Storage of natural gas by adsorption on activated carbon
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Natural gas may be stored by liquefaction, compression, or adsorption. For use as a transportation fuel, liquefaction is impractical and compression requires high pressure (20 MPa) and an expensive multi-stage compression facility. At relatively low pressure (3–4 MPa) achievable by single-stage compression, adsorbed natural gas (ANG) has nearly the capacity of compressed natural gas (CNG). Monte Carlo calculations were performed to simulate the adsorption of natural gas on activated carbon. The model is pure methane intercalated between parallel planes of graphite at a slit of width 11.4 Å, optimized for ANG storage. The simulations predict that the maximum delivered energy density of ANG is 0.25 for monolithic carbon and 0.17 for pelletized carbon, compared to 0.29 for CNG and 1.0 for gasoline.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reich, R., Ziegler, W. T., & Rogers, K. A. (1980) · Industrial & Engineering Chemistry Process Design and Development · doi:10.1021/i260075a002 · Cited by 214
Costa, E., Sotelo, J. L., Calleja, G., & Marrón, C. (1981) · AIChE Journal · doi:10.1002/aic.690270103 · Cited by 177
Equilibrium adsorption of multicomponent gas mixtures at elevated pressures
Ritter, J. A., & Yang, R. T. (1987) · Industrial & Engineering Chemistry Research · doi:10.1021/ie00068a032 · Cited by 108
A modern version of volumetric apparatus for measuring gas-solid equilibrium data
Kaul, B. K. (1987) · Industrial & Engineering Chemistry Research · doi:10.1021/ie00065a013 · Cited by 50
Tokunaga, N., Oshiyama, H., Nitta, T., & Katayama, T. (1988) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.21.431 · Cited by 16
Cited by
Functional Porous Coordination Polymers
Kitagawa, S., Kitaura, R., & Noro, S. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300610 · Cited by 11,071
Furukawa, H., & Yaghi, O. M. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9015765 · Cited by 2,608
Funktionale poröse Koordinationspolymere
Kitagawa, S., Kitaura, R., & Noro, S. (2004) · Angewandte Chemie · doi:10.1002/ange.200300610 · Cited by 1,348
Evaluating metal–organic frameworks for natural gas storage
Mason, J. A., Veenstra, M., & Long, J. R. (2014) · Chem. Sci. · doi:10.1039/c3sc52633j · Cited by 1,239
Optimum Conditions for Adsorptive Storage
Bhatia, S. K., & Myers, A. L. (2006) · Langmuir · doi:10.1021/la0523816 · Cited by 1,113
Self-citation
Metadata
- Authors
- Matranga, K. R., Myers, A. L., & Glandt, E. D.
- Venue
- Chemical Engineering Science
- Publisher
- Elsevier BV
- Published
- 1992-05
- Volume
- 47
- Issue
- 7
- Pages
- 1569-1579
- ISSN
- 0009-2509 (ISSN-L)
- OpenAlex
- W2087069532
- Cited by
- 389
- References
- 5
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.