The sTOF, a Favorable Geometry for a Time-of-Flight Analyzer
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A new geometry for the flight region in a time-of-flight mass spectrometer is presented. It consists of two opposing electrostatic sectors of about 255° each and straight sections with a length appropriate to the turns. The resulting geometry folds into a compact space. The first-order aberrations for position, angle, and energy are all zero. The transverse focusing properties are also excellent. For an energetic, high-divergence ion source such as laser ablation, the sTOF has higher resolution and ion transmission than a reflectron of similar physical size. Graphical Abstract ᅟ.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
(1967) · Elsevier eBooks · doi:10.1016/b978-0-12-636901-4.x5001-9 · Cited by 372
Beavis, R. C., & Chait, B. T. (1991) · Chemical Physics Letters · doi:10.1016/0009-2614(91)90384-l · Cited by 269 · cited 1×
“Ions produced from matrix-assisted laser desorption ionization (MALDI) can have translational energies exceeding several electron volts [19].”
BackgroundMultiple-focusing time-of-flight mass spectrometers Part II. TOFMS with equal energy acceleration
Poschenrieder, W. P. (1972) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(72)80020-2 · Cited by 249
Particle Analysis by Laser Mass Spectrometry WB-57F Instrument Overview
Thomson, D. S., Schein, M. E., & Murphy, D. M. (2000) · Aerosol Science and Technology · doi:10.1080/027868200410903 · Cited by 143 · cited 2×
“The particle analysis by laser mass spectrometry (PALMS) instrument obtains mass spectra of single particles in the atmosphere with laser ionization and a time-of-flight mass spectrometer [2].”
MethodSelf-citationMulti‐turn time‐of‐flight mass spectrometers with electrostatic sectors
Toyoda, M., Okumura, D., Ishihara, M., & Katakuse, I. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.546 · Cited by 106 · cited 1×
“Such focal points allow elegant designs that are amenable to multi-turn operation whereby ions complete multiple laps through the same sectors [13, 14].”
BackgroundRiedo, A., Bieler, A., Neuland, M. B., Tulej, M., & Wurz, P. (2012) · Journal of Mass Spectrometry · doi:10.1002/jms.3104 · Cited by 101 · cited 1×
“Gridless reflectron designs with a lens integrated into the front of the reflectron can produce excellent spectra from a miniature instrument [20].”
BackgroundA novel principle for an ion mirror design in time-of-flight mass spectrometry
Scherer, S., Altwegg, K., Balsiger, H., Fischer, J., Jäckel, A., Korth, A., Mildner, M., Piazza, D., Rème, H., & Wurz, P. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.01.025 · Cited by 74 · cited 1×
“Although it is possible to build reflectrons without grids [8, 9], most high-resolution reflectrons have them.”
BackgroundRiedo, A., Bieler, A., Neuland, M. B., Tulej, M., & Wurz, P. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3157 · Cited by 66
Ion optics for time-of-flight mass spectrometers with multiple symmetry
Sakurai, T., Matsuo, T., & Matsuda, H. (1985) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(85)80030-6 · Cited by 55 · cited 3×
“Somewhat surprisingly, the advantages of this sector angle are not stated in some of the classic papers on TOF sectors [3, 11].”
BackgroundMethodInfluentialElectrostatic Analyzer with Variable Focal Length
Matsuda, H. (1961) · Review of Scientific Instruments · doi:10.1063/1.1717529 · Cited by 52
Research works printed but not linked: 2
- Mamyrin BA, 1979, Sov. Phys. JETP., 49, 762
- Grivet, P., Bernard, M.Y., Bertein, F., Castaing, R., Gauzit, M., Septier, A: (2nd Engl. ed.) Pergamon Press: Oxford (1972)
Cited by
Metals from spacecraft reentry in stratospheric aerosol particles
Murphy, D. M., Abou-Ghanem, M., Cziczo, D. J., Froyd, K. D., Jacquot, J., Lawler, M. J., Maloney, C., Plane, J. M. C., Ross, M. N., Schill, G. P., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2313374120 · Cited by 107
Self-citationCheng, Y.-H., Cheung, H. Y. F., Tam, T. S.-C., Lok, C., Sun, H., & Ng, K. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.057 · Cited by 27
A new airborne single particle mass spectrometer: PALMS-NG
Jacquot, J., Shen, X., Abou‐Ghanem, M., Froyd, K. D., Lawler, M. J., Schill, G. P., Slovacek, K., Thomson, D. S., Cziczo, D. J., & Murphy, D. M. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2331549 · Cited by 22
“Since then, several other SPMSs have been designed or adapted to research aircraft: A-ATOFMS (Pratt et al. 2009), SPLAT II (Zelenyuk et al. 2009), ALABAMA (Brands et al. 2011), miniSPLAT (Zelenyuk et al. 2015), and ERICA (H € unig et al. 2022).”
InfluentialSelf-citationThe LMS-GT instrument – a new perspective for quantification with the LIMS-TOF measurement technique
Wiesendanger, R., Grimaudo, V., Tulej, M., Riedo, A., Lukmanov, R., Ligterink, N. F. W., Fausch, R., Shea, H. R., & Wurz, P. (2019) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c9ja00235a · Cited by 22
Ab Initio Computation of Energy Deposition During Electron Ionization of Molecules
Irikura, K. K. (2017) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.7b07993 · Cited by 13
Metadata
- Authors
- Murphy, D. M.
- Affiliations
- National Oceanic and Atmospheric Administration (US)
- Corresponding author
- Murphy, Daniel M.
- ORCID
- Murphy, Daniel M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-11-09
- Volume
- 28
- Issue
- 2
- Pages
- 242-246
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2555105220
- Cited by
- 9
- References
- 19
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2021: 1 · 2019: 2 · 2017: 2
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Update notices
- correction (2018-03-05)
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Keywords
- time-of-flight mass spectrometer, transverse focusing, laser ablation ion source, ion transmission, mass resolution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The sTOF, a Favorable Geometry for a Time-of-Flight Analyzer. https://app.cochat.ai/papers/10.1007/s13361-016-1518-6
- The paper
- Murphy, D. M. (2017). The sTOF, a Favorable Geometry for a Time-of-Flight Analyzer. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-016-1518-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.