A microstructurally-based finite element model of the incised human cornea
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A mechanical model of the human cornea is proposed and employed in a finite element formulation for simulating the effects of surgical procedures, such as radial keratotomy, on the cornea. The model assumes that the structural behavior of the cornea is governed by the properties of the stroma. Arguments based on the microstructural organization and properties of the stroma lead to the conclusion that the human cornea exhibits flexural and shear rigidities which are negligible compared to its membrane rigidity. Accordingly, it is proposed that to a first approximation, the structural behavior of the cornea is that of a thick membrane shell. The tensile forces in the cornea are resisted by very fine collagen fibrils embedded in the ground substance of the stromal lamellae. When the collagen fibrils are cut, as in radial keratotomy, it is argued that they become relaxed since there is negligible transfer of load between adjacent fibrils due to the low shear modulus of the ground substance. The forces in the cornea are then resisted only by the remaining uncut fibrils. The cutting of fibrils induces an anisotropy and inhomogeneity in the membrane rigidity. By assuming a uniform angular distribution of stromal lamellae through the corneal thickness, geometric arguments lead to a quantitative representation for the anisotropy and inhomogeneity. All material behavior is assumed to be in the linear elastic regime and with no time-dependency. The resulting constitutive model for the incised cornea has been employed in a geometrically non-linear finite element membrane shell formulation for small strains with moderate rotations. A number of numerical examples are presented to illustrate the effectiveness of the proposed constitutive model and finite element formulation. The dependence of the outcome of radial keratotomy, measured in terms of the immediate postoperative shift in corneal power, on a number of important factors is investigated. These factors include the value of the elastic moduli of the stromal lamellae (dependent on the patient's age), the incision depth, the optic zone size, the number of incisions and their positions, and the intraocular pressure. Results have also been compared with expected surgical corrections predicted by three expert surgeons and show an excellent correspondence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MAURICE, D. M. (1962) · Vegetative Physiology and Biochemistry · doi:10.1016/b978-1-4832-3090-0.50013-7 · Cited by 436
Nonlinear material properties of intact cornea and sclera
Woo, S. L., KOBAYASHI, A. S., Schlegel, W. A., & Lawrence, C. (1972) · Experimental Eye Research · doi:10.1016/0014-4835(72)90139-x · Cited by 345
The mechanical properties of the rabbit and human cornea
Jue, B., & Maurice, D. M. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90135-1 · Cited by 222
Finite Elements In Biomechanics
Gallagher, R. H., SIMON, B. R., Johnson, P. C., & Gross, J. F. (1982) · Journal of Clinical Engineering · doi:10.1097/00004669-198207000-00019 · Cited by 132
Rheology of the cornea: Experimental techniques and results
Nyquist, G. W. (1968) · Experimental Eye Research · doi:10.1016/s0014-4835(68)80064-8 · Cited by 112
Striations of light scattering in the corneal stroma
Gallagher, B. C., & Maurice, D. M. (1977) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(77)90009-0 · Cited by 53
Cited by
Biomechanics and wound healing in the cornea
Dupps, W. J., & Wilson, S. E. (2006) · Experimental Eye Research · doi:10.1016/j.exer.2006.03.015 · Cited by 510
A comparison of biomechanical properties between human and porcine cornea
Zeng, Y., Yang, J., Huang, K., Lee, Z., & Lee, X. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00219-0 · Cited by 316
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Meek, K. M., & Boote, C. (2009) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.06.005 · Cited by 247
Pandolfi, A., & Holzapfel, G. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2982251 · Cited by 245
Metadata
- Authors
- Pinsky, P. M., & Datye, D. V.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1991
- Volume
- 24
- Issue
- 10
- Pages
- 907-922
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2018661992
- Cited by
- 159
- References
- 6
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.