The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimising ventilation to control odour in the ventilated improved pit latrine
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Use of insect screens in windows results in a 7% reduction in the ventilation rate through the vent pipe if all other factors are held constant.
“But their use may result in loss of air pressure across the screen [31] and found to result in 7 % reduction in the ventilation rate through the vent pipe if all other factors are held constant [32].”
From Compliance of private ventilated improved pit latrines to odour and fly control guidelines: A technical audit in selected regions of Ghana (2024) · cites this paper as [32]
Citations
Cites
Accelerating uptake of household latrines in rural communities in the Volta region of Ghana’
Keraita, B., Jensen, P. K. M., Konradsen, F., Akple, M., & Rheinländer, T. (2013) · Journal of Water, Sanitation and Hygiene for Development · doi:10.2166/washdev.2013.035 · Cited by 18
Self-citation
Flagged first, then by citations
Research works printed but not linked: 12
- Autodesk Sustainability Workshop (2011) Stack ventilation and Bernoulli’s principle. http://sustainabilityworkshop.autodesk.com/buildings/stack-ventilation-and-bernoullis-principle . Accessed 2 May 2015
- Awbi HB (1994) Design considerations for naturally ventilated buildings. Renew Energy 5(II):1081–1090 · DOI
- Darby R (2001) Chemical engineering fluid mechanics, 2nd edn. Marcel Dekker, Inc., New York
- Karnib A (2014) A methodological approach for quantitative assessment of the effective wastewater management: Lebanon as a case study. Environ Process 1(4):483–495. https://doi.org/10.1007/s40710-014-0032-8 · DOI
- Kvarnstrom E, McConville J, Bracken P, Johansson M, Fogde M (2011) The sanitation ladder—a need for a revamp? J Water Sanit Hyg Dev. https://doi.org/10.2166/washdev.2011.014 · DOI
- Ningo Prampram District Assembly (2012) Socio-Economic database. Ningo Prampram District Assembly, Prampram
- Obeng PA (2016) Usage barriers and improvement of the improved pit latrine for use in peri-urban settings of Ghana. Doctoral dissertation, Kwame Nkrumah University of Science and Technology
- Obeng PA, Keraita B, Oduro-Kwarteng S, Bregnhøj H, Abaidoo RC, Awuah E, Konradsen F (2015) Usage and barriers to use of latrines in a Ghanaian peri-urban community. Environ Process 2:261–274. https://doi.org/10.1007/s40710-015-0060-z · DOI · Paper page
- Obeng PA, Keraita B, Oduro-Kwarteng S, Bregnhoj H, Abaidoo RC, Awuah E, Konradsen F (2016) Measurement of odour in on-site sanitation systems in low-income settings. Environ Process 3:217–227. https://doi.org/10.1007/s40710-016-0124-8 · DOI
- Paterson C, Mara D, Curtis T (2007) Pro-poor sanitation technologies. Geoforum 38:901–907 · DOI
- Wong NH, Heryanto S (2004) The study of active stack effect to enhance natural ventilation using wind tunnel and computational fluid dynamics (CFD) simulations. Energy Build 36:668–678 · DOI
- World Health Organisation (2000) Air quality guidelines, 2nd edn. WHO Regional Office for Europe, Copenhagen
Cited by
Sorted by citations
Obeng, P. A., Donkor, E. A., Awere, E., Oduro-Kwarteng, S., Obeng, P. A., & Awuah, E. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e33980 · Cited by 6
“But their use may result in loss of air pressure across the screen [31] and found to result in 7 % reduction in the ventilation rate through the vent pipe if all other factors are held constant [32].”
BackgroundSelf-citation
Metadata
- Authors
- Obeng, P. A., Oduro-Kwarteng, S., Keraita, B., Bregnhøj, H., Abaidoo, R. C., Awuah, E., & Konradsen, F.
- Affiliations
- University of Cape Coast (GH)
- University of Copenhagen (DK)
- Kwame Nkrumah University of Science and Technology (GH)
- Corresponding author
- Obeng, Peter A.
- Venue
- Modeling Earth Systems and Environment
- Published
- 2018-10-11
- Volume
- 5
- Issue
- 1
- Pages
- 133-142
- ISSN
- 2363-6203 (ISSN-L)
- 2363-6211
- OpenAlex
- W2897066978
- Cited by
- 8
- References
- 1
- Citations by year
- 2025: 2 · 2024: 1 · 2023: 1 · 2022: 1 · 2020: 1 · 2019: 2
- FWCI
- 0.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Modeling Earth Systems and Environment (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- Funders
- Danida Fellowship Centre (FFU-10-050KU)
- Topics
- Physical Sciences › Chemical Engineering › Process Chemistry and Technology › Odor and Emission Control Technologies
- Physical Sciences › Environmental Science › Environmental Engineering › Wind and Air Flow Studies
- Physical Sciences › Environmental Science › Waste Management and Disposal › Landfill Environmental Impact Studies
- Keywords
- ventilated improved pit latrines, odor control, ventilation rate, wind speed, latrine design, regression models
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review