Radiofrequency losses in NMR experiments on electrically conducting samples
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since sample dielectric loss depends strongly on frequency [6,8,29,9], the vast majority of sample heating occurs from RF irradiation at the 1 H frequency.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of Intracellular pH by 31P Magnetic Resonance
Moon, R. B., & Richards, J. H. (1973) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)43389-9 · Cited by 1,189
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Observation of tissue metabolites using 31P nuclear magnetic resonance
Hoult, D. I., Busby, S. J. W., Gadian, D. G., Radda, G. K., Richards, R. E., & Seeley, P. J. (1974) · Nature · doi:10.1038/252285a0 · Cited by 673
Self-citationThe NMR receiver: A description and analysis of design
Hoult, D. I. (1978) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(78)80002-8 · Cited by 426
Burt, C. T., Glonek, T., & Bárány, M. (1976) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)33527-5 · Cited by 339
Human erythrocyte metabolism studies by 1H spin echo NMR
Brown, F. F., Campbell, I. D., Kuchel, P. W., & Rabenstein, D. C. (1977) · FEBS Letters · doi:10.1016/0014-5793(77)80875-2 · Cited by 310
Contraction and recovery of living muscles studied by 31p nuclear magnetic resonance
Gadian, D. G., Dawson, M. J., & Wilkie, D. R. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011835 · Cited by 294
Self-citationPhosphorus nuclear magnetic resonance of perfused working rat hearts
Jacobus, W. E., Taylor, G. J., Hollis, D. P., & Nunnally, R. L. (1977) · Nature · doi:10.1038/265756a0 · Cited by 292
Phosphorus NMR studies on perfused heart
Garlick, P. B., Radda, G. K., Seeley, P. J., & Chance, B. (1977) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(77)91653-9 · Cited by 197
High resolution 31P nuclear magnetic resonance studies of intact yeast cells.
Salhany, J. M., Yamane, T., Shulman, R. G., & Ogawa, S. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.12.4966 · Cited by 160
Cited by
Macovski, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360327 · Cited by 420
Alderman, D. W., & Grant, D. M. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90123-9 · Cited by 320
Sensitivity of magnetic-resonance current-density imaging
Scott, G. C., Joy, M. L. G., Armstrong, R. L., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90310-4 · Cited by 248
Cell water dynamics on multiple time scales
Persson, E., & Halle, B. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709585105 · Cited by 217
“Thus, the NMR sensitivity deteriorates, because thermal ionic motion induces noise in the receiver coil (39), and the sample is heated by electrolyte friction induced by the electric component of the oscillating radiofrequency field (40).”
BackgroundRadiofrequency microcoils in magnetic resonance
G. Webb, A. (1997) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(97)00004-6 · Cited by 216
Metadata
- Authors
- Gadian, D. G., & Robinson, F. N. H.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1979-05
- Volume
- 34
- Issue
- 2
- Pages
- 449-455
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2066561387
- Cited by
- 172
- References
- 11
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.