The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
The nonlinear characteristics of soft gels and hydrated connective tissues in ultrafiltration
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Non-Linear Field Theories of Mechanics
Truesdell, C., & Noll, W. (1965) · Encyclopedia of Physics / Handbuch der Physik · doi:10.1007/978-3-642-46015-9_1 · Cited by 3,365
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Self-citationLerner, R. G., & Trigg, G. L. (1991) · Cited by 1,153
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationSpectrum of light scattered from a viscoelastic gel
Tanaka, T., Hocker, L. O., & Benedek, G. B. (1973) · The Journal of Chemical Physics · doi:10.1063/1.1680734 · Cited by 747
THE PERMEABILITY OF ARTICULAR CARTILAGE
Maroudas, A., Bullough, P., Swanson, S. A. V., & Freeman, M. A. R. (1968) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.50b1.166 · Cited by 350
Brent, B. (1981) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198101000-00023 · Cited by 339
Drag-induced compression of articular cartilage during a permeation experiment1
Lai, W. M., & Mow, V. C. (1980) · Biorheology · doi:10.3233/bir-1980-171-213 · Cited by 321
Self-citationLateral compressibility of lipid mono- and bilayers. Theory of membrane permeability
Nagle, J. F., & Scott, H. L. (1978) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(78)90176-1 · Cited by 248
Electromechanical and physicochemical properties of connective tissue.
Grodzinsky, A. J. (1983) · PubMed · Cited by 247
Cited by
Giverso, C., & Preziosi, L. (2019) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2018.10.005 · Cited by 27
Computational aspects in mechanical modeling of the articular cartilage tissue
Mohammadi, H., Mequanint, K., & Herzog, W. (2013) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411912470239 · Cited by 28
Metadata
- Authors
- Holmes, M. H., & Mow, V. C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 23
- Issue
- 11
- Pages
- 1145-1156
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2020837715
- Cited by
- 458
- References
- 17
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The nonlinear characteristics of soft gels and hydrated connective tissues in ultrafiltration. https://app.cochat.ai/papers/10.1016/0021-9290(90)90007-p
- The paper
- Holmes, M. H., & Mow, V. C. (1990). The nonlinear characteristics of soft gels and hydrated connective tissues in ultrafiltration. Journal of Biomechanics. https://doi.org/10.1016/0021-9290(90)90007-p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.