The DOI matches its Crossref record; 26 of the 29 references it cites were found in a registry or an index.
Horizontal active vibration isolator (HAVI) using electromagnetic planar actuator (EPA)
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The vertical force was utilized to adjust the natural frequency of the isolator, whereas the horizontal force was applied to reduce the horizontal disturbance of the isolator.”
From Invited Review: Recent developments in vibration control of building and bridge structures (2017) · cites this paper as [109]
The cited source says what the claim attributes to it.
In the citing paper
“Pham and Ahn [109] presented Horizontal Active Vibration Isolator (HAVI) using forces of an EM Planar Actuator (EPA) in both vertical and horizontal directions.”
From Invited Review: Recent developments in vibration control of building and bridge structures (2017) · cites this paper as [109]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“To deal with this issue, researchers have proposed hybrid base isolation systems.”
From Invited Review: Recent developments in vibration control of building and bridge structures (2017) · cites this paper as [109]
Experimental — accuracy not yet measuredIn the citing paper
“The vertical force was utilized to adjust the natural frequency of the isolator, whereas the horizontal force was applied to reduce the horizontal disturbance of the isolator.”
From Invited Review: Recent developments in vibration control of building and bridge structures (2017) · cites this paper as [109]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of vibration analysis
Meirovitch, L. (1975) · Andalas University Repository (Andalas University) · Cited by 1,768
Vibration Control Using Semi-Active Force Generators
KARNOPP, D. C., Crosby, M. J., & Harwood, R. A. (1974) · Journal of Engineering for Industry · doi:10.1115/1.3438373 · Cited by 1,365 · cited 1×
“The characteristics of different kinds of active vibration isolators have been detailed by many researchers.(1-4) Simple horizontal vibration isolator with spring-damper-actuator is extended to the multi-degree-of-freedom (MDOF) isolators to satisfy demand of rejection the MDOF disturbance.”
Harris, C. M., Crede, C. E., & Trent, H. M. (1962) · Physics Today · doi:10.1063/1.3058391 · Cited by 1,023 · cited 2×
“(5) and (6) and verified with the EPA.”
Huang, X., Liu, X., Sun, J., Zhang, Z., & Hua, H. (2014) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2013.10.026 · Cited by 405 · cited 1×
“SDOF vibration isolators with FBC were studied in high-static and low-dynamic stiffness isolator systems.(11-15) On actuator for horizontal isolators, complex mechanism or large space is necessary since actuator has many limitations such as stroke, degree of freedom and capacity.”
Harris, C. M., & Crede, C. E. (1976) · UCLA Biblioteca de Ingenieria Civil · Cited by 332
(1972) · Journal of Sound and Vibration · doi:10.1016/0022-460x(72)90725-0 · Cited by 269
Linearizing control of magnetic suspension systems
Trumper, D. L., Olson, S. M., & Subrahmanyan, P. K. (1997) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.595924 · Cited by 264 · cited 1×
“Furthermore, a magnetic suspension was addressed with a linear controller providing satisfactory performance such as stability and disturbance rejection over a wide range of operating points.(21) Although 6 DOF EPAs were studied for compact MDOF motion control systems,(22-24) the EPA was hardly applied to the vibratio…”
An ultra-precision XY/spl theta//sub Z/ piezo-micropositioner. I. Design and analysis
Chang, S. H., Tseng, C. K., & Chien, H. C. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.775656 · Cited by 126
2008 IEEE International Symposium on Intelligent Control
(2008) · doi:10.1109/isic14195.2008 · Cited by 123
On the shock performance of a nonlinear vibration isolator with high-static-low-dynamic-stiffness
Tang, B., & Brennan, M. J. (2014) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2014.02.019 · Cited by 115 · cited 1×
“SDOF vibration isolators with FBC were studied in high-static and low-dynamic stiffness isolator systems.(11-15) On actuator for horizontal isolators, complex mechanism or large space is necessary since actuator has many limitations such as stroke, degree of freedom and capacity.”
