Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 915

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Enhanced autoradiographic detection of 32P and 125I using intensifying screens and hypersensitized film

Laskey, Ronald A., Mills, Anthony D.·1977·FEBS Letters

Abstract

This paper reports that autoradiographic sensitivity can be greatly increased for isotopes which emit y rays (e.g., ‘251) or high energy p particles (e.g., 32P) by placing a pre-exposed film between the sample and a calcium tungstate (CaW04) X-ray intensifying screen and exposing at --70°C. The combination of preexposed Kodak X-OMAT R film with either a Fuji Mach 2 screen or a Du Pont Lightning Plus screen at -70°C enhances detection efficiency 1 OS-fold for 32P and 16-fold for “‘1 when compared to conventional autoradiography on Kodirex film. The method is applicable to wet or dry gels, to chromatograms on paper or thin layer plates, or to nitrocellulose filters. Emissions from the sample pass through the film producing a direct autoradiographic image. Emissions which pass completely through and beyond the film are absorbed more efficiently by the screen where they produce multiple photons of visible light which return through the film superimposing a photographic image over the autoradiographic image. Although intensifying screens are used routinely in medical radiography [2] , their use for the much longer exposures used in biochemical autoradiography depends on by-passing the initial reversible stage of latent image formation [3]. As explained previously this problem can be overcome by lowering the temperature to -70°C [ 1,4] and hypersensitizing the film by pre-exposing it to an instantaneous (1 ms) flash of light [ 11 . Neither preexposure nor exposure at low temperature increases the efficiency of conventional direct autoradiography. We shall refer to the method described in this paper as indirect autoradiography. It is unsuitable for isotopes which emit lowenergy p particles such as 3H, i4C or 35S.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0014-5793(77)80609-1

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 915

Metadata

Authors
Laskey, R. A., & Mills, A. D.
Venue
FEBS Letters
Publisher
Wiley
Published
1977-10-15
Volume
82
Issue
2
Pages
314-316
ISSN
  • 0014-5793 (ISSN-L)
  • 1873-3468
OpenAlex
W2062147146
Cited by
915
References
3
FWCI
87.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced autoradiographic detection of 32P and 125I using intensifying screens and hypersensitized film. https://app.cochat.ai/papers/10.1016/0014-5793(77)80609-1
The paper
Laskey, R. A., & Mills, A. D. (1977). Enhanced autoradiographic detection of 32P and 125I using intensifying screens and hypersensitized film. FEBS Letters. https://doi.org/10.1016/0014-5793(77)80609-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.