The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Flow-through particles for the high-performance liquid chromatographic separation of biomolecules: perfusion chromatography
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography
van Deemter, J. J., Zuiderweg, F. J., & Klinkenberg, A. (1956) · Chemical Engineering Science · doi:10.1016/0009-2509(56)80003-1 · Cited by 1,698
A new form of chromatogram employing two liquid phases
Martin, A. J. P., & Synge, R. L. M. (1941) · Biochemical Journal · doi:10.1042/bj0351358 · Cited by 1,631
Chromatography of Proteins. I. Cellulose Ion-exchange Adsorbents
Peterson, E. A., & Sober, H. A. (1956) · Journal of the American Chemical Society · doi:10.1021/ja01585a016 · Cited by 1,277
Stofftransport und Stoffverteilung bei chromatographischen Prozessen
Huber, J. F. K. (1973) · Berichte der Bunsengesellschaft für physikalische Chemie · doi:10.1002/bbpc.19730770308 · Cited by 75
Mass transfer phenomena in gel permeation chromatography
Kreveld, M. E. V., & Hoed, N. V. D. (1978) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)80979-6 · Cited by 65
Non uniform enzyme distribution inside carriers
Buchholz, K. (1979) · Biotechnology Letters · doi:10.1007/bf01388425 · Cited by 20
Enzyme immobilization in porous solid supports—penetration of immobilized enzyme
Do, D. D. (1984) · Biotechnology and Bioengineering · doi:10.1002/bit.260260904 · Cited by 11
Cited by
Continuous rods of macroporous polymer as high-performance liquid chromatography separation media
Svec, F., & Frechet, J. M. J. (1992) · Analytical Chemistry · doi:10.1021/ac00031a022 · Cited by 951
Octadecylsilylated Porous Silica Rods as Separation Media for Reversed-Phase Liquid Chromatography
Minakuchi, H., Nakanishi, K., Soga, N., Ishizuka, N., & Tanaka, N. (1996) · Analytical Chemistry · doi:10.1021/ac960281m · Cited by 904
Monolithic columns in high-performance liquid chromatography
Guiochon, G. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.090 · Cited by 831
New Designs of Macroporous Polymers and Supports: From Separation to Biocatalysis
Svec, F., & Fréchet, J. M. J. (1996) · Science · doi:10.1126/science.273.5272.205 · Cited by 586
Trinidad, J. C., Barkan, D. T., Gulledge, B. F., Thalhammer, A., Sali, A., Schoepfer, R., & Burlingame, A. L. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.018366 · Cited by 424
Metadata
- Authors
- Afeyan, N. B., Gordon, N. F., Mazsaroff, I., Varady, L., Fulton, S. P., Yang, Y. B., & Regnier, F. E.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 1990-10
- Volume
- 519
- Issue
- 1
- Pages
- 1-29
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2092080320
- Cited by
- 528
- References
- 7
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow-through particles for the high-performance liquid chromatographic separation of biomolecules: perfusion chromatography. https://app.cochat.ai/papers/10.1016/0021-9673(90)85132-f
- The paper
- Afeyan, N. B., Gordon, N. F., Mazsaroff, I., Varady, L., Fulton, S. P., Yang, Y. B., & Regnier, F. E. (1990). Flow-through particles for the high-performance liquid chromatographic separation of biomolecules: perfusion chromatography. Journal of Chromatography A. https://doi.org/10.1016/0021-9673(90)85132-f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.