A Newly Developed Linear Motor-Driven Aerostatic X-Y Planar Motion Table System for Nano-Machining
Shinno, H., Yoshioka, H., & Taniguchi, K. (2007) · CIRP Annals · doi:10.1016/j.cirp.2007.05.086 · Cited by 113
Tuning passive, semi-active, and fully active suspension systems
Miller, L. R. (2003) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.1988.194694 · Cited by 72 · cited 1×
“First, the single-degree-offreedom (SDOF) mechanisms consisted of mass-spring-damper is used widely for vibration isolators.(6-8) Disturbance from ground can be reduced significantly with very low stiffness.”
Optimal design of a QZS isolator using flexures for a wide range of payload
Kim, K.-R., You, Y.-H., & Ahn, H.-J. (2013) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-013-0120-0 · Cited by 47 · cited 1×
“SDOF vibration isolators with FBC were studied in high-static and low-dynamic stiffness isolator systems.(11-15) On actuator for horizontal isolators, complex mechanism or large space is necessary since actuator has many limitations such as stroke, degree of freedom and capacity.”
Self-citation2D hall sensor array for measuring the position of a magnet matrix
Ahn, H. J., & Kim, K. R. (2014) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-014-0017-0 · Cited by 34 · cited 4×
“Four hall sensor arrays are used to measure MDOF motion of the HAVI.25 The impulse disturbance rejection is investigated experimentally to verify effectiveness of the HAVI using the EPA.”
Self-citationMagnetic suspension techniques for precision motion control
Trumper, D. L. (1990) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 33
Control of Multi-Degree-of-Freedom planar actuators
van Lierop, C. M. M., Jansen, J. W., Damen, A. A. H., & van den Bosch, P. P. J. (2006) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cacsd-cca-isic.2006.4777034 · Cited by 31
Shin, K. (2014) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-014-0355-4 · Cited by 28 · cited 1×
“SDOF vibration isolators with FBC were studied in high-static and low-dynamic stiffness isolator systems.(11-15) On actuator for horizontal isolators, complex mechanism or large space is necessary since actuator has many limitations such as stroke, degree of freedom and capacity.”
Vibration Isolation: A Review, I. Sinusoidal and Random Excitations
Nelson, F. C. (1994) · Shock and Vibration · doi:10.1155/1994/576705 · Cited by 21
A nonlinear control of an QZS isolator with flexures based on a lyapunov function
Trung, P. V., Kim, K.-R., & Ahn, H.-J. (2013) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-013-0121-z · Cited by 16 · cited 1×
“SDOF vibration isolators with FBC were studied in high-static and low-dynamic stiffness isolator systems.(11-15) On actuator for horizontal isolators, complex mechanism or large space is necessary since actuator has many limitations such as stroke, degree of freedom and capacity.”
Self-citationA perspective on active machinery isolation
Watters, B. G., Coleman, R. B., Duckworth, G. L., & Berkman, E. F. (2003) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.1988.194691 · Cited by 16 · cited 1×
“The characteristics of different kinds of active vibration isolators have been detailed by many researchers.(1-4) Simple horizontal vibration isolator with spring-damper-actuator is extended to the multi-degree-of-freedom (MDOF) isolators to satisfy demand of rejection the MDOF disturbance.”
Six-axis position measurement system for levitated motion stages
Lü, X., Rao, N., & Usman, I.-U.-R. (2013) · CIRP Annals · doi:10.1016/j.cirp.2013.03.015 · Cited by 13
Design and control of a 6-DOF high-precision integrated positioner
Kim, W.-J., Hu, T., & Bhat, N. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1383839 · Cited by 10
ISOLATION AND ABSORPTION OF MACHINERY VIBRATION
Snowdon, J. C. (1976) · Defense Technical Information Center (DTIC) · Cited by 10
New electro-magnetic actuator for active vibration isolators
Hong, D., Hwang, H.-Y., Lee, M., Jo, Y.-K., Vu, D.-T., & Lee, D. (2015) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-015-0028-y · Cited by 7
Active isolation of periodic machinery vibration from resonant substructures
Jenkins, M. D., Nelson, P. A., & Elliott, S. J. (1991) · ePrints Soton (University of Southampton) · Cited by 4
Biological monitoring of environmental quality: The use of developmental instability
Freeman, D. C., Emlen, J. M., Graham, J. H., Hough, R. A., & Bannon, T. A. (1994) · Journal of Environmental Engineering · Cited by 1
Research works printed but not linked: 2
- Inman, D. J., “Engineering Vibration,” Prentice-Hall, 1996.
