The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Electrophysiologic testing in bundle branch block and unexplained syncope
Abstract
Thirty-two patients with bundle branch block and unexplained syncope underwent electrophysiologic testing, including programmed ventricular stimulation with up to triple extrastimuli. The infranodal conduction time (HV) was 70 ms or greater in 12 patients. Pathologic infranodal block during atrial pacing occurred in 2 patients. Unimorphic ventricular tachycardia (VT) was induced in 9 patients (28%) and polymorphic VT in 5 (16%). A permanent pacemaker was implanted in patients with infranodal block during atrial pacing and, generally, in patients with an HV of 70 ms or more. Patients with inducible unimorphic or sustained polymorphic VT were treated with an antiarrhythmic drug. The mean follow-up period was 19 +/- 14 months (+/- standard deviation). Three patients died suddenly: a noncompliant patient with inducible sustained VT; a patient with a normal electrophysiologic study treated empirically with quinidine for premature ventricular complexes; and a patient with an HV of 70 ms and no inducible VT treated with a permanent pacemaker. The actuarial incidence of sudden death was 10% at 45 months of follow-up. Only 2 patients had recurrent syncope; both had a normal electrophysiologic study. Approximately 50% of patients with bundle branch block and unexplained syncope who undergo electrophysiologic testing are found to have a clinically significant abnormality (HV of 70 ms or more, infranodal block during atrial pacing and inducible unimorphic VT), and some patients have more than 1 abnormality. Long-term management guided by the results of electrophysiologic testing generally is successful in preventing recurrent syncope.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a high incidence of total deaths (about one-third sudden) was observed in patients with BBB and heart failure, previous myocardial infarction, or low ejection fraction. 345-347”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [346]
In the citing paper
“Although syncope is not associated with an increased incidence of sudden death in patients with preserved cardiac function”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [346]
In the citing paper
“Unfortunately, ventricular programmed stimulation does not seem to identify these patients correctly”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [346]
Citations
Cites
Natural History of High-Risk Bundle-Branch Block: Final Report of a Prospective Study
McAnulty, J. H., Rahimtoola, S. H., Murphy, E., DeMots, H., Ritzmann, L., Kanarek, P. E., & Kauffman, S. (1982) · New England Journal of Medicine · doi:10.1056/nejm198207153070301 · Cited by 319
Brugada, P., Green, M. S., Abdollah, H., & Wellens, H. J. J. (1984) · Circulation · doi:10.1161/01.cir.69.1.87 · Cited by 308
Buxton, A. E., Waxman, H. L., Marchlinski, F. E., Untereker, W. J., Waspe, L. E., & Josephson, M. E. (1984) · Circulation · doi:10.1161/01.cir.69.3.532 · Cited by 256
Scheinman, M. M., Peters, R. W., Sauvé, M. J., Desai, J., Abbott, J. A., Cogan, J., Wohl, B., & Williams, K. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90469-6 · Cited by 249
Self-citationIntracardiac Electrophysiologic Techniques in Recurrent Syncope of Unknown Cause
Dimarco, J., Garan, H., HARTHORNE, J. W., & Ruskin, J. N. (1981) · Annals of Internal Medicine · doi:10.7326/0003-4819-95-5-542 · Cited by 216
Clinical pharmacology and therapeutic applications of the antiarrhythmic agent, amiodarone
Marcus, G. M., Fontaine, G. H., Frank, R., & Grosgogeat, Y. (1981) · American Heart Journal · doi:10.1016/0002-8703(81)90140-x · Cited by 209
