The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Reliability of blood glucose monitoring by patients with diabetes mellitus
Abstract
Nineteen patients with insulin-dependent diabetes mellitus were evaluated for overall reliability of self-generated data from capillary blood glucose monitoring. For a period of 12 to 14 days, standard reflectance meters used by these subjects were replaced by meters internally modified with memory chips capable of storing all glucose readings by date and time. The subjects were not aware of this modification and were instructed to continue to test capillary blood glucose as they had been and to continue their practice of recording the meter readings in a logbook. To assess reliability of patient-generated data as recorded in the logbook, the addition, deletion, and alteration of test results were determined. A significantly lower (p less than 0.0001) mean blood glucose level was reported in the logbooks than recorded in the memory reflectance meters. Differences in logbooks and memory reflectance meters ranged from 0 to 109 mg/dl. Three fourths of the subjects had reported lower than actual mean blood glucose values. Under-reporting, or omission of memory reflectance meter readings, averaged 10 percent, whereas over-reporting or addition of phantom values averaged 40 percent. An average of 26 percent of the logbook entries were not identical to memory reflectance meter values determined at the corresponding time. Two thirds of the subjects had reported values in such a manner as to obscure hyper- and hypoglycemia, leading to misleading clinical impressions about the fluctuat…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Today, the development of devices for glucose monitoring with high reliability need new technologies and strategies to make those sensors more affordable, non-invasive, and suitable for continuous monitoring of glycemic status 40-42.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [40]
Citations
Cites
Correlation of Glucose Regulation and Hemoglobin A Ic in Diabetes Mellitus
Koenig, R. J., Peterson, C. M., Jones, R. L., Saudek, C. D., Lehrman, M. A., & Cerami, A. (1976) · New England Journal of Medicine · doi:10.1056/nejm197608192950804 · Cited by 1,173
Hemoglobin Components in Patients with Diabetes Mellitus
Trivelli, L., Ranney, H. M., & Lai, H.-T. (1971) · New England Journal of Medicine · doi:10.1056/nejm197102182840703 · Cited by 841
Glycosylated Hemoglobins and Long-Term Blood Glucose Control in Diabetes Mellitus
Gabbay, K. H., Hasty, K. A., Breslow, J. L., Ellison, R. C., Bunn, H. F., & Gallop, P. M. (1977) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-44-5-859 · Cited by 520
Relation of diabetic control to development of microvascular complications
Tchobroutsky, G. (1978) · Diabetologia · doi:10.1007/bf00421230 · Cited by 425
HOME MONITORING OF BLOOD-GLUCOSE
Sönksen, P. H., Judd, S. L., & Lowy, C. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90854-1 · Cited by 342
SELF-MONITORING OF BLOOD-GLUCOSE
Walford, S., Gale, E. A. M., Allison, S. P., & Tattersall, R. B. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90855-3 · Cited by 269
Jovanovič, L., Druzin, M. L., & Peterson, C. M. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90301-6 · Cited by 268
Schiffrin, A., & Belmonte, M. M. (1982) · Diabetes Care · doi:10.2337/diacare.5.5.479 · Cited by 194
Special Comment: Meticulous Control of Diabetes: Benefits, Risks, and Precautions
Unger, R. H. (1982) · Diabetes · doi:10.2337/diab.31.6.479 · Cited by 134
complications of Diabetes Mellitus: Relationship to Metabolic Dysfunction
Skyler, J. S. (1979) · Diabetes Care · doi:10.2337/diacare.2.6.499 · Cited by 102
Cited by
Sorted by citations
Items 101–200 of 261
Consistency between Self-Reported and Recorded Values for Clinical Measures
Thomas, J., Paulet, M., & Rajpura, J. R. (2016) · Cardiology Research and Practice · doi:10.1155/2016/4364761 · Cited by 18
Zeng, Y., Wu, J., Han, Y., Chen, F., Chen, L., Yang, S., & Fang, Y. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12651 · Cited by 18
A prospective evaluation of glucose reagent teststrips in the prehospital setting
Lavery, R., Allegra, J. R., Rp, C., Zacharias, D., & Schreck, D. (1991) · The American Journal of Emergency Medicine · doi:10.1016/0735-6757(91)90046-m · Cited by 18
Self-monitoring of blood glucose and insulin dose alteration in type 1 diabetes mellitus
Ziegler, O., Kolopp, M., Louis, J., Musse, J. P., Patris, A., Debry, G., & Drouin, P. (1993) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(93)90097-o · Cited by 18
Psychological Factors and Metabolic Control: Time for Reappraisal?
