams for SIMS experiments opens new possibilities for molecular depth profiling and 3D chemical imaging. These beams generally leave less surface chemical damage and yield mass spectra with reduced fragmentation compared with smaller cluster projectiles. For nanoscale bioimaging applications, however, limited sensitivity due to low ionization probability and technical challenges of beam focusing remain problematic. The use of gas cluster ion beams based upon systems other than argon offer an opportunity to resolve these difficulties. Here we report on the prospects of employing CO2 as a simple alternative to argon. Ionization efficiency, chemical damage, sputter rate, and beam focus are investigated on model compounds using a series of CO2 and Ar cluster projectiles (cluster size 1000-5000) with the same mass. The results show that the two projectiles are very similar in each of these aspects. Computer simulations comparing the impact of Ar2000 and (CO2)2000 on an organic target also confirm that the CO2 molecules in the cluster projectile remain intact, acting as a single particle of m/z 44. The imaging resolution employing CO2 cluster projectiles is improved by more than a factor of two. The advantage of CO2 versus Ar is also related to the increased stability which, in addition, facilitates the operation of the gas cluster ion beams (GCIB) system at lower backing pressure. Graphical Abstract ᅟ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass Spectrometry Imaging: A Review of Emerging Advancements and Future Insights
Buchberger, A. R., DeLaney, K., Johnson, J., & Li, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04733 · Cited by 1,029
Taylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Porta Siegel, T., Hamm, G., Bunch, J., Cappell, J., Fletcher, J. S., & Schwamborn, K. (2018) · Molecular Imaging and Biology · doi:10.1007/s11307-018-1267-y · Cited by 187
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Selective Adsorption of CO 2 over N 2 on Graphene: Insights from First-Principles Calculations
Faghihnasiri, M., & Branicio, P. S. (2025) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5c00105 · Cited by 17
Metadata
- Authors
- Tian, H., Maciążek, D., Postawa, Z., Garrison, B. J., & Winograd, N.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-06-20
- Volume
- 27
- Issue
- 9
- Pages
- 1476-1482
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2463368692
- Cited by
- 55
- References
- 0
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry. https://app.cochat.ai/papers/10.1007/s13361-016-1423-z
- The paper
- Tian, H., Maciążek, D., Postawa, Z., Garrison, B. J., & Winograd, N. (2016). CO2 Cluster Ion Beam, an Alternative Projectile for Secondary Ion Mass Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-016-1423-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.