Dhingra, R. C., Wyndham, C. R. C., Bauernfeind, R. A., Swiryn, S., DEEDWANIA, P. C., Smith, T., DENES, P., & Rosen, K. M. (1979) · Circulation · doi:10.1161/01.cir.60.7.1455 · Cited by 160
PBrugada, MGreen, HAbdollah, et al. (1984) · Circulation · Cited by 156
Brugada, P., Abdollah, H., Heddle, B., & Wellens, H. J. J. (1983) · The American Journal of Cardiology · doi:10.1016/0002-9149(83)90576-3 · Cited by 155
Electrophysiologic testing in the evaluation of patients with syncope of undetermined origin
Hess, D., Morady, F., & Scheinman, M. M. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90468-4 · Cited by 154
Self-citation
Cited by
Sorted by citations
Items 101–137 of 137
Indications for Pacing in Patients With Unexplained Syncope and Bifascicular Block
Oseroff, O., & Galizio, N. O. (2020) · Springer eBooks · doi:10.1007/978-3-030-44507-2_21 · Cited by 3
Syncope and Arrhythmias: Role of the Electrophysiological Study
Stouffer, G. A., Sheahan, R. G., Lenihan, D. J., & Sheahan, R. G. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200107000-00007 · Cited by 3
Syncope: A Practical Diagnostic Approach
ABI‐SAMRA, F. M., Fouad, F. M., Sweeney, P., & Maloney, J. D. (1987) · Clinical medicine and the nervous system · doi:10.1007/978-1-4471-3129-8_14 · Cited by 3
Investigation and Clinical Significance of Arrhythmias in Patients with Hypertrophic Cardiomyopathy
Fananapazir, L., Epstein, S. E., & Epstein, N. D. (1991) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1991.tb01355.x · Cited by 3
Bradycardia and Cardiac Conduction Delay Guideline Update
Marzlin, K. M. (2020) · AACN Advanced Critical Care · doi:10.4037/aacnacc2020703 · Cited by 2
Táborský, M., Kautzner, J., Fedorco, M., Čurila, K., Wünschová, H., Pyszko, J., Novák, M., Kozák, M., Válek, M., Polášek, R., et al. (2022) · Cor et Vasa · doi:10.33678/cor.2022.024 · Cited by 4
Schoenfeld, M. H., Silka, M. J., Stevenson, L. W., Hammill, C. W., Hayes, D. L., Hlatky, M. A., Newby, L. K., Richard, L., Freedman, R. A., Gettes, L. S., et al. (2008) · Cited by 2
Pacing for Atrioventricular Conduction System Disease
Stambler, B. S., Rahimtoola, S. H., & Ellenbogen, K. A. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.50019-4 · Cited by 2
Use of Electrophysiology Studies in Syncope: Practical Aspects for Diagnosis and Treatment
TELFER, E. A., & Olshansky, B. (2005) · Wiley eBooks · doi:10.1002/9780470994801.ch6 · Cited by 2
Analytic Reviews: Electrophysiologic Testing in the Intensive Care Unit
Nalos, P. C., Myers, M. R., Gang, E. S., Peter, T. C., & Mandel, W. J. (1987) · Journal of Intensive Care Medicine · doi:10.1177/088506668700200503 · Cited by 2
Evaluation of the Patient with Syncope
DiCarlo, L. A., & Morady, F. (1985) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30648-9 · Cited by 2
Self-citationSeidl, K., Drögemüller, A., Rameken, M., Schneider, S., Zahn, R., & Senges, J. (2003) · Zeitschrift für Kardiologie · doi:10.1007/s00392-003-0969-5 · Cited by 2
Zhelyakov, E. G., & Av, A. (2022) · Cardiac Arrhythmias · doi:10.17816/cardar108972 · Cited by 1
Good, E. D., & Jongnarangsin, K. (2020) · Springer eBooks · doi:10.1007/978-3-030-28328-5_17 · Cited by 1
2018 KHRS guideline for the evaluation and management of syncope-Part 1
Park, J., Cha, M.-J., Kim, D. H., Kim, Y. R., Mun, H. S., Bae, E. J., Seo, D. W., Song, M. K., Ahn, J., Yoon, H. D., et al. (2018) · International Journal of Arrhythmia · doi:10.18501/arrhythmia.2018.009 · Cited by 1
Chapelon-Abric, C. (2005) · EMC - Cardiologie · doi:10.1016/s1166-4568(05)37881-8 · Cited by 1
Evaluation and Management of Syncope