Williams, G., Pickup, J. C., & Keen, H. (1988) · Diabetic Medicine · doi:10.1111/j.1464-5491.1988.tb00972.x · Cited by 18
Langer, O., & Mazze, R. S. (1987) · Practical Diabetes · doi:10.1002/pdi.1960040110 · Cited by 18
Self-citationDiabetology 4.0: Scoping Review of Novel Insights and Possibilities Offered by Digitalization
Eberle, C., Stichling, S., & Löhnert, M. (2021) · Journal of Medical Internet Research · doi:10.2196/23475 · Cited by 18
Is home blood pressure reporting in patients with type 2 diabetes reliable?
Matsumoto, S., Fukui, M., Hamaguchi, M., Ushigome, E., Matsushita, K., Fukuda, T., Mitsuhashi, K., Majima, S., Hasegawa, G., & Nakamura, N. (2014) · Hypertension Research · doi:10.1038/hr.2014.66 · Cited by 17
Self-Monitoring of Blood Pressure
Pickering, T. G. (2001) · Humana Press eBooks · doi:10.1007/978-1-59259-004-9_1 · Cited by 17
Delamater, A. M., Kurtz, S. M., White, N. H., & Santiago, J. V. (1988) · Journal of Applied Social Psychology · doi:10.1111/j.1559-1816.1988.tb00031.x · Cited by 17
To What Extent Can We Trust Home Blood Pressure Measurement? A Randomized, Controlled Trial
Bachmann, L. M., Steurer, J., Holm, D., & Vetter, W. (2002) · Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2002.00953.x · Cited by 16
Blood Glucose Monitoring: Does Technology Help?
Page, S. R., & Peacock, I. (1993) · Diabetic Medicine · doi:10.1111/j.1464-5491.1993.tb00168.x · Cited by 16
Pre-existing diabetics: Relationship between glycemic control and emotional status in pregnancy
Langer, N., & Langer, O. (1998) · The Journal of Maternal-Fetal Medicine · doi:10.1002/(sici)1520-6661(199811/12)7:6 · Cited by 15
Ładyżyński, P., Wojcicki, J. M., Krzymień, J., Foltyński, P., Migalska‐Musial, K., Tracz, M., & Karnafel, W. (2006) · The International Journal of Artificial Organs · doi:10.1177/039139880602901108 · Cited by 15
Mazze, R., Simonson, G. D., Robinson, R. L., Kendall, D. M., Idrogo, M., Adlis, S. A., Boyce, K. S., Dunne, C. J., Anderson, R. L., & Bergenstal, R. M. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01027.x-i1 · Cited by 15
Self-citationIntensive insulin therapy in clinical practice
Home, P. (1997) · Diabetologia · doi:10.1007/s001250051412 · Cited by 15
Warnick, J. L., WESTEN, S. C., Albanese-O’Neill, A., Filipp, S. L., Schatz, D., Haller, M. J., & Janicke, D. M. (2020) · Diabetes Spectrum · doi:10.2337/ds19-0041 · Cited by 15
Biofeedback-assisted relaxation in insulin-dependent diabetes: A replication and extension study
McGrady, A. V., Graham, G., & Bailey, B. K. (1996) · Annals of Behavioral Medicine · doi:10.1007/bf02883396 · Cited by 14
Chae, M., Reith, D. M., Tomlinson, P. A., Rayns, J. A., & Wheeler, B. J. (2014) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/2251-6581-13-14 · Cited by 14
Ahn, D. T., & Salzman, R. S. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0101 · Cited by 14
Morrish, N. J., Cohen, D., Hicks, B. H., & KEEN, H. (1989) · Diabetic Medicine · doi:10.1111/j.1464-5491.1989.tb01234.x · Cited by 14
Burritt, M. F., Hanson, E., Munene, N. E., & Zimmennan, B. R. (1991) · Postgraduate Medicine · doi:10.1080/00325481.1991.11700859 · Cited by 14
Psychosocial Aspects of Diabetes in Childhood and Adolescence
Tattersall, R. B. (1987) · Pediatric Annals · doi:10.3928/0090-4481-19870901-09 · Cited by 14
Steward, D. A., Hofler, R. A., Thaldorf, C., & Milov, D. E. (2010) · Medical Decision Making · doi:10.1177/0272989x10371829 · Cited by 13