- Compter, J. C. and Frissen, P. C. M, “Electro-Dynamic Planar Actuator,” Proc. of Mechatronics, pp. 81–87, 2002.
Cited by
Invited Review: Recent developments in vibration control of building and bridge structures
Ghaedi, K., Ibrahim, Z., Adeli, H., & Javanmardi, A. (2017) · Journal of Vibroengineering · doi:10.21595/jve.2017.18900 · Cited by 146
“Pham and Ahn [109] presented Horizontal Active Vibration Isolator (HAVI) using forces of an EM Planar Actuator (EPA) in both vertical and horizontal directions.”
MethodRecent Advances in Hybrid Vibration-Control Systems
Stanikzai, M. H., Elias, S., & Chae, Y. (2022) · Practice Periodical on Structural Design and Construction · doi:10.1061/(asce)sc.1943-5576.0000685 · Cited by 66
Control of a hybrid active-passive vibration isolation system
Lee, J. H., Kim, H. Y., Kim, K. H., Kim, M. H., & Lee, S. W. (2017) · Journal of Mechanical Science and Technology · doi:10.1007/s12206-017-1112-2 · Cited by 32
The latest preload technology of machine tool spindles: A review
Lee, C.-M., Woo, W.-S., & Kim, D.-H. (2017) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-017-0195-0 · Cited by 17
“It is expected that this technology will become more important and valuable in the future considering the trend of modern machining technology demanding compact, high precision levels, and high speeds.(44-50) Moreover, it is necessary to grasp the trend of this technology accurately and to maintain a high level of int…”
BackgroundDesign of Magnetic Force Field for Trajectory Control of Levitated Diamagnetic Graphite
Kang, S.-M., Kim, J.-H., Pyo, J., Cho, J. H., & Kim, T. (2018) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-018-0036-3 · Cited by 17
Metadata
- Authors
- Pham, M.-N., & Ahn, H.-J.
- Affiliations
- Université du Québec à Montréal (CA)
- Soongsil University (KR)
- Corresponding author
- Ahn, Hyeong-Joon
- ORCID
- Ahn, Hyeong-Joon
- Venue
- International Journal of Precision Engineering and Manufacturing-Green Technology
- Published
- 2015-07
- Volume
- 2
- Issue
- 3
- Pages
- 269-274
- ISSN
- 2198-0810 (ISSN-L)
- 2288-6206
- OpenAlex
- W2242147101
- Cited by
- 13
- References
- 29
- Citations by year
- 2024: 1 · 2022: 1 · 2021: 1 · 2018: 1 · 2017: 6 · 2016: 3
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- International Journal of Precision Engineering and Manufacturing-Green Technology (publishedVersion)
- Funders
- National Research Foundation
- Ministry of Science, ICT and Future Planning (IITP-2015, IITP-2015-H8601-15-1001)
- National Research Foundation of Korea (NRF-2013R1A1A2010764)
- Ministry of Education, Science and Technology (NRF-2013R1A1A2010764)
- Iran Telecommunication Research Center
- Institute for Information and Communications Technology Promotion
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Control and Systems Engineering › Magnetic Bearings and Levitation Dynamics
- Physical Sciences › Engineering › Aerospace Engineering › Aeroelasticity and Vibration Control
- Keywords
- active vibration isolation, natural frequency tuning, PID control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.