CoChat

Predictors of rhythm disturbances and subsequent morbidity after the Fontan operation

Open access
Weber, Howard S., Hellenbrand, William E., Kleinman, Charles S., Perlmutter, Robin A., Rosenfeld, Lynda E. · 1989 · The American Journal of Cardiology
Cited by 72

The DOI matches its Crossref record.

Abstract

The electrocardiographic, hemodynamic and surgical data of 30 patients who underwent a Fontan operation between 1977 and 1986 were retrospectively reviewed to identify the incidence and predictors of immediate and late postoperative arrhythmias and associated morbidity in long-term survivors. Of 4 patients who died <1 year after operation (mortality 13%), 1 death was related to an arrhythmia. Three patients were not in sinus rhythm before operation and were excluded from the statistical analysis that examined predictors of arrhythmias. The remaining 23 long-term survivors have been followed 6.3 ± 2.6 years (mean ± standard deviation) since surgery and all remain in New York Heart Association functional class I or II. Ten patients (43%) developed immediate postoperative arrhythmias (≤ 30 days) whereas 11 (48%) had late arrhythmias. With up to 10.7 years of followup, the proportion of patients free from late arrhythmias continues to decline. Arrhythmias included bradyarrhythmias, atrial tachyarrhythmias, the tachy-brady syndrome and supraventricular ectopic activity. Immediate postoperative arrhythmias predicted late arrhythmias (p = 0.022). The preoperative electrocardiogram was the only variable useful in predicting both immediate and late postoperative arrhythmias. A more negative P-wave deflection in lead V 1 (-2.4 ± 0.7 vs -1.4 ± 1.2 mV, p=0.02) predicted patients with immediate postoperative arrhythmias, whereas both greater P-wave duration and a more negative deflection in this lead predicted late arrhythmias (103 ± 14 vs 83 ± 20 ms, p=0.01, and -2.5 ± 0.8 vs −1.3 ±1.0 mV, p=0.005, respectively). Of the 26 surviving patients, 10 (38%) have required ≥1 hospitalizations for control of late arrhythmias. Eight patients are receiving maintenance therapy with multiple antiarrhythmic drugs including amiodarone (1 patient) and 5 have received permanent epicardial pacemakers. Thus, despite excellent functional results after the Fontan operation, postoperative arrhythmias are frequent and cause significant morbidity that will continue to increase with time. Atrial abnormalities on the preoperative electrocardiogram predict those patients who will develop arrhythmias both in the immediate and late postoperative periods. The appearance of an immediate postoperative arrhythmia also predicts the subsequent development of late arrhythmias. Recognition of these predictors may facilitate monitoring and therapy of such patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0002-9149(89)90761-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Weber, H. S., Hellenbrand, W. E., Kleinman, C. S., Perlmutter, R. A., & Rosenfeld, L. E.
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
1989-10
Volume
64
Issue
12
Pages
762-767
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2045543953
Cited by
72
References
0
FWCI
3.78
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.