Home Blood Glucose Monitoring: Keystone for Modern Diabetes Care
McCall, A. L., & Mullin, C. J. (1987) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30841-0 · Cited by 13
Misdiagnosis of systemic hypertension and recommendations for improvement
Kaplan, N. M. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90624-2 · Cited by 13
Shamoon, H., Mazze, R. S., Pasmantier, R., Lucido, D., & Murphy, J. A. (1986) · The American Journal of Medicine · doi:10.1016/0002-9343(86)90669-8 · Cited by 13
Self-citationA Comparison of Automated Fructosamine and HbA 1c Methods for Monitoring Diabetes in Pregnancy
Kennedy, D. M., Johnson, A. B., & Hill, P. G. (1998) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329803500214 · Cited by 13
Yu, T. S., Song, S., Yea, J., & Jang, K. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400048 · Cited by 14
Advances in glucose monitoring: Improving diabetes management through evidence-based medicine
Mazze, R. S. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.03.001 · Cited by 12
Self-citationHome Monitoring of Diabetes Mellitus—A Quiet Revolution
McCall, A. L., & Mullin, C. J. (1986) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30808-4 · Cited by 12
Gebhart, S. S. P., Wheaton, R., Mullins, R. E., & Austin, G. E. (1991) · PubMed · Cited by 12
Diagnosing diabetes: blood glucose and the role of the laboratory
Higgins, C. (2001) · British Journal of Nursing · doi:10.12968/bjon.2001.10.4.5372 · Cited by 11
Making Sense of Glucose Monitoring Technologies: From SMBG to CGM
Mazze, R. S. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.784 · Cited by 11
Self-citationAccuracy of blood glucose estimates in adolescents with diabetes mellitus
Ruggiero, L., Kairys, S. W., Fritz, G. K., & WOOD, M. E. (1991) · Journal of Adolescent Health · doi:10.1016/0197-0070(91)90451-q · Cited by 11
(2011) · Wiley eBooks · doi:10.1002/9781119950424.ch5 · Cited by 12
Monitoring and controlling the patient with non-insulin-dependent diabetes mellitus
Jaspan, J. B. (1987) · Metabolism · doi:10.1016/0026-0495(87)90197-1 · Cited by 11
Assessment of glycaemic control in the diabetic clinic
Gill, G. V., & Huddle, K. (1989) · Practical Diabetes · doi:10.1002/pdi.1960060209 · Cited by 11
Baranyi, R., Willinger, R., Lederer, N., Walcher, F., & Grechenig, T. (2018) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah.2018.8401352 · Cited by 13
Comparing patient generated blood glucose diary records with meter memory in type 2 diabetes
Given, J. E., O'Kane, M., COATES, V. E., Moore, A., & Bunting, B. P. (2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2014.03.003 · Cited by 10
Blackwell, M., Tomlinson, P. A., Rayns, J. A., Hunter, J., Sjoeholm, A., & Wheeler, B. J. (2015) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/s40200-016-0238-6 · Cited by 10
Comparing Real-Time Self-Tracking and Device-Recorded Exercise Data in Subjects with Type 1 Diabetes
Groat, D., Kwon, H.-R., Grando, M., Cook, C., & Thompson, B. M. (2018) · Applied Clinical Informatics · doi:10.1055/s-0038-1676458 · Cited by 10
Diabetes Mellitus in Children and Adolescents
Sikes, K. A., & Tamborlane, W. V. (2013) · Humana Press eBooks · doi:10.1007/978-1-60761-395-4_28 · Cited by 10
Tzamaloukas, A. H., Hsi, K. C., Quintana, B. J., Merlin, T. L., & Avasthi, P. (1989) · PubMed Central · Cited by 10
