Abstract
High resolution body surface potential maps (BSPM) and magnetic field maps (MFM) for study groups consisting of 11 Q wave and 11 non Q wave myocardial infarct (MI) patients as well as 9 normal subjects, were recorded in a magnetically and electrically shielded room. A control group of 22 normal subjects provided group mean normal time integral maps for selected QRST time intervals. The difference between magnitudes of extrema in each map defined the normal mean data range R for that time interval. The root mean square sum of the differences between the time integral map of a study subject and the normal group-mean map provided an estimate of individual map variability, V. Subsequent calculation of group-mean map variability, V, and group-mean normalized variability, V/R, for specific time intervals of the cardiac cycle, were used to test the abilities of BSPM and MFM techniques to distinguish between the normal and MI study groups. Results indicate that BSPM V/R differences between MI and normal groups are most pronounced during Q wave and Q zone activity; between inferior MI's and normals (p less than 0.05) and between anterior MI's and normal (p less than 0.01). Significant differences in MFM V/R occur during repolarization; between inferior MI's and non Q wave MI's (p less than 0.05), between anterior MI's and normals (p less than 0.05), between non Q wave MI's and normals (p less than 0.05) and between all MI's and normals (p less than 0.01). It is concluded that high resolution BSPM and MFM provide complementary means of discriminating between normal subjects and MI patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because the MCG is more sensitive to tangential cardiac currents and circular vortex currents and the ECG is more sensitive to the radial currents in principle (1, 17, 18), it is believed that the exercise MCG (eMCG) contains information complementary to the eECG (19, 20) and shows a better sensitivity to the deviations from the normal activation direction (21, 22).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [19]
In the citing paper
“a foundational research from the general theory of bioelectromagnetism describes the amount of potential additional information provided by MCG (1–7)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [6]
In the citing paper
“although theory and experimental research suggest and confirm that it can provide additional diagnostic information not achievable with electrocardiography alone (1, 2, 4–6, 9, 16, 107).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [6]
Citations
Cites
Montague, T. J., Smith, E. R., Cameron, D. A., Rautaharju, P. M., Klassen, G. A., Felmington, C. S., & Horacek, B. M. (1981) · Circulation · doi:10.1161/01.cir.63.5.1166 · Cited by 178
Self-citationBiomagnetism. An interdisciplinary approach
Hughes, J. R. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90180-9 · Cited by 146
Quantitative analysis of myocardial infarct structure in patients with ventricular tachycardia.
Bolick, D. R., Hackel, D. B., Reimer, K. A., & Ideker, R. E. (1986) · Circulation · doi:10.1161/01.cir.74.6.1266 · Cited by 113
Body Surface Electrocardiographic Mapping
Mirvis, D. M. (1988) · Developments in cardiovascular medicine · doi:10.1007/978-1-4613-1769-2 · Cited by 62
Montague, T. J., Smith, E. R., Spencer, C., Johnstone, D. E., Lalonde, L. D., Bessoudo, R., Gardner, M. J., Anderson, R. N., & Horáček, B. M. (1983) · Circulation · doi:10.1161/01.cir.67.3.665 · Cited by 58
Self-citationQ wave, S-T segment, and T wave myocardial infarction. Useful clinical distinction
Zema, M. J. (1985) · The American Journal of Medicine · doi:10.1016/0002-9343(85)90329-8 · Cited by 39
Non-Q-wave acute myocardial infarction: Body surface potential map and ventriculographic patterns
Montague, T. J., Johnstone, D. E., Spencer, C., Lalonde, L. D., Gardner, M. J., O’Reilly, M. G., & Horáček, B. M. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90377-2 · Cited by 39
Self-citationEffect of torso boundaries on electric potential and magnetic field of a dipole
Purcell, C., Stroink, G., & Horáček, B. M. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7268 · Cited by 36
Self-citationComparative study of the normal vector magnetocardiogram and vector electrocardiogram
Nousiainen, J., Tech, Lekkala, J. O., Tech, & Malmivuo, J. A. (1986) · Journal of Electrocardiology · doi:10.1016/s0022-0736(86)80037-1 · Cited by 19
Electrocardiographic and ventriculographic recovery patterns in Q wave myocardial infarction
Montague, T. J., McPherson, D. D., Johnstone, D. E., Spencer, C., Lalonde, L. D., Gardner, M. J., & Horáček, B. M. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80178-4 · Cited by 17
Self-citation
Research works printed but not linked: 1
- Cohen, 1976, Abnormal patterns and physiologic variation in MCG, J Electrophysiology, 9, 398
Cited by
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Preprocessing and Denoising Techniques for Electrocardiography and Magnetocardiography: A Review
Jia, Y., Pei, H., Liang, J., Zhou, Y., Yang, Y., Cui, Y., & Xiang, M. (2024) · Bioengineering · doi:10.3390/bioengineering11111109 · Cited by 92
Metadata
- Authors
- Lant, J., Stroink, G., ten Voorde, B., Horacek, B. M., & Montague, T. J.
- Affiliations
- Dalhousie University (CA)
- Corresponding author
- Stroink, Gerhard
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 1990-10
- Volume
- 23
- Issue
- 4
- Pages
- 315-322
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2028415099
- Cited by
- 63
- References
- 12
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 5 · 2021: 1 · 2019: 1 · 2016: 1 · 2015: 2 · 2014: 2 · 2013: 1 · 2012: 2
- FWCI
- 0.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Electrocardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- magnetocardiography, electrocardiogram, myocardial infarction, Q-wave myocardial infarction, body surface potential mapping, magnetic maps, ischemic heart disease, QRS complex, ventricular repolarization, inferior myocardial infarction, anterior myocardial infarction
- MeSH terms
- Coronary Disease, Electrocardiography, Female, Humans, Magnetics, Male, Middle Aged, Myocardial Contraction, Signal Processing, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complementary nature of electrocardiographic and magnetocardiographic data in patients with ischemic heart disease. https://app.cochat.ai/papers/10.1016/0022-0736(90)90121-h
- The paper
- Lant, J., Stroink, G., ten Voorde, B., Horacek, B. M., & Montague, T. J. (1990). Complementary nature of electrocardiographic and magnetocardiographic data in patients with ischemic heart disease. Journal of Electrocardiology. https://doi.org/10.1016/0022-0736(90)90121-h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.