Calculation of protein extinction coefficients from amino acid sequence data
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Bradford, M. M. (1976) · Analytical Biochemistry · doi:10.1016/0003-2697(76)90527-3 · Cited by 255,302
Spectroscopic Determination of Tryptophan and Tyrosine in Proteins*
Edelhoch, H. (1967) · Biochemistry · doi:10.1021/bi00859a010 · Cited by 3,436
Ultraviolet Absorption Spectra of Proteins and Amino Acids
Beaven, G. H., & Holiday, E. R. (1952) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60022-4 · Cited by 1,113
Measurement of protein by spectrophotometry at 205 nm
Scopes, R. K. (1974) · Analytical Biochemistry · doi:10.1016/0003-2697(74)90034-7 · Cited by 760
An absolute method for protein determination based on difference in absorbance at 235 and 280 nm
Whitaker, J. R., & Granum, P. E. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90024-x · Cited by 598
ISOLATION AND PROPERTIES OF A PURE YEAST POLYPEPTIDASE
Johnson, M. J. (1941) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)56163-4 · Cited by 552
Butler, A. P., Revzin, A., & von Hippel, P. H. (1977) · Biochemistry · doi:10.1021/bi00641a001 · Cited by 95
Cited by
Protein Identification and Analysis Tools on the ExPASy Server
Gasteiger, E., Hoogland, C., Gattiker, A., Duvaud, S., Wilkins, M. R., Appel, R. D., & Bairoch, A. (2005) · The Proteomics Protocols Handbook · doi:10.1385/1-59259-890-0:571 · Cited by 8,681
Protein Identification and Analysis Tools in the ExPASy Server
Wilkins, M. R., Gasteiger, E., Bairoch, A., Sanchez, J.-C., Williams, K. L., Appel, R. D., & Hochstrasser, D. F. (2003) · 2-D Proteome Analysis Protocols · doi:10.1385/1-59259-584-7:531 · Cited by 6,155
How to measure and predict the molar absorption coefficient of a protein
Pace, C. N., Vajdos, F., Fee, L., Grimsley, G., & Gray, T. (1995) · Protein Science · doi:10.1002/pro.5560041120 · Cited by 3,907
How to study proteins by circular dichroism
Kelly, S. M., Jess, T. J., & Price, N. C. (2005) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2005.06.005 · Cited by 3,351
Dinkova-Kostova, A. T., Holtzclaw, W. D., Cole, R. N., Itoh, K., Wakabayashi, N., Katoh, Y., Yamamoto, M., & Talalay, P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172398899 · Cited by 1,947
Metadata
- Authors
- Gill, S. C., & von Hippel, P. H.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1989-11
- Volume
- 182
- Issue
- 2
- Pages
- 319-326
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2005986251
- Cited by
- 5,283
- References
- 8
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.