Undetected, uncontrolled blood pressure in type 2 diabetes: self‐monitored blood pressure profiles
Mazze, R. S., Robinson, R., Simonson, G. D., Idrogo, M., Simpson, B. H., Kendall, D. M., & Bergenstal, R. M. (2004) · Blood Pressure · doi:10.1080/08037050410004774 · Cited by 10
Self-citationDunn, S. M. (1988) · Baillière s Clinical Endocrinology and Metabolism · doi:10.1016/s0950-351x(88)80045-4 · Cited by 10
Collecting Reliable and Valid Real-Time Patient Experience Data
Hufford, M. R., Stokes, T., & Paty, J. A. (2001) · Drug Information Journal · doi:10.1177/009286150103500314 · Cited by 10
Data Source Automation: New Technology for the Management of Patient‐generated Test Results
Saudek, C. D. (1989) · Diabetic Medicine · doi:10.1111/j.1464-5491.1989.tb01192.x · Cited by 10
Hufford, M. R., Stone, A. A., Shiffman, S. M., Schwartz, J. E., & Broderick, J. E. (2002) · Cited by 9
Improved diabetic prognosis following telecommunication and graphical processing of diabetic data.
Shultz, E. K., Bauman, A. J., Hayward, M. A., Rodbard, D., & Holzman, R. S. (1991) · PubMed Central · Cited by 9
Diabetes Patient Education: A Health Care Provider Perspective
Mazze, R. S. (1986) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572178601200208 · Cited by 9
Self-citationFaut-il faire peur aux patients ?
Reach, G. (2009) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(09)74751-0 · Cited by 8
Bernocchi, P., Baratti, D., Zanelli, E., Rocchi, S., Salvetti, M., Paini, A., & Scalvini, S. (2011) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/1741826710389364 · Cited by 8
Santamore, W. P., Homko, C. J., Kashem, A. M., McConnell, T. R., & Bové, A. A. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353135 · Cited by 8
McCance, D. R., Clarke, K. C., & Kennedy, L. (1989) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328902600109 · Cited by 8
Hahn, S. R. (2009) · CNS Spectrums · doi:10.1017/s1092852900024640 · Cited by 8
How Good Is Your Glucose Control?
Albisser, A. M., Alejandro, R., Meneghini, L., & Ricordi, C. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.863 · Cited by 8
Evaluation of Four Modern Home Blood Glucose Meters Including Two Memory Meters
Petranyi, G., Kyne, D. A., & Alberti, K. G. M. M. (1986) · Diabetic Medicine · doi:10.1111/j.1464-5491.1986.tb00741.x · Cited by 8
Baynes, K., Mcintosh, C., & Feher, M. D. (2001) · Practical Diabetes · doi:10.1002/pdi.165 · Cited by 8
Begley, J., & Forrest, A. R. W. (1988) · Journal of Clinical Pathology · doi:10.1136/jcp.41.4.397 · Cited by 8
Clark, C., Chin, M. H., Davis, S. N., Fisher, E. B., Hiss, R., Marrero, D. G., Walker, E. A., & Wylie-Rosett, J. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2134 · Cited by 6
Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits
Driscoll, K. A., Johnson, S. B., Wang, Y., Wright, N. A., & Deeb, L. C. (2017) · Journal of Pediatric Psychology · doi:10.1093/jpepsy/jsx151 · Cited by 8
Marsters, B. L., Styles, S. E., Galland, B. C., Wiltshire, E. J., de Bock, M. I., Tomlinson, P. A., Rayns, J. A., MacKenzie, K. E., Chan, H., & Wheeler, B. J. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13121 · Cited by 6
Sjoeholm, A., Gray, A. R., Rayns, J. A., Tomlinson, P. A., & Wheeler, B. J. (2016) · Acta Diabetologica · doi:10.1007/s00592-016-0855-z · Cited by 7
Glucose monitoring as a guide to diabetes management. Critical subject review.
Koch, B. (1996) · PubMed Central · Cited by 7
Israel, C. W., Berndt, D. J., & Barglow, P. D. (1986) · Journal of Youth and Adolescence · doi:10.1007/bf02143523 · Cited by 7
Blood Glucose Monitoring: Necessary and Sufficient?
Ginsberg, B. H. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100502 · Cited by 7
Psychological Aspects of Diabetes Mellitus in Children
Delamater, A. M. (1986) · Springer eBooks · doi:10.1007/978-1-4613-9823-3_10 · Cited by 7
Katz, L. B., Stewart, L. S., & Levy, B. L. (2015) · International Diabetes Nursing · doi:10.1179/2057332415y.0000000001 · Cited by 6
Testing versus guessing blood glucose values: impact on self-care behaviors in type 2 diabetes
Pettus, J., Stenger, P., Schachner, H. C., Dunne, N., Parkes, J. L., Pardo, S. A., & Edelman, S. V. (2014) · Current Medical Research and Opinion · doi:10.1185/03007995.2014.929097 · Cited by 6
Wojcicki, J. M. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.248 · Cited by 6
Compliance in diabetes mellitus: A self‐assessment study
Davis, T. M. E., Strong, J., & Bloom, S. R. (1988) · Practical Diabetes · doi:10.1002/pdi.1960050408 · Cited by 6
The diabetes specialist nurse: Detective and troubleshooter
Gallichan, M. (1999) · Practical Diabetes · doi:10.1002/pdi.1960160113 · Cited by 6
A Proficiency Score for Assessing the Reliability of Self Blood Glucose Monitoring
Pollard, R. H., Bridgman, J. F., North, M., & Reid, J. M. (1988) · Diabetic Medicine · doi:10.1111/j.1464-5491.1988.tb01033.x · Cited by 6
Marsters, B. L., Styles, S. E., Galland, B. C., de Lange, M., Wiltshire, E. J., de Bock, M. I., Elbalshy, M. M., Tomlinson, P. A., Rayns, J. A., MacKenzie, K. E., et al. (2020) · Acta Diabetologica · doi:10.1007/s00592-020-01556-y · Cited by 5
An Integrated Graphic Scheme for the Display of Insulin Prescription and Blood Glucose Information
Kim, M. I. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.505 · Cited by 5
Clinical Accuracy of Capillary Blood Glucose Monitoring in Hospitalized Patients with Diabetes
Bustamante, M. A., Hennessey, J. V., Teter, M. L., Stachler, R. J., & Warner, B. A. (1994) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572179402000306 · Cited by 5
Sn, W., Lai, K. P. L., Kl, C., Luk, M. H. M., Pf, C., & Chao, D. (2016) · Diabetes Management · Cited by 4
Comparison between the QRMA Measurement with the Anamnesis and the Capillary Blood Glucose Test
Muflih, M., Suwarsi, S., & Asmarani, F. L. (2020) · Jurnal NERS · doi:10.20473/jn.v14i2.6154 · Cited by 6
Khiali, S., Khezerlo-aghdam, N., Namdar, H., & Entezari‐Maleki, T. (2021) · High Blood Pressure & Cardiovascular Prevention · doi:10.1007/s40292-021-00445-x · Cited by 4
Self‐monitoring of blood glucose for type 2 diabetes
Bloomgarden, Z. T., & Ning, G. (2015) · Journal of Diabetes · doi:10.1111/1753-0407.12307 · Cited by 4
Practical Use of Self-Monitoring of Blood Glucose Data
Ginsberg, B. H. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700229 · Cited by 4
Seley, J. J. (1993) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572179301900504 · Cited by 4
Insulin Dependent Diabetes Mellitus: Regimen Adherence in Children and Young People
Reid, P., & Appleton, P. L. (1991) · The Irish Journal of Psychology · doi:10.1080/03033910.1991.10557822 · Cited by 4
