Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
The DOI matches its Crossref record; 49 of the 54 references it cites were found in a registry or an index.
Abstract
The paper describes a new algorithm for tomographic source reconstruction in neural electromagnetic inverse problems. Termed FOCUSS (FOCal Underdetermined System Solution), this algorithm combines the desired features of the two major approaches to electromagnetic inverse procedures. Like multiple current dipole modeling methods, FOCUSS produces high resolution solutions appropriate for the highly localized sources often encountered in electromagnetic imaging. Like linear estimation methods, FOCUSS allows current sources to assume arbitrary shapes and it preserves the generality and ease of application characteristic of this group of methods. It stands apart from standard signal processing techniques because, as an initialization-dependent algorithm, it accommodates the non-unique set of feasible solutions that arise from the neuroelectric source constraints. FOCUSS is based on recursive, weighted norm minimization. The consequence of the repeated weighting procedure is, in effect, to concentrate the solution in the minimal active regions that are essential for accurately reproducing the measurements. The FOCUSS algorithm is introduced and its properties are illustrated in the context of a number of simulations, first using exact measurements in 2- and 3-D problems, and then in the presence of noise and modeling errors. The results suggest that FOCUSS is a powerful algorithm with considerable utility for tomographic current estimation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sparsity is often assumed to avoid over-fitting in inverse problems, and has increasing applications in signal and image processing (43, 50–54).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [50]
In the citing paper
“FOCal Underdetermined System Solution (FOCUSS) (50), is an early example of using sparsity for ESI.”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [50]
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Singular value decomposition and least squares solutions
Golub, G. H., & Reinsch, C. (1970) · Numerische Mathematik · doi:10.1007/bf02163027 · Cited by 2,929
Solving Least Squares Problems.
Ling, R. F., Lawson, C. L., & Hanson, R. J. (1977) · Journal of the American Statistical Association · doi:10.2307/2286501 · Cited by 2,723
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003 · cited 1×
“Dale and Sereno (1993) proposed a hybrid method that uses a solution from a dipole estimation procedure to determine weights for a weighted pseudo-inverse solution.”
MethodInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
REGULARIZATION OF INCORRECTLY POSED PROBLEMS
Tikhonov, A. N. (1963) · Cited by 876
Neural Networks and Natural Intelligence
(1988) · The MIT Press eBooks · doi:10.7551/mitpress/4934.001.0001 · Cited by 720
Evoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
Considerations of quasi-stationarity in electrophysiological systems
Plonsey, R., & Heppner, D. B. (1967) · The Bulletin of Mathematical Biophysics · doi:10.1007/bf02476917 · Cited by 619
Fundamentals if dipole source potential analysis
Scherg, M. (1990) · Max Planck Institute for Plasma Physics · Cited by 530
Hansen, P. C. (1990) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0911028 · Cited by 507
Using a magnetometer to image a two-dimensional current distribution
Roth, B. J., Sepulveda, N. G., & Wikswo, J. P. (1989) · Journal of Applied Physics · doi:10.1063/1.342549 · Cited by 462
(1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1 · Cited by 452
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Continuous probabilistic solutions to the biomagnetic inverse problem
Ioannides, A. A., Bolton, J. P. R., & Clarke, C. J. S. (1990) · Inverse Problems · doi:10.1088/0266-5611/6/4/005 · Cited by 294
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650702 · Cited by 268
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
Wood, C. C., & McCarthy, G. (1984) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(84)90064-9 · Cited by 216
An Application of the Wiener-Kolmogorov Smoothing Theory to Matrix Inversion
Foster, M. R. (1961) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0109031 · Cited by 162
Supek, S., & Aine, C. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237672 · Cited by 153
Effects of head shape on EEGs and MEGs
Cuffin, B. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43614 · Cited by 153
The localization of equivalent dipoles of EEG sources by the application of electrical field theory
Henderson, C. J., Butler, S. R., & Glass, A. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90002-4 · Cited by 150
Beyond topographic mapping: Towards functional-anatomical imaging with 124-channel EEGs and 3-D MRIs
Gevins, A. S., Brickett, P., Costales, B., Le, J., & Reutter, B. W. (1990) · Brain Topography · doi:10.1007/bf01128862 · Cited by 145
Pantev, C., Hoke, M., Lehnertz, K., Lütkenhöner, B., Fahrendorf, G., & Stöber, U. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90171-f · Cited by 137
Extrapolation and spectral estimation with iterative weighted norm modification
Cabrera, S. D., & Parks, T. W. (1991) · IEEE Transactions on Signal Processing · doi:10.1109/78.80906 · Cited by 105
Methods for separating temporally overlapping sources of neuroelectric data
Achim, A., Richer, F., & Saint-Hilaire, J. M. (1988) · Brain Topography · doi:10.1007/bf01129336 · Cited by 83
Methodological considerations for the evaluation of spatio-temporal source models
Achim, A., Richer, F., & Saint-Hilaire, J. M. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90140-y · Cited by 77
A method for localization of sources of human cerebral potentials evoked by sensory stimuli.
