Flexible Nanocomposite Conductors for Electromagnetic Interference Shielding
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Highlights: Convincing candidates of flexible (stretchable/compressible) electromagnetic interference shielding nanocomposites are discussed in detail from the views of fabrication, mechanical elasticity and shielding performance. Detailed summary of the relationship between deformation of materials and electromagnetic shielding performance. The future directions and challenges in developing flexible (particularly elastic) shielding nanocomposites are highlighted. With the extensive use of electronic communication technology in integrated circuit systems and wearable devices, electromagnetic interference (EMI) has increased dramatically. The shortcomings of conventional rigid EMI shielding materials include high brittleness, poor comfort, and unsuitability for conforming and deformable applications. Hitherto, flexible (particularly elastic) nanocomposites have attracted enormous interest due to their excellent deformability. However, the current flexible shielding nanocomposites present low mechanical stability and resilience, relatively poor EMI shielding performance, and limited multifunctionality. Herein, the advances in low-dimensional EMI shielding nanomaterials-based elastomers are outlined and a selection of the most remarkable examples is discussed. And the corresponding modification strategies and deformability performance are summarized. Finally, expectations for this quickly increasing sector are discussed, as well as future challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644 · cited 1×
“For elastic EMI shielding materials, traditional metal plates, metal nets (etched from metal plates), and other traditional rigid [280].”
BackgroundHighly conductive and elastic nanomembrane for skin electronics
Jung, D., Lim, C., Shim, H. J., Kim, Y., Park, C., Jung, J., Han, S. I., Sunwoo, S.-H., Cho, K. W., Cha, G. D., et al. (2021) · Science · doi:10.1126/science.abh4357 · Cited by 403 · cited 1×
“Particularly, illustrative metal nanowires including gold nanowires (AuNWs) [131–135], AgNWs [136–140], copper nanowires (CuNWs) [141] are utilized in a range of stretchy conductive materials due to their ultrahigh anisotropy ratio, which facilitates the formation of a more stable conductive…”
BackgroundUltralight Conductive Silver Nanowire Aerogels
Qian, F., Lan, P. C., Freyman, M. C., Chen, W., Kou, T., Olson, T. Y., Zhu, C., Worsley, M. A., Duoss, E. B., Spadaccini, C. M., et al. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02790 · Cited by 207
Metadata
- Authors
- Nan, Z., Wei, W., Lin, Z., Chang, J., & Hao, Y.
- Venue
- Nano-Micro Letters
- Published
- 2023-07-07
- Volume
- 15
- Issue
- 1
- Pages
- 172-172
- ISSN
- 2150-5551 (ISSN-L)
- 2311-6706
- OpenAlex
- W4383499600
- Cited by
- 212
- References
- 3
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Nanocomposite Conductors for Electromagnetic Interference Shielding. https://app.cochat.ai/papers/10.1007/s40820-023-01122-5
- The paper
- Nan, Z., Wei, W., Lin, Z., Chang, J., & Hao, Y. (2023). Flexible Nanocomposite Conductors for Electromagnetic Interference Shielding. Nano-Micro Letters. https://doi.org/10.1007/s40820-023-01122-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.