Broadband heteronuclear decoupling
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coherent Averaging Effects in Magnetic Resonance
Haeberlen, U., & Waugh, J. S. (1968) · Physical Review · doi:10.1103/physrev.175.453 · Cited by 1,083
Advances in MAGNETIC RESONANCE
(1976) · High Resolution Nmr in Solids Selective Averaging · doi:10.1016/b978-0-12-025561-0.50001-0 · Cited by 956
Approach to High-Resolution nmr in Solids
Waugh, J. S., Huber, L. M., & Haeberlen, U. (1968) · Physical Review Letters · doi:10.1103/physrevlett.20.180 · Cited by 880
(1996) · NMR Spectroscopy Techniques · doi:10.1201/9781482273311-13 · Cited by 557
NMR population inversion using a composite pulse
Levitt, M. H., & Freeman, R. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90265-8 · Cited by 456
Self-citationNuclear Magnetic Double Resonance with an Incoherent Radio-Frequency Field
Ernst, R. R. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1727409 · Cited by 370
Compensation for pulse imperfections in NMR spin-echo experiments
Levitt, M. H., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90082-2 · Cited by 287
Self-citationLevitt, M. H., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90066-4 · Cited by 214
Self-citation
Cited by
MLEV-17-based two-dimensional homonuclear magnetization transfer spectroscopy
Bax, A., & Davis, D. G. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90018-6 · Cited by 3,597
An Improved Broadband Decoupling Sequence for Liquid Crystals and Solids
Fung, B. M., Khitrin, A. K., & Ermolaev, K. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1896 · Cited by 1,987
NMR techniques for quantum control and computation
Vandersypen, L. M. K., & Chuang, I. L. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.76.1037 · Cited by 1,217
“The remaining errors are further reduced for a properly chosen train of four pulses, X 2 X 2 X¯ 2 X¯ 2 , which performs markedly better than X 2 X¯ 2 X 2 X¯ 2 s Levitt et al. , 1982 d .”
BackgroundComputer-optimized decoupling scheme for wideband applications and low-level operation
Shaka, A. J., Barker, P. B., & Freeman, R. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90122-2 · Cited by 1,108
Self-citationAn improved sequence for broadband decoupling: WALTZ-16
Shaka, A. J., Keeler, J., Frenkiel, T., & Freeman, R. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90207-x · Cited by 1,039
Self-citation
Metadata
- Authors
- Levitt, M. H., Freeman, R., & Frenkiel, T.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1982-04
- Volume
- 47
- Issue
- 2
- Pages
- 328-330
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2050108671
- Cited by
- 394
- References
- 8
- FWCI
- 11.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.