Bindra, P. S., Marchlinski, F. E., & Lin, D. (2008) · Clinical Medicine Insights Circulatory Respiratory and Pulmonary Medicine · doi:10.4137/ccrpm.s490
Bradyarrhythmias and Indications for Pacing
Peters, R. W., & Gold, M. R. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_11
Self-citationIntroduction to Clinical Electrophysiology
Rubenstein, D. G., & Zaher, C. (1989) · Springer eBooks · doi:10.1007/978-1-4612-3534-7_10
Rezidivierende Synkopen bei Linksschenkelblock mit normaler PQ-Zeit
Alter, P. J., & Grimm, W. (2002) · Der Internist · doi:10.1007/s00108-002-0555-3
Zipes, D. P., Buxton, A. E., Gregoratos, G., Moss, A. J., Myerburg, R. J., Priori, S. G., Quiñones, M. A., von Roden, M., & Silka, M. J. (2006)
Clinical Aspects of Cardiac Pacing for Bradyarrhythmias
Ruiter, J. H. (1992) · RePub (Erasmus University Rotterdam) · doi:10.13140/rg.2.2.17317.29925
Raviele, A. (2002) · Springer eBooks · doi:10.1007/978-88-470-2103-7_10
Exploration électrophysiologique endocavitaire
LASCAULT, G. (2004) · EMC - Cardiologie-Angéiologie · doi:10.1016/j.emcaa.2004.02.003
Trends in Cardiovascular Devices
Semples, S. (2008) · Journal of Clinical Engineering · doi:10.1097/01.jce.0000337791.71923.e8
Sweeney, M. O., Schoenfeld, M. H., Silka, M. J., Stevenson, L. W., Hammill, S. C., Hayes, D. L., Hlatky, M. A., Newby, L. K., Freedman, A. L., Gettes, L. S., et al. (2010)
Benditt, D. G., Blanc, F. J.-J., Brignole, F. M., & DScMed, F. R. S. (2006) · Wiley eBooks · doi:10.1002/9781444312812.refs
Electrophysiology Testing: Appropriate Indications in TLOC/Collapse
Sorajja, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-44507-2_16
Andries, E., Willems, H., Gürsoy, S., Nellens, P., Goethals, M. A., & Brugada, P. (1992) · Developments in cardiovascular medicine · doi:10.1007/978-94-011-2582-6_1
Therapeutic options in the management of life-threatening arrhythmias.
Herre, J. M., & Griffin, J. C. (1989) · PubMed Central
Hanna, E. B. (2022) · Wiley eBooks · doi:10.1002/9781119832737.ch13
(2017) · Wiley eBooks · doi:10.1002/9781119233503.ch13
Fowler, N. O. (1991) · Springer eBooks · doi:10.1007/978-1-4612-3068-7_29
Can, I., & Benditt, D. G. (2010) · Humana Press eBooks · doi:10.1007/978-1-60761-161-5_18
Chapelon-Abric, C. (2005) · EMC - Cardiologie-Angéiologie · doi:10.1016/j.emcaa.2005.07.006
Exploration électrophysiologique
Gal, B., Lacroix, D., & Brigadeau, F. (2009) · EMC - Cardiologie · doi:10.1016/s1166-4568(09)48254-8
Changing Concepts of Electrophysiology Testing for Ventricular Arrhythmias
Akhtar, M. (2000) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1009801809035
Metadata
- Authors
- Morady, F., Higgins, J., Peters, R. W., Schwartz, A. B., Shen, E. N., Bhandari, A., Scheinman, M. M., & Sauvé, M. J.
- Affiliations
- University of California, San Francisco (US)
- Corresponding author
- Morady, Fred
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1984-09
- Volume
- 54
- Issue
- 6
- Pages
- 587-591
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2059208803
- Cited by
- 138
- References
- 21
- Citations by year
- 2026: 1 · 2023: 1 · 2022: 5 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 9 · 2017: 7 · 2016: 3 · 2012: 2
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- bundle branch block, unexplained syncope, electrophysiologic testing, programmed ventricular stimulation, polymorphic ventricular tachycardia, permanent pacemaker, antiarrhythmic drugs, sudden death, recurrent syncope, quinidine
- MeSH terms
- Adolescent, Adult, Aged, Bundle-Branch Block, Cardiac Pacing, Artificial, Child, Death, Sudden, Electrocardiography, Female, Humans, Male, Middle Aged, Pacemaker, Artificial, Syncope, Tachycardia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review