Sidman, R. D., Giambalvo, V., Allison, T., & Bergey, P. D. (1978) · PubMed · Cited by 66
Dipole source localization in the study of EP generators: a critique
Snyder, A. Z. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90116-f · Cited by 62
Adaptive filters for monitoring localized brain activity from surface potential time series
Spencer, M. E., Leahy, R. M., Mosher, J. C., & Lewis, P. S. (2003) · [1992] Conference Record of the Twenty-Sixth Asilomar Conference on Signals, Systems & Computers · doi:10.1109/acssc.1992.269278 · Cited by 55
Neuromagnetic functional localization: principles, state of the art, and perspectives
Romani, G. L., & Rossini, P. (1988) · Brain Topography · doi:10.1007/bf01129335 · Cited by 51
Reconstruction of Images from Neuromagnetic Fields
Singh, M., Doria, D., Henderson, V. W., Huth, G. C., & Beatty, J. (1984) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1984.4333324 · Cited by 49
Monte Carlo Analysis of Localization Errors in Magnetoencephalography
Medvick, P. A., Lewis, P. S., Aine, C. J., & Flynn, E. R. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_118 · Cited by 38
Linear estimation theory applied to the reconstruction of a 3-D vector current distribution
Smith, W. E., Dallas, W. J., Kullmann, W. H., & Schlitt, H. A. (1990) · Applied Optics · doi:10.1364/ao.29.000658 · Cited by 33
Anatomical constraints for neuromagnetic source models
George, J., Lewis, P. S., Ranken, D. M., Kaplan, L., & Wood, C. C. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.43427 · Cited by 33
Self-citationA new iterative weighted norm minimization algorithm and its applications
Gorodnitsky, I. F., & Rao, B. D. (2003) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssap.1992.246872 · Cited by 29
Self-citationImprovement of discrete band-limited signal extrapolation by iterative subspace modification
Lee, H., Sullivan, D., & Huang, T. S. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1987.1169486 · Cited by 28
A Linear Estimation Approach to Biomagnetic Imaging
Kullmann, W., Jandt, K. D., Rehm, K., Schlitt, H. A., Dallas, W. J., & Smith, W. E. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_125 · Cited by 27
Sano, A. (1993) · Signal Processing · doi:10.1016/0165-1684(93)90145-z · Cited by 26
Extracorporeal magnetic fields generated by internal bioelectric sources
Geselowitz, D. A., & Miller, W. (1973) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1973.1067660 · Cited by 21
Minimum Norm Estimation of Current Distributions in Realistic Geometries
Crowley, C. W., Greenblatt, R. E., & Khalil, I. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_133 · Cited by 20
A recursive weighted minimum norm algorithm: Analysis and applications
Gorodnitsky, I. F., & Rao, B. D. (1993) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1993.319533 · Cited by 20
Self-citationStrategies for source space limitation in tomographic inverse procedures
George, J., Lewis, P. S., Schlitt, H. A., Kaplan, L., Gorodnitsky, I. F., & Wood, C. C. (1994) · University of North Texas Digital Library (University of North Texas) · Cited by 8
Self-citationConvergence analysis of a class of adaptive weighted norm extrapolation algorithms
Gorodnitsky, I. F., & Rao, B. D. (2002) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.1993.342530 · Cited by 5
Self-citationThird swiss EEG-EP mapping meeting
Brandeis, D., & Michel, C. M. (1990) · Brain Topography · doi:10.1007/bf01135444 · Cited by 3
Truncated Total Least Squares Regularization Underdetermined Problems
Gorodnitsky, I. F., & Rao, B. D. (2005) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssap.1994.572422 · Cited by 2
Self-citation
Research works printed but not linked: 3
- Gorodnitsky, 1994, Analysis of regularization error in Tikhonov regularization and truncated singular value decomposition methods, Vol. 1
- Gorodnitsky, 1992, Weighted linear estimator procedures for neuromagnetic source reconstruction, J. Neuroimaging, 1, 54
- Van Veen, 1992, Localization of intracerebral sources of elecrical activity via linearly constrained minimum variance spatial filtering, Vol. 1, 157
Cited by
Iterative hard thresholding for compressed sensing
Blumensath, T., & Davies, M. E. (2009) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2009.04.002 · Cited by 2,275
Sparse signal reconstruction from limited data using FOCUSS: a re-weighted minimum norm algorithm
Gorodnitsky, I. F., & Rao, B. D. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.558475 · Cited by 1,834
Self-citationBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Sparse Bayesian Learning for Basis Selection
Wipf, D. P., & Rao, B. D. (2004) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2004.831016 · Cited by 1,559
“Example applications include biomagnetic imaging [4], channel equalization [5]–[7], bandlimited extrapolation and spectral estimation [8], [9], direction-of-arrival estimation [10], functional approximation [11]–[13], echo cancellation [14], [15], and image restoration [16].”
BackgroundSelf-citation
Metadata
- Authors
- Gorodnitsky, I. F., George, J. S., & Rao, B. D.
- Affiliations
- University of California San Diego (US)
- Los Alamos National Laboratory (US)
- Corresponding author
- Gorodnitsky, Irina F.
- ORCID
- Rao, Bhaskar D.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1995-10
- Volume
- 95
- Issue
- 4
- Pages
- 231-251
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2065919982
- Cited by
- 567
- References
- 54
- Citations by year
- 2026: 1 · 2025: 15 · 2024: 10 · 2023: 12 · 2022: 14 · 2021: 18 · 2020: 26 · 2019: 12 · 2018: 19 · 2017: 28 · 2016: 20 · 2015: 34 · 2014: 19 · 2013: 22 · 2012: 20
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ey008610-10)
- National Eye Institute (EY08610)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Keywords
- FOCUSS, electromagnetic inverse problems, linear estimation, underdetermined systems, source localization
- MeSH terms
- Algorithms, Brain Mapping, Humans, Image Processing, Computer-Assisted, Models, Neurological, Magnetoencephalography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.