Cited by 44Mass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

Ion-Ion Proton Transfer and Parallel Ion Parking for the Analysis of Mixtures of Intact Proteins on a Modified Orbitrap Mass Analyzer

Open access
Ugrin, Scott A., English, A. Michelle, Syka, John E. P., Bai, Dina L., Anderson, Lissa C., Shabanowitz, Jeffrey, Hunt, Donald F.·2019·Journal of the American Society for Mass Spectrometry

Abstract

We have enabled parallel ion parking on a modified Orbitrap Elite™ as a way to control ion-ion proton transfer reactions via selective activation of a range of ions. The result is the concentration of the majority of ion current from multiple charge states of each precursor proteoform into a single charge state, maximizing signal intensity and increasing effective sensitivity compared to conventional MS1 spectra. These techniques were applied in an on-line HPLC, data-dependent MS/MS analysis of intact E. coli ribosomal proteins with HCD fragmentation. With one injection, all but two ribosomal proteins were selected for fragmentation and subsequently identified. The techniques described facilitate rapid identification of intact proteins in complex mixtures and an enhanced ability to observe proteins of low abundance.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13361-019-02290-8

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 26 · Cited by 44

Authors
Ugrin, S. A., English, A. M., Syka, J. E. P., Bai, D. L., Anderson, L. C., Shabanowitz, J., & Hunt, D. F.
Affiliations
  • University of Virginia (US)
  • Thermo Fisher Scientific (United States) (US)
  • National High Magnetic Field Laboratory (US)
Corresponding author
Hunt, Donald F.
Venue
Journal of the American Society for Mass Spectrometry
Published
2019-08-07
Volume
30
Issue
10
Pages
2163-2173
ISSN
1044-0305 (ISSN-L)
OpenAlex
W2966700924
Cited by
44
References
26
Citations by year
2026: 4 · 2025: 5 · 2024: 7 · 2023: 4 · 2022: 8 · 2021: 6 · 2020: 6 · 2019: 4
FWCI
2.40
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Society for Mass Spectrometry (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation (DMR-1157490, DMR-1644779)
  • National Institute of General Medical Sciences (GM037537)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
top-down proteomics, HCD fragmentation, ribosomal proteins, Escherichia coli, low-abundance proteins, proteoforms, HPLC-MS/MS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review