Cited by 165Building Energy and Comfort OptimizationSolar Energy Systems and TechnologiesBuilding energy efficiency and sustainability

Effect of building shape, orientation, window to wall ratios and zones on energy efficiency and thermal comfort of naturally ventilated houses in tropical climate

Open access
Pathirana, Shakila, Rodrigo, Asanka, Halwatura, Rangika·2019·International Journal of Energy and Environmental Engineering

Abstract

This paper examines the effect of building shape, zones, orientation and window to wall ratio (WWR) on the lighting energy requirement and the thermal comfort in the naturally ventilated houses in tropical climate. The lighting electricity and the adaptive thermal discomfort hours (ASHRAE 55 80% acceptability) of 300 different models of two-storey houses were obtained using Design Builder simulation software. The models were developed for three building shapes (square, rectangle and L-shaped) and the orientation of each model was changed for 24 orientations and four window to wall ratios. Results indicate that the rectangular shape with staircase positioned in the middle of the house will provide higher thermal comfort for WWR of 20 and for other WWRs the L-shaped models provide higher thermal comfort when the staircase is positioned at the short corner or middle. The square-shaped houses with staircase at the middle have the highest lighting electricity and the L shape has the lowest lighting electricity. Further, WWR changes the thermal comfort by 20–55% and the percentage change in lighting electricity due to WWR is only 1.5–9.5%. Therefore, thermal comfort should receive more attention in deciding the WWR. Moreover, the results show an effect when the zone sizes and location change.

Integrity signals

Registry

Crossref · 10.1007/s40095-018-0295-3

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Pathirana, S., Rodrigo, A., & Halwatura, R.
Affiliations
University of Moratuwa (LK)
Corresponding author
Pathirana, Shakila
Venue
International Journal of Energy and Environmental Engineering
Published
2019-01-03
Volume
10
Issue
1
Pages
107-120
ISSN
  • 2008-9163 (ISSN-L)
  • 2251-6832
OpenAlex
W2907052696
Cited by
165
References
0
Citations by year
2026: 15 · 2025: 27 · 2024: 33 · 2023: 26 · 2022: 22 · 2021: 27 · 2020: 14 · 2019: 1
FWCI
10.72
Type
journal article
Language
en
Open access
Locations
  • International journal of energy and environmental engineering (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
University of Moratuwa (SRC/ST/2017/42)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Solar Energy Systems and Technologies
  • Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
Keywords
building geometry, building orientation, window-to-wall ratio, thermal comfort, lighting energy, adaptive thermal comfort, ASHRAE Standard 55, thermal zones, tropical climate, two-story houses, energy efficiency

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›