Opinion: hazards faced by macromolecules when confined to thin aqueous films
Open accessThe DOI matches its Crossref record.
Abstract
Samples prepared for single-particle electron cryo-microscopy (cryo-EM) necessarily have a very high surface-to-volume ratio during the short period of time between thinning and vitrification. During this time, there is an obvious risk that macromolecules of interest may adsorb to the air-water interface with a preferred orientation, or that they may even become partially or fully unfolded at the interface. In addition, adsorption of macromolecules to an air-water interface may occur even before thinning. This paper addresses the question whether currently used methods of sample preparation might be improved if one could avoid such interfacial interactions. One possible way to do so might be to preemptively form a surfactant monolayer over the air-water interfaces, to serve as a structure-friendly slide and coverslip. An alternative is to immobilize particles of interest by binding them to some type of support film, which-to continue using the analogy-thus serves as a slide. In this case, the goal is not only to prevent the particles of interest from diffusing into contact with the air-water interface but also to increase the number of particles seen in each image. In this direction, it is natural to think of developing various types of affinity grids as structure-friendly alternatives to thin carbon films. Perhaps ironically, if precautions are not taken against adsorption of particles to air-water interfaces, sacrificial monolayers of denatured protein may take the roles of slide, coverslip, or even both.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Addressing preferred specimen orientation in single-particle cryo-EM through tilting
Tan, Y. Z., Baldwin, P. R., Davis, J. H., Williamson, J. R., Potter, C. S., Carragher, B., & Lyumkis, D. (2017) · Nature Methods · doi:10.1038/nmeth.4347 · Cited by 903
Cryo-EM in drug discovery: achievements, limitations and prospects
Renaud, J.-P., Chari, A., Ciferri, C., Liu, W.-T., Rémigy, H.-W., Stark, H., & Wiesmann, C. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.77 · Cited by 461
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
Protein denaturation at the air-water interface and how to prevent it
D'Imprima, E., Floris, D., Joppe, M., Sánchez, R., Grininger, M., & Kühlbrandt, W. (2019) · eLife · doi:10.7554/elife.42747 · Cited by 297
Routine single particle CryoEM sample and grid characterization by tomography
Noble, A. J., Dandey, V. P., Wei, H., Brasch, J., Chase, J., Acharya, P., Tan, Y. Z., Zhang, Z., Kim, L. Y., Scapin, G., et al. (2018) · eLife · doi:10.7554/elife.34257 · Cited by 296
Metadata
- Authors
- Glaeser, R. M., & Han, B.-G.
- Venue
- Biophysics Reports
- Published
- 2016-07-22
- Volume
- 3
- Issue
- 1-3
- Pages
- 1-7
- ISSN
- 2364-3439 (ISSN-L)
- 2364-3420
- OpenAlex
- W2492347222
- Cited by
- 149
- References
- 0
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Opinion: hazards faced by macromolecules when confined to thin aqueous films. https://app.cochat.ai/papers/10.1007/s41048-016-0026-3
- The paper
- Glaeser, R. M., & Han, B.-G. (2017). Opinion: hazards faced by macromolecules when confined to thin aqueous films. Biophysics Reports. https://doi.org/10.1007/s41048-016-0026-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.