Self-Healing Liquid Metal Magnetic Hydrogels for Smart Feedback Sensors and High-Performance Electromagnetic Shielding
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Hydrogels exhibit potential applications in smart wearable devices because of their exceptional sensitivity to various external stimuli. However, their applications are limited by challenges in terms of issues in biocompatibility, custom shape, and self-healing. Herein, a conductive, stretchable, adaptable, self-healing, and biocompatible liquid metal GaInSn/Ni-based composite hydrogel is developed by incorporating a magnetic liquid metal into the hydrogel framework through crosslinking polyvinyl alcohol (PVA) with sodium tetraborate. The excellent stretchability and fast self-healing capability of the PVA/liquid metal hydrogel are derived from its abundant hydrogen binding sites and liquid metal fusion. Significantly, owing to the magnetic constituent, the PVA/liquid metal hydrogel can be guided remotely using an external magnetic field to a specific position to repair the broken wires with no need for manual operation. The composite hydrogel also exhibits sensitive deformation responses and can be used as a strain sensor to monitor various body motions. Additionally, the multifunctional hydrogel displays absorption-dominated electromagnetic interference (EMI) shielding properties. The total shielding performance of the composite hydrogel increases to ~ 62.5 dB from ~ 31.8 dB of the pure PVA hydrogel at the thickness of 3.0 mm. The proposed bioinspired multifunctional magnetic hydrogel demonstrates substantial application potential in the field of intelligent wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electromagnetic interference shielding with 2D transition metal carbides (MXenes)
Shahzad, F., Alhabeb, M., Hatter, C. B., Anasori, B., Man Hong, S., Koo, C. M., & Gogotsi, Y. (2016) · Science · doi:10.1126/science.aag2421 · Cited by 5,201
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908 · cited 1×
“In contrast to metal liquid-filled elastomers, hydrogels are a type of engineering material composed of a crosslinked network of hydrophilic blocks surrounded by water [35], demonstrating the potential for absorption-based EMI blocking [36].”
BackgroundChen, Z., Xu, C., Ma, C., Ren, W., & Cheng, H. (2013) · Advanced Materials · doi:10.1002/adma.201204196 · Cited by 1,986
Liu, J., Zhang, H., Sun, R., Liu, Y., Liu, Z., Zhou, A., & Yu, Z. (2017) · Advanced Materials · doi:10.1002/adma.201702367 · Cited by 1,819
Liquid metals: fundamentals and applications in chemistry
Daeneke, T., Khoshmanesh, K., Mahmood, N., de Castro, I. A., Esrafilzadeh, D., Barrow, S. J., Dickey, M. D., & Kalantar-zadeh, K. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00043j · Cited by 1,222
Markvicka, E. J., Bartlett, M. D., Huang, X., & Majidi, C. (2018) · Nature Materials · doi:10.1038/s41563-018-0084-7 · Cited by 1,067 · cited 1×
“…the fluidity and deformability of liquid metals in aqueous environments are promising for applications in various fields, such as flexible electronics [4–6], soft robotics [7, 8], energy harvesting/storage [9, 10], microfluidics [11], sensors [12], actuators [13, 14], and wearable sensing [15].”
BackgroundWu, Z., Pei, K., Xing, L., Yu, X., You, W., & Che, R. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201901448 · Cited by 817
Self-citationYu, Z.-Y., Lang, C.-C., Gao, M.-R., Chen, Y., Fu, Q.-Q., Duan, Y., & Yu, S.-H. (2018) · Energy & Environmental Science · doi:10.1039/c8ee00521d · Cited by 803
Ricciardi, R., Auriemma, F., De Rosa, C., & Lauprêtre, F. (2004) · Macromolecules · doi:10.1021/ma035663q · Cited by 784
Recent advances in carbon-based polymer nanocomposites for electromagnetic interference shielding
Abbasi, H., Antunes, M., & Velasco, J. I. (2019) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.02.003 · Cited by 744
Cited by
Gai, L., Wang, Y., Wan, P., Yu, S., Chen, Y., Han, X., Xu, P., & Du, Y. (2024) · Nano-Micro Letters · doi:10.1007/s40820-024-01369-6 · Cited by 191
“However, we also face the challenge of spatial electromagnetic (EM) contamination caused by the widespread use of communication equipment, which has become a Gordian knot in both civil and military fields [4, 5].”
Self-citationZhang, W., Wang, P.-L., Huang, L.-Z., Guo, W.-Y., Zhao, J., & Ma, M.-G. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108875 · Cited by 176
Metadata
- Authors
- Zhao, B., Bai, Z., Lv, H., Yan, Z., Du, Y., Guo, X., Zhang, J., Wu, L., Deng, J., Zhang, D. W., & Che, R.
- Venue
- Nano-Micro Letters
- Published
- 2023-03-31
- Volume
- 15
- Issue
- 1
- Pages
- 79-79
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W4362466068
- Cited by
- 290
- References
- 58
- FWCI
- 21.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.