The DOI matches its Crossref record.
Thermal conductivity of some insulating materials materials below 1 K
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Locatelli et al. [9] and Olson [12] have previously reported the low-temperature thermal conductivity of Vespel SP-1 (up to 1 K) and SP-22 (up to 2 K).
“Locatelli et al. [9] and Olson [12] have previously reported the low-temperature thermal conductivity of Vespel SP-1 (up to 1 K) and SP-22 (up to 2 K).”
From Thermal conductivity of thermally-isolating polymeric and composite structural support materials between 0.3 and 4K (2008) · cites this paper as [9]
Locatelli et al. [9] measured SP-1 from 0.1 to 1 K and we agree with the shallow index of 1.1-1.2 across this temperature range.
“Locatelli et al. [9] measured SP-1 from 0.1 to 1 K and we agree with the shallow index of 1.1-1.2 across this temperature range.”
From Thermal conductivity of thermally-isolating polymeric and composite structural support materials between 0.3 and 4K (2008) · cites this paper as [9]
Citations
Cites
No references could be resolved yet.
Cited by
Sorted by citations
Runyan, M. C., & Jones, W. C. (2008) · Cryogenics · doi:10.1016/j.cryogenics.2008.06.002 · Cited by 47
Metadata
- Authors
- Locatelli, M., Arnaud, D., & Routin, M.
- Affiliations
- CEA Grenoble (FR)
- Venue
- Cryogenics
- Publisher
- Elsevier BV
- Published
- 1976-06
- Volume
- 16
- Issue
- 6
- Pages
- 374-375
- ISSN
- 0011-2275 (ISSN-L)
- OpenAlex
- W2089902231
- Cited by
- 44
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 2 · 2020: 1 · 2016: 1 · 2014: 2
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Cryogenics (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Thermodynamic Systems and Engines
- Keywords
- thermal conductivity, sintered alumina, pulse tube refrigerator, heat leakage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review