COATES, V. E. (1994) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.1994.tb00399.x · Cited by 4
Diabetic Medicine diary Compiled by Johanna Tootell
(2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01026.x · Cited by 4
Shillitoe, R. (1995) · Springer eBooks · doi:10.1007/978-1-4899-3226-6_11 · Cited by 4
Driscoll, K. A., & Modi, A. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816000-8.00001-3 · Cited by 5
Initial feasibility of a researcher configurable computerized self-monitoring system
Riley, W. T., Carson, S. C., Martin, N., Behar, A., Forman‐Hoffman, V. L., & Jerome, A. (2004) · Computers in Human Behavior · doi:10.1016/j.chb.2004.02.026 · Cited by 3
Quality Assurance in Home Laboratory Testing
Keffer, J. H. (1986) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30785-6 · Cited by 3
Larson, L., & Carpenter, M. W. (2014) · Springer eBooks · doi:10.1007/978-1-4614-1244-1_4 · Cited by 3
Buzzetti, R., Bonadonna, R. C., Giaccari, A., Perseghin, G., Cucinotta, D., Fanelli, C. G., Avogaro, A., Aimaretti, G., Larosa, M., Pacchetti, I., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14560 · Cited by 3
Dukes, J. W., Chen, A. C., & Jovanovic, L. G. (2004) · Humana Press eBooks · doi:10.1007/978-1-59259-787-1_17 · Cited by 3
Practical Aspects of Intensive Insulin Therapy
Zimmerman, B. R. (1986) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)64821-6 · Cited by 3
Ahern, J. A., Bates, S., & Tamborlane, W. V. (1988) · The Science of Diabetes Self-Management and Care · doi:10.1177/014572178801400112 · Cited by 3
Self monitoring of capillary blood glucose in diabetic pregnancy
McCance, D. R., Hadden, D. R., TRAUB, A. I., & Harley, J. M. G. (1989) · Practical Diabetes · doi:10.1002/pdi.1960060210 · Cited by 3
What Is “Tight Control” of Diabetes? Goals, Limitations, and Evaluation of Therapy
Service, F. J. (1986) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)64819-8 · Cited by 3
Sanz, J., García‐Vera, M. P., & Justicia, F. J. (2000) · Psychology in Spain · Cited by 3
Self‐Monitoring of Blood Glucose in Elderly‐Diabetics: An Unaffordable Exercise in Futility?
Kabadi, U. M. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb03634.x · Cited by 2
Metadata
- Authors
- Mazze, R. S., Shamoon, H., Pasmantier, R., Lucido, D., Murphy, J., Hartmann, K., Kuykendall, V., & Lopatin, W.
- Corresponding author
- Mazze, Roger S.
- ORCID
- Shamoon, Harry
- Venue
- The American Journal of Medicine
- Publisher
- Elsevier BV
- Published
- 1984-08
- Volume
- 77
- Issue
- 2
- Pages
- 211-217
- ISSN
- 0002-9343 (ISSN-L)
- OpenAlex
- W2171957007
- Cited by
- 261
- References
- 16
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2021: 6 · 2020: 7 · 2019: 7 · 2018: 5 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 10 · 2013: 5 · 2012: 3
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- diabetes mellitus, type 1 diabetes, capillary blood glucose monitoring, self-monitoring of blood glucose, glycemic control, hypoglycemia, hyperglycemia
- MeSH terms
- Adolescent, Adult, Blood Glucose, Diabetes Mellitus, Type 1, Evaluation Studies as Topic, Female, Humans, Insulin, Male, Monitoring, Physiologic, Self Care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review