Trabecular bone modulus and strength can depend on specimen geometry
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Self-citationLimitations of the continuum assumption in cancellous bone
Harrigan, T. P., Jasty, M., Mann, R. W., & Harris, W. H. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90257-6 · Cited by 305
Mechanical Property Distributions in the Cancellous Bone of the Human Proximal Femur
Brown, T. D., & Ferguson, A. B. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990819 · Cited by 282
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233
The underestimation of Young's modulus in compressive testing of cancellous bone specimens
Odgaard, A., & Linde, F. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90333-i · Cited by 225
Anatomical variation of orthotropic elastic moduli of the proximal human tibia
Ashman, R. B., Rho, J. Y., & Turner, C. H. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90073-0 · Cited by 184
The effect of constraint on the mechanical behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90209-1 · Cited by 181
Theoretical analysis of the experimental artifact in trabecular bone compressive modulus
Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90021-6 · Cited by 136
Self-citationYield Behavior of Bovine Cancellous Bone
Turner, C. H. (1989) · Journal of Biomechanical Engineering · doi:10.1115/1.3168375 · Cited by 127
Stiffness behaviour of trabecular bone specimens
Linde, F., & Hvid, I. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90270-3 · Cited by 89
Compressive axial strain distributions in cancellous bone specimens
Odgaard, A., Hvid, I., & Linde, F. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90066-3 · Cited by 86
Cited by
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationThree-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationMajumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331
Metadata
- Authors
- Keaveny, T. M., Borchers, R. E., Gibson, L. J., & Hayes, W. C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-08
- Volume
- 26
- Issue
- 8
- Pages
- 991-1000
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2010115468
- Cited by
- 160
- References
- 11
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.