The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Artificial reductant enhancement of the Lowry method for protein determination
Open accessAbstract
Addition of dithiothreitol in the Lowry procedure 3 min after adding the Folin-Ciocalteau reagent produces immediate color development, with 35 to 60% greater absorbance per mass of protein used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Markwell, M. A. K., Haas, S. M., Bieber, L. L., & Tolbert, N. E. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90586-9 · Cited by 6,458
Assay of proteins in the presence of interfering materials
Bensadoun, A., & Weinstein, D. (1976) · Analytical Biochemistry · doi:10.1016/s0003-2697(76)80064-4 · Cited by 3,179
ON TYROSINE AND TRYPTOPHANE DETERMINATIONS IN PROTEINS
Folin, O., & Ciocalteu, V. (1927) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)84277-6 · Cited by 2,946
A simplified method of quantitating protein using the biuret and phenol reagents
Ohnishi, S. T., & Barr, J. K. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90334-2 · Cited by 453
On the chemical basis of the Lowry protein determination
Legler, G., Müller‐Platz, C., Mentges-Hettkamp, M., Pflieger, G., & Jülich, E. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90511-1 · Cited by 80
Cited by
Singleton, V. L., Orthofer, R., & Lamuela-Raventós, R. M. (1999) · Methods in Enzymology · doi:10.1016/s0076-6879(99)99017-1 · Cited by 19,125
Stoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438
Glycine receptor heterogeneity in rat spinal cord during postnatal development.
Becker, C. M., Hoch, W., & Betz, H. (1988) · The EMBO Journal · doi:10.1002/j.1460-2075.1988.tb03255.x · Cited by 378
Monoclonal Antibodies to the Alternative Oxidase of Higher Plant Mitochondria
Elthon, T. E., Nickels, R. L., & McIntosh, L. (1989) · Plant Physiology · doi:10.1104/pp.89.4.1311 · Cited by 339
Pribilla, I., Takagi, T., Langosch, D., Bormann, J., & Betz, H. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06404.x · Cited by 336
Metadata
- Authors
- Larson, E., Howlett, B., & Jagendorf, A.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1986-06
- Volume
- 155
- Issue
- 2
- Pages
- 243-248
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W1989947655
- Cited by
- 331
- References
- 6
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial reductant enhancement of the Lowry method for protein determination. https://app.cochat.ai/papers/10.1016/0003-2697(86)90432-x
- The paper
- Larson, E., Howlett, B., & Jagendorf, A. (1986). Artificial reductant enhancement of the Lowry method for protein determination. Analytical Biochemistry. https://doi.org/10.1016/0003-2697(